Product Details

100MV Digital Signal Generator Analog Transmitter Source Simulator


VICTOR 71A l Signal Generator Current and voltage process calibrator Analog Transmitter Source Simulator


Description

This series of meters are categorized into the standard and thermocouple type. This manual is illustrated based on the thermocouple type.

This series of meters has the following functions:

  • 100 mV, 30 V DC voltage measurement, 20 mA DC current measurement, and switching value measurement;
  • 100 mV, 30 V DC voltage output, 20 mA DC current output and SIMULATE output;
  • V, mA manual step output,automatic waveform output;
  • Simultaneous display of V, mA and percentage;
  • Loop detection function: It simultaneously provides the 24 V loop power supply and measures the current.

The following functions are added to the thermocouple type:

  • Eight scale division (i.e., R, S, B, K, E, J, T and N) thermocouple measurement and output function;
  • Temperature display in Celsius degree and Fahrenheit degree;
  • Automatic and manual cold junction compensation function.

Open-package Inspection

Check the goods to see if they are damaged during delivery. Check if the goods are complete, and keep the packing materials for future delivery.

This meter comes with the following standard accessories:

• One pair of test leads (with alligator clips)

• One manual

• One 9 V alkaline battery (6LR61)


Technical Specification

General Characteristics

Display refresh2~3 times/second
Overload protection50mA/30V
Working temperature and humidity range0~40 ºC and a relative humidity below 85% (no condensation)
Storage temperature and humidity range-20 ºC~60 ºC and a relative humidity below 90% (no condensation)
Precision ensures the temperature and humidity range23±5ºC and a relative humidity below 75% (no condensation)
Temperature coefficient0.1 × basic precision/℃ (temperature range <18 ℃ or >28 ℃)
Ambient conditions for useIndoor and outdoor use (not waterproof), with an elevation of 0~2000 m
Outrange displayOL
Battery kind9V (6LR61) alkaline battery one
Power consumption

When alkaline battery is used

Loop current measurement and DC current output (SOURCE) 20mA (a load of 1000Ω): approx. 1000mVA

Other work function: approx. 300mVA

Low batteryDisplay battery sign
Automatic shutdownNo operation for about 15 min by default
Preheating time10 min
Close the meter enclosure for calibrationNo need for internal adjustment
Size147(L)×75(W)×42(D)mm
WeightApprox. 230 g
Calibration cycleOne year

Detailed Precision Index of Measurement

Measurement FunctionRangeMeasure RangeResolutionAccuracyNotes
DC voltage100mV-10.0mV~110.0mV100uV0.2%+4

• Input impedance: 30V: 300kΩ (nominal value)

mV:>1MΩ (nominal value)

• Common mode rejection: 50Hz or 60Hz >80dB

• Series mode rejection: 50Hz or 60Hz > 40dB

• Overvoltage protection:30V (peak to peak value)

30V-5.00V~30.00V10mV0.2%+4
DC current20mA0.00mA~22.00mA0.01mA0.2%+4

• Overload protection: 50mA/30V

• Load voltage: approx. 18mV/mA

ThermocoupleR0°C~1760°C1°C0.2%+4• Thermocouple measurement adopts ITS-90 thermometric scale,whose precision does not include error of the cold junction compensation, and the impact of thermoelectrical potential
S0°C~1760°C
B400°C~1820 °C
K-200°C~1370°C
E-200°C~1000°C
J-200°C~1200°C
T-200°C~400°C
N-200°C~1300 °C

Detailed Precision Index of Output

Output FunctionRangeOutput Setting RangeResolutionAccuracyNotes
DC voltage100mV0.0mV~110.0mV100uV0.2%+4• Maximum output current 1mA
10V0.00V~11.00V10mV0.2%+4• Maximum output current 5 mA (<10V)
DC current20mA0.00~22.00mA0.01mA0.2%+4• 20mA maximum load: 1KΩ

Analog transmitter

SIMULATE

-20mA0.00~-22.00mA0.001mA

• External power supply: 5~28V

• 20mA maximum load: 1KΩ

Loop power supply LOOP24V±10%• Maximum output current 25mA
ThermocoupleR0°C~1760°C1°C0.2%+4• Thermocouple measurement adopts ITS-90 thermometric scale,whose precision does not include error of the cold junction compensation, and the impact of thermoelectrical potential
S0°C~1760 °C
B400°C~1800°C
K0°C~1350°C
E0°C~700°C
J0°C~950°C
T0°C~400°C
N0°C~1300°C
Capacitive load≥0.01uF

Technical Data

ProjectVICTOR 71AVICTOR 71B
SOURCEDC millivoltRange0~110mV0~110mV
Basic accuracy0.2%+4dgt0.2%+4dgt
Resolution100uV100uV
DC voltageRange0 ~ 10V0 ~ 10V
Basic accuracy0.2%+4dgt0.2%+4dgt
Resolution10mV10mV
DC currentRange0~22mA0~22mA
Basic accuracy0.2%+4dgt0.2%+4dgt
Resolution0.01mA0.01mA
Sink currentRange0~22mA0~22mA
Basic accuracy0.2%+4dgt0.2%+4dgt
Resolution0.01mA0.01mA
External power supply5 ~ 28V5 ~ 28V
ThermocoupleRange8 types(R/S/K/E/J/T/B/N)
Basic accuracy0.2%+4dgt
Resolution1℃
MEASUREDC millivoltRange-10~110mV-10~110mV
Basic accuracy0.2%+4dgt0.2%+4dgt
Resolution100uV100uV
DC voltageRange-5~30V-5~30V
Basic accuracy0.2%+4dgt0.2%+4dgt
Resolution10mV10mV
DC currentRange0~22mA0~22mA
Basic accuracy0.2%+4dgt0.2%+4dgt
Resolution0.01mA0.01mA
Loop powerRange24V24V
Basic accuracy10%10%
Limit current25mA25mA
ThermocoupleRange8types(R/S/K/E/J/T/B/N)
Basic accuracy0.2%+4dgt
Resolution1℃
Other functionsManual Step Output
Automatic Waveform Output
Standard Quantity Per Carton12pcs12pcs
Standard Carton Measurement430mm*350mm*22.50mm430mm*350mm*22.50mm
Standard Carton Cross Weight7Kg7Kg

China 100MV Digital Signal Generator Analog Transmitter Source Simulator supplier

100MV Digital Signal Generator Analog Transmitter Source Simulator

Inquiry Cart 0