Add to Cart
Multiple Optional Functions, Meet the Personalized Needs
■Integrated sound & light alarming device, split-type sound & light
alarming device,
24V DC stabilized voltage power supply.
■Wireless transmission
①It is possible to transfer data wirelessly to the cell phone,
remote monitoring center, monitoring computers and other monitoring
equipment, which will utilize the upper-level host to realize the
functions of data analysis, storage, printing or the like on the
computer.
■ Pretreatment system
①Room temperature and high humidity pretreatment system
②High temperature and high humidity pretreatment system
③High temperature and high humidity and high dust pretreatment
system
■Accessory for connection with computer for monitoring
①Free upper-level host software, RS485 / RS232 converter
②For laptop without RS232 interface, USB / RS232 converting and
connecting cable is needed, if the network transmission is needed,
TCP / IP converter will be further needed.
■Installation type accessories optional
①wall mounting bracket;
②mounting clips for fixation on the pipes (1/2", 3/4" pipe);
③stainless steel threaded welding seat or flange to be installed on
the pipeline (it is necessary to mark the flange or pipe size, such
as DN50, DN15 ...);
④Rain cover;
⑤24VDC or 220AC sampling pump (sampling distance is 10 m);
⑥vacuum pump (sampling distance is greater than 40 m);
⑦24V switching power supply;
⑧pressure reducing valve;
⑨flow meters.
| Detection Gas | EX, Toxic gases, oxygen, carbon dioxide, flammable and explosive gases, TVOC, etc. |
|---|---|
| Range | 0~1, 10, 100, 1000, 5000, 50000 ppm (mg/m³); 0~100% LEL; 0~200 mg/L; 0~20%, 50%, 100% VOL; Custom ranges available |
| Dimensions | 210*170*85mm (L*H*W) |
| Weight | 1.8 Kg |
| Installation | Pipeline Type or Wall Mounting |
| Display | 1.7-inch high-definition color screen |
| Environment | Temperature: -40℃ ~ +70℃ Humidity: ≤10 ~ 95% RH (regular) |
| Approvals | IP65; Exd Ⅱ CT6 |
| Power Supply | 12-30VDC (standard 24V), DC stabilized voltage switching power supply of 1A or greater |
| Accessories | Manual, qualification certificate, warranty card, outer packaging box |
| Optional Items | Alarms, Wireless Transmission, Pretreatment System, SD Card, Temperature/Humidity Measurement, Computer monitoring accessories |