Cabinet Type CT PT Test Equipment System Error Measurement

Brand Name:HNMC
Model Number:MCHZDT-3Z
Minimum Order Quantity:1
Delivery Time:30-45 days
Payment Terms:L/C, T/T, Western Union
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

Cabinet Type CT PT Test Bench System MCHZDZ-3Z


System Configuration


1) HZDT Fully automatic Cabinet type Control Bench

2) Digital Transformer Tester

3) Current Transformer Burden (5A/1A optional)

4) Standard Current Transformer ( with Current Source)

5) Voltage Transformer Burden

6) Standard Voltage Transformer ( with Voltage Source)

7) Current Transformer Primary Testing Cable

8) CT & PT Secondary Testing Cable

9) PC Test software


Main Function

Ratio error and phase angle error test of CT & PT


Technical Parameter & Features

HES-10 CT&PT Test Bench

Input VoltageAC 220+/-10% 50HZ+/-0.5hz
Output voltageAC 0-250V
Rated Capacity25KVA
“Open-circuit demagnetization”, “Closed-circuit demagnetization”, “Error measurement”
Over current protection:>100A
FY current transformer burden,FY voltage transformer burden,HES-1C Digital Transformer Tester,Other Control function etc

Digital Transformer Tester

Voltage Range150V, 100V, 100/√3V (customization available)
Current range5A, 5A(S), 1A, 0.5A
Accuracy class2.0
Ratio error±0.0001% ~ ±19.99%
Phase error±0.01' ~ ±900'
Impedance0.001Ω~ 19.99Ω. Minimum resolution: 0.001Ω
Admittance0.001 ms ~ 19.99ms. Minimum resolution:0.001 ms
Rated frequency50 or 60HZ

Standard Current Transformer with current generator

Rated primary current(A)5-5000A
Rated secondary current5A or 1A
Accuracy class0.02%, 0.05%, 0.05S%, 0.01%, 0.005% (optional)
Rated secondary load0.2 ohm
Frequency50HZ
Operating Range1%--120%
Capacity of Current Source25kVA or more

Fully automatic Current transformer burden box

Rated Current5A, 1A
Operating Range1%--120%
Rated load (VA)2.5VA-60VA (customization is available)
Rate Frequency50Hz or 60HZ
Accuracy Class±3%
Power factor0.8, 1.0
Full automatic, three phases can be tested at the same

Fully automatic Voltage transformer burden box

Rated voltage100V, 100/√3V or more options
Operation Range20%--120%
Rated load1.25VA-80VA (customization is available)
Fundamental error±3%
Power factor0.8, 1.0
Rated Frequency50Hz or 60Hz

Standard Voltage Transformer with Voltage Generator


Rated primary voltage6kV,10kV,15kV,22kV,35kV or more option
Rated secondary voltage100V,100/√3V,110V,110/√3V, or more option
Accuracy class0.05% or higher accuracy class
Secondary capacity0.5VA or more option
Power factorcosΦ=1.0
Power frequency50HZ
Range of operating voltage20%--120%


China Cabinet Type CT PT Test Equipment System Error Measurement supplier

Cabinet Type CT PT Test Equipment System Error Measurement

Inquiry Cart 0