CT PT TEST Equipment System HES-30


Configuration

Standard CT, ±0.01S%
Standard PT (6kV-38.5kV), ±0.05%
CT Burden (5A, 1A), ±3%
PT Burden (100V, 100/√3V, 100/3V), ±3%
PT Burden (110V, 110/√3V, 110/3V), ±3%
Transformer Tester (Calibrator), ±2%
Current generator
Voltage Generator
Secondary Test Cables
PC Test Software
CT PT Test Control Bench

Technical Parameter


HES-30 CT/PT Test Control Bench


Input Voltage:AC 220V±10%, 50Hz, Single-Phase
Input Current:AC 0-120A
Rated Capacity:30kVA
Output Voltage:AC 0-250V
Output Current:AC 0-120A
Output Voltage Adjustment:Provided the Coarse adjustment & Fine adjustment
Protection function:Provided over current & overvoltage protection
Output conversion functions:Connect to Current source / Voltage source conversion functions
The Bench Structure:Horizontal structure
Power Indicator:LED, Output current, Output voltage
Color of the Bench7035 Gray

HES-1Bx Transformer Tester

Measure item:Ratio errors & Phase errors of the CT and PT
Rated current:5A, 1A
Rated voltage:100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V
Multiplier:1/√3, 1/3, 1, 1.5, 2
Accuracy class:±2%
Operation range:(1%-120%).In, (20%-120%).Un
Frequency:50Hz or 60Hz
Ratio error range:±0.0001% ~ ±19.99% (3 ranges: 0.1999%, 1.999%, 19.99%).
Minimum resolution:0.0001%.
Phase error range:0.01' ~ ±900' (3 ranges: 9.00', 90.0', 900')
Minimum resolution: 0.01'
Impedance range:0.001Ω~ 19.99Ω.
Minimum resolution: 0.001Ω.
Admittance range:0.001 ms ~ 19.99 ms.
Minimum resolution:0.001 ms.
Alarm Function:Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent.

Input Load:

- On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0

- On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0

- On Standard PT secondary side: ≈0.05VA (100V)

Communication Interface:Provided the RS232 serial PC communication interface
Display model:LCD
Power supply:AC 220V±10%, 60Hz
Power consumption:< 20VA
Product Type:

Portable type


CT Burden FY47-49


Rated Current:5A, 1A

Power Factor

and Rated Burden:

In=5A:

COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

(more option available)

In=1A:

COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

(more option available)

Accuracy Class:±3%
Operation Range:(1%-120%). In
Frequency:50Hz or 60Hz
Withstand Voltage:2kV/1min
Insulation:Air
Operating Model:Short-time (Used in CT Accuracy Testing System)
Product Type:Portable type.

High-current Test Cables of the CT

Cables includes: 3000A(600mm2) x 3m x 2pcs, 1000A(200mm2) x 5m x 1pc

500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pcs


HLB-50G1 Standard CT



Rated Primary Current(A):

5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3500, 4000, 4500, 5000A

(more option available)

Rated Secondary Current:5A, 1A
Rated Current Ratio:5A~5000A/5A, 5A~5000A/1A (more option available)
Accuracy Class:0.01S% (0.05%, 0.02%, 0.01% or better are available)
Rated Secondary Burden:0.2Ω (Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A)
Power Factor:COSΦ=1.0
Operating Range:(1%-120%). In

Connection Mode:

Fixed connection terminals at Pri.current range is 5A-450A

Pass-through connection with 2 turns at Pri.current range is 500A-900A

Pass-through connection with 1 turn at Pri.current range is 1000A-5000A

Frequency:50Hz or 60Hz
Voltage Level:AC 600V
Withstand Voltage:2000V 1min
Insulating Medium:Air

SLQ-30KVA Current Generator


Input Voltage:AC 0-250V
Output Current:AC 0-5000A
Rated Capacity:30kVA
Rated Input Current:AC 120A
Frequency:50Hz or 60Hz
Current Output Model:

Fixed terminal at current is 50A, 200A, 500A

Through-hole connection at current is 500A-5000A

Products Shape:Stainless Steel Box
Working condition:0 - 40ºC, RH ≤ 90%

FY95-1 PT Burden

Rated Voltage:100V, 100/√3V, 100/3V
Power Factor:COSФ=0.8, COSФ=1.0
Rated Burden (VA):

1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 50VA, 80VA, 100VA

(more option available)

Total Output Burden:308.75VA (more option available)
Accuracy Class:±3%
Operation Range:(20%-120%). Un
Frequency:50Hz or 60Hz
Withstand Voltage:2kV/1min
Insulation:Air
Operating Model:Short-time (Used in PT Accuracy Testing System)

HJB-35G3 Standard PT

Rated Primary Voltage:6kV, 10kV, 15kV, 22kV, 35kV, 38.5kV
Rated Secondary Voltage:100V,110V,100/√3V,110/√3V,100/3V,110/3V

Rated Voltage Ratio (kV):

6/0.1, 6/√3/0.1/√3, 6/√3/0.1/3, 6/0.11, 6/√3/0.11/√3, 6/√3/0.11/3

10/0.1, 10/√3/0.1/√3, 10/√3/0.1/3, 10/0.11, 10/√3/0.11/√3, 10/√3/0.11/3

15/0.1, 15/√3/0.1/√3, 15/√3/0.1/3, 15/0.11, 15/√3/0.11/√3, 15/√3/0.11/3

22/0.1, 22/√3/0.1/√3, 22/√3/0.1/3, 22/0.11, 22/√3/0.11/√3, 22/√3/0.11/3

35/0.1, 35/√3/0.1/√3, 35/√3/0.1/3, 35/0.11, 35/√3/0.11/√3, 35/√3/0.11/3

38.5/0.1, 38.5/√3/0.1/√3, 38.5/√3/0.1/3, 38.5/0.11, 38.5/√3/0.11/√3, 38.5/√3/0.11/3

Accuracy Class:0.05% (100V,110V,100/√3V,110/√3V), 0.1% (100/3V,110/3V)
Rated Secondary Burden:0.2VA(110V, 100V), 0.07VA(110/√3V, 100/√3V), 0.02VA(110/3V, 100/3V)
Power Factor:COSΦ=1.0
Operating Range:(20%-120%). Un
Frequency:50Hz or 60Hz
Insulation:Epoxy resin casting