Home /Energy Meters /

0.05% 300V Energy Meter Calibration Equipment WIth PC Software

0.05% 300V Energy Meter Calibration Equipment WIth PC Software

Brand Name:HNMC
Model Number:MCSB-UTI
Minimum Order Quantity:1
Delivery Time:30-45 days
Place of Origin:China
Price:Negotiable
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000
Supplier`s last login times: within 38 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Portable Three Phase Meter Test System MCSB-UTI


Comprising Part

1) Standard Meter

2) Phantom Load Power Source

3) Test cables

4) Optical sensor

5) Communication cable

6) PC software

7) Power cord


Standard Meter


1) Small size and weight

2) Used in lab or worksite

3) Work as standard meter and calibrator in worksite or lab

4) LCD display

5) Accuracy class: 0.05 or 0.02 (optional)

6) Measuring range: 3*(1V-576V)/3*(1mA-120A)

7) Power and Energy test, Demand test, CT burden & Ratio Test, PT load test, Dial test

8) Optional for DC measurement for transducer test


Technical Index

Mains Supply Range45-450V, 45-65Hz
Power consumptionMax 20VA
Influence from external power supply on test result≤0.005% when change 10%
Working Temperature-10 °C….+50°C
Temp. Co efficiency

≤0.0025%/ °C +10°C to +40°C

≤0.0050%/°C -10°C to +50°C

Frequency range45…70Hz
Influence from external magnetize field≤0.07 % /0.5mT
Time base1-99s
Current Test

Direct mode


Range:1mA-120A

Display resolution: 6 valid digits

Measurement Error:

≤ ± 0.02% 10mA…120A

≤ 0.02% to 0.05% 1mA to 10mA

Clamp mode


Range:10A, 50A,100A,300A,500A,1000A, 3000A (optional)

Display resolution: 6 valid digits

Measurement error: ≤0.2%

Voltage Test
Range1V….560V
Display resolution6 valid digits
Measurement error

≤ ± 0.02% (30V…560V)


Burden Measurement

Voltage range0V…5V
Display range0.000mv…5.000v
Measurement error≤ ± 1.0 %

Power Measurement (active, reactive, apparent)
Error: ≤0.02% (40V~576V,10mA~120A,PF≥0.5, 2-21 Times Harmonic Wave)
DC Measurement
Range0 ..…± 20 mA0V …± 10V
errorE < ± 1.0%E < ± 1.0%
Display range0.00 mA…20.00 mA0.000V….10.000V
Energy Measurement Error

Active & apparent: 0.02% (direct mode) & 0.2% (clamp mode)

Reactive: 0.04% (direct mode) & 0.4% (clamp mode)

Power factor measurement
ErrorE ≤ ± 0.0002
Display range-1.00000….+ 1.00000
Resolution0.010
Frequency Measurement
Error±0.005%RD
Range40-70HZ
Display range40.0000HZ to 69.9990HZ
Harmonic content measurement
Times2 – 51times
Error±10%RD±0.1%

Standard Power Source

Technical Index

Model No.UTI-10UTI-100
Description1mA-12A, accuracy class 0.05 or 0.11mA-120A, accuracy class 0.05 or 0.1
Supply VoltageAC 85-282V, 47-63HZAC 85-282V, 47-63HZ
Power Consumption290VA450VA
Influence of auxiliary voltage≤0.005% at 10% variation≤0.005% at 10% variation
Dimension510*600*170mm510*600*170mm
Weight20KG27KG
Frequency Range45-69HZ45-69HZ
Frequency Resolution0.001HZ0.001HZ
Frequency ErrorLess than 0.01HZLess than 0.01HZ
Phase Angle Range0-359.99°0-359.99°
Phase Angle Resolution0.001°0.001°
Phase Angle Error0.1°0.05°
Communication PortRS232RS232
Range (P-N)30-300V30-300V
Power3*25VA3*30VA
Display ResolutionSix significant digitsSix significant digits
Output accuracy0.1%0.05%
Output stabilityBetter than 0.05%/2minBetter than 0.05%/2min
DistortionBetter than 0.5%Better than 0.5%
Range1mA-12A1mA-120A
Power3*25VA3*30VA
Display ResolutionSix significant digitsSix significant digits
Output accuracy0.1%0.05%
Output stabilityBetter than 0.05%/2minBetter than 0.05%/2min
DistortionBetter than 0.5%Better than 0.5%
Fundamental Frequency range45-69HZ45-69HZ
Range2-31st times2-31st times
Maximum content in both voltage and current circuit40%40%
Active power0.1%0.05%
Reactive power0.2%0.1%
Apparent power0.1%0.05%
Power factor0.1%0.05%
Voltage0.1%0.05%
Current0.1%0.05%
Phase0.1°0.05°

Features


1) Can be used independently or together with standard meter

2) With measurement mode selection namely 3P3W, 3P4W and 1P2W

3) Power Source (PS): output 0-360V/phase & 1mA-12A or 120A/phase, or depend on client requirement

4) Linear amplifier

5) Can be independent set & output of each phase voltage & current

6) Can set phase angle independently

7) Automatic control by PC software

8) Manual control by touch screen/keypad


System Features

1) Can be used in lab or worksite

2) Big LCD display, touch screen operation

3) Can test various types of single and three phase eletromechanical and electronic meter

4) Can test meter basic error, dial test, demand test, creep test, start test, CT ratio, CT burden, PT burden,

DC measurement (optional)...etc

5) Harmonic test 2-31 times (system)

6) Can test and display

a. True RMS value of voltage for each phase

b. True RMS value of phase to phase voltage

c. Harmonics distortion in each phase and total harmonic distortion

d. Phase current

e. Phase angle between voltages

f. Phase angle between voltage and current

g. Active, reactive and apparent power of each phase

h. Total power factor

i. Total active, reactive and apparent power

j. Instantaneous power factor for each phase

k. Frequency

l. Vector diagram

m. Hamornic analysis and spectrum

7) With enough protection in circuit design

8) User-friendly PC software




China 0.05% 300V Energy Meter Calibration Equipment WIth PC Software supplier

0.05% 300V Energy Meter Calibration Equipment WIth PC Software

Inquiry Cart 0