Q235-A HVAC Fire Dampers 70 Degree Motorized Modulating Dampers

Q235-A HVAC Fire Dampers 70 Degree Motorized Modulating Dampers

Brand Name:SX
Certification:CE,ISO9001
Minimum Order Quantity:1 Set
Delivery Time:To be negotiated
Payment Terms:T/T; L/C
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Zhengzhou China
Address: Room 1308, Building 3, Yabao International Building, at the intersection of Jinshui East Road and Xinyi Road, Zhengzhou
Supplier`s last login times: within 22 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Fire hydrant

Manual HVAC fire damper , installed in the ventilation or air-conditioning systems, usually it is open, once fire occurs, the gas temperature of duct arrives at high degrees, and then the fuse protector will be fused and the damper will close under the pull of spring. It can meet the requirement of stability and completeness in a certain time. It can insolate smog and fire outside.


Mechanical dampers shut the cross sectional area of a duct in the event of a fire either by means of pivoting a fire-resistant board (in Europe), or by means of steel shutters, similar to blinds on a window (in North America). In the European designs, the turning mechanism is fully contained, permitting the dampers (subject to type approval) to be grouted in place, which permits a heat sink effect to conduct heat from an accidental building fire, which impinges upon a duct and damper, to be conducted into surrounding structures.


Fire damper performance parameter table
Serial numbernameperformance parameters
1Standard flange specificationsValve long side b or diameter D (mm)Flange side width (mm)
D≤28020
280≤D≤630,b≤63025
630<D1250,630<b≤125030
1250<D≤2000,1500<b≤250040
D>2000,2500<b≤400050
2Temperature sensorvalve static nominal operating temperature 70℃ (valve closes automatically)
3MaterialValve body2~3mmQ235-A
Bles2mm708-88 Cold rolled plate
AxshaftGB905-82 Cold pull round steel Ф12
Axft sleeveOil-containing metallurgical powder copper sleeve
4Local resistance coefficientResistance coefficient of ≤ 0.5 at full opening
5Paint treatmentGround floor rust proof primer (second floor), outer fire proof paint (medium ash steel paint)
6Rated voltageDC24V±10%
Rated current0.7A
Micro switchAC380V,3A
Torque10~70Kg.f/cm
Action modeautomatic, electric, manual or 70℃ to close the valve
7Fire control valveReset method (open state)Manual reset
Smoke and fire control valveManual reset
Smoke and fire damperManual reset
Remote control smoke and fire damperRemote control manual reset
Automatic reset fire damperElectric reset
8Air leakageIn the standard state, when the pressure difference on both sides of the valve is 500Pa after the valve is closed, no more than 700mm³/㎡/h