0.005 Class CT PT Test Equipment Integrated With Source

Brand Name:HNMC
Model Number:HLB-32G
Minimum Order Quantity:1
Delivery Time:30-45 days
Place of Origin:China
Price:Negotiable
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details

Standard Current Transformer HLB-32G series


Technical Parameter

Primary
Wound primary winding5….100A or 5….480A, 50/60HZ (more option available)
Applied primary

Applied primary: 100….3200A (1…10, maximum 12

turns) or 480A-3200A (1-2 turns) (more option available)

Rated Secondary

1A (model No.HLB-32G/1), 5A (model No.HLB-32G/5)

Or 1A&5A combined (model No.HLB-32G/1-5)

Test PrimaryA 2000 ampere-turn winding provided for self test of CT
Accuracy0.005%(or 0.002% as option)
Duty cycleContinuous upto 3200A, and 30 minutes or more at 4000A
Secondary winding design8Taps at 0, 100, 200, 1500, 1600, 2000, 2500, 3200 amperes to turns
Ratios available with customer applied primary winding100, 120, 125, 130, 140, 150, 160, 175, 180, 200, 225, 240, 250, 260, 280, 300, 320, 325, 350, 360, 375, 400, 450, 480, 500, 600, 625, 640, 650, 700, 750, 800, 900, 1000, 1200, 1250,1300, 1400, 1500, 1600, 1800, 2000, 2400, 2500, 3000, 3200A
Ratio available with pre-wound primary winding100, 90, 80, 75, 70, 65, 62.5, 60, 50, 45, 40, 37.5, 35, 32.5, 31.25,30,25, 24, 20, 18, 16, 15, 14,13,12.5, 12, 10, 9, 8, 7.5, 7, 6.5, 6.25, 6, 5, 4.5, 4, 3.75, 3.5, 3.25, 3.125, 3, 2.5
Rated secondary burden

5VA (model No.HLB-32G/5)

0.2VA (model No.HLB-32G/1)

5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A (model No.HLB-32G/1-5)

Power factorCOSΦ=1.0
Operating range(1%-120%)In
Frequency50/60HZ
Voltage levelAC 600V
Withstand voltage2000V 1min
Insulating mediumair
Dimension of feed through hole

Φ140mm


Size

Smaller one: Approx 590mm*400mm*240mm (design with applied primary 1-10, maximum 12 turns)

Bigger one: Approx 590mm*400mm*600mm (design with applied primary 1-2 turns)

Weightapprox 50kgs
Accessories3.5meters length secondary cable with connectors

Designs for optional


Features


1) More ratios to ensure good accuracy

2) 5 to 3200A current transformer design

3) Used for precision measurement of AC current or calibration of instrument current transformer

4) Can be installed on a bus bar can be used with a primary conductor consisting of turn numbers

5) Designed with a tapped primary & secondary windings to ensure a large number of ratios over

a range 5 to 3200A (or more as option)

6) Adopting “two stage principles” to ensure excellent accuracy and also allow to run long leads between

CT and load but not degrading CT accuracy.

7) Adopting advanced design technology to ensure that it can be used in severe magnetic environment

and also not affected by position of primary conductor in the hole or in the location of return conductor

8) With facility to test the performance of CT and verify its own accuracy.

9) CT ratio selection switch is optional and if customer need, it can be provided by adjust the design structure,

then can select mentioned CT ratios but no need changing secondary.


Note:


1) Also can offer standard current transformer integrated with source (3200A CT with 4000A & 8.8KVA source;

2000A CT with 2400A & 8.8KVA source)

2) Photo design mentioned in the brochure is as a reference, final design possibly will have change after

customer inform special & optional requirements.

3) If choosing bigger one design, customer can reduce a lot of time when applying turns.

China 0.005 Class CT PT Test Equipment Integrated With Source supplier

0.005 Class CT PT Test Equipment Integrated With Source

Inquiry Cart 0