1. General

It is a handheld digital Clamp Meter with the measuring functions of ACA, ACV, DCV, Resistance, Frequency, Temperature and etc., it could be used in Lab, family and other circumstance, where high current measurement is required.


2. Safety Note

The instrument’s design meets the standard of IEC1010-1 (EN61010-1) pollution 2, CAT.600V and UL3111-1. Please read the following before operation.


3. General Property

3-1-1. Display: LCD display 3-1-2. Max Display: 3999 (3 3/4) digit automatic polarity Display.

3-1-3. Max Jaw Opening: 51mm 3-1-4. Over range Indication: “OL” Display.

3-1-5. Hold: Date Hold, Peak Value Hold 3-1-6. DCA Auto Zero Adjustment

3-1-7. Sampling Rate: 3tims/second 3-1-8. Low Battery Indication

3-1-9. Continuity Test: Buzzer sounds at less than (50±20) Ω. 3-1-10.Auto Range

3-1-11. Auto Power Off 3-1-12.Power Consumption: Approx. 3 mA

3-1-13. Power Supply: 1pc 9V battery (IEC6LF22, NEDA1604 or JIS006P)

3-1-14. Operation Environment: 0-40℃, Relative Humidity: <70% RH.

3-1-15. Dimension: 260mm x 100mm x 50mm

3-1-16. Weight: Approx. 330g (including battery)

3-1-17. Accessory: Operation Manual, Gift Box, Test Leads, Temperature Probe TP01, 9V battery.

3-2 Technical Property

3-2-1. Technical Specification

3-2-1-1. Accuracy: ±(a% x reading + dgts) at (23±5) ℃, relative humidity <70%.

3-2-1-2. Temperature coefficient: 0.1 x specified accuracy/1℃ (<18℃ or >28℃)


4. Technical Data: VICTOR 6056A+


Basic FunctionRangeAccuracy
DC Voltage400mV/4V/40V/400V±(0.5%+4d)
1000V±(1.0%+6d)
DC Current40A±(3%+8d)
400A±(2.5%+8d)
1000A±(3%+10d)
AC Voltage400mV±(1.6%+8d)
4V/40V/400V±(0.8%+10d)
750V±(1.0%+10d)
AC Current40A±(3%+10d)
400A±(2.5%+8d)
1000A±(3%+10d)
Resistance400Ω±(0.8%+5d)
4kΩ/40kΩ/400kΩ/4MΩ±(0.8%+4d)
40MΩ±(1.2%+10d)
Capacitance4nF±(3.5%+30d)
40nF/400nF/4uF/40uF±(3.0%+10d)
100uF±(5.0%+10d)
Frequency9.999HZ/99.99HZ/999.9HZ/9.999kHz/99.99kHz±(0.5%+4d)