Zetron OPC-L3 Chemtrac Oil Particle Counter Stable Performance

Brand Name:Zetron
Model Number:OPC-L3
Minimum Order Quantity:1 pcs
Delivery Time:14 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Room 20E, Block 1-A, Oriental Ginza, No. 48 Dongzhimenwai Avenue, Dongcheng,100007, Beijing, China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

OPC-L3 Oil Particle Counter


OVERVIEW

OPC-L3 oil particle counter is an upgraded product on the basis of OPC-L2, which is based on GB/T 18854-2002 (ISO11171-1999) and other standards.

Adopting the counting principle of photo-resistive (shading) method, it fully conforms to the corresponding national standard and international standard.

It can provide fast, accurate, reliable and repeatable test results and complete pollution monitoring and analysis report.

FEATURES

· Laboratory model with Win10 or higher
· The operating system is extremely compatible and modernized, and can be installed on tablets, laptops or desktop computers
· More than a dozen different standards can be output at a time, support tester report personalized signature
· Built-in temperature collection, built-in water content detection, water activity collection, built-in viscosity detection wireless access to the office network, comes with unlimited database storage, customized standards unlimited addition of calibration curves unlimited additions


  1. Adopt the light blocking (shading) counting principle established by the International Hydraulic Standards Committee
  2. High-precision laser sensor with wide test range, stable performance, low noise and high resolution
  3. The high-pressure injection pump sampling method is adopted, the sampling volume can be set by yourself, the injection speed is stable, and the sampling accuracy is high
  4. The positive and negative pressure combined sampling system can achieve sample degassing, suitable for testing products with different viscosities
  5. Built-in pressure sensor, you can directly set the pressure value and automatically determine the air pressure in the cabin to ensure safety
  6. Built-in air purification system to ensure the test is not contaminated
  7. Built-in SAE4059E, SAE4059F, SAE4059F-CPC, NAS1638, ISO4406, GB/T14039, GJB-420A, GJB-420B, ГOCT17216-71, DL/T1096, SAE749D, JBT9737.1, QC/T29104-201, DL-T432-2018, HH005-2018 and other commonly used standards. It supports adding custom standard tests at will and there is no upper limit on the number of custom standards added. The required standards can be set according to customer needs.
  8. Built-in data analysis system, one test can provide all standard test data and contamination levels
  9. Built-in multiple calibration curves, compatible with all commonly used domestic and international standards, for single-channel or multi-channel fully automatic calibration
  10. The particle size can be set arbitrarily, and nearly 10,000 particle sizes are built-in to facilitate particle size analysis
  11. A variety of sampling containers such as standard sampling bottles or sampling cups can be used to meet the testing requirements of different industries
  12. Optional viscosity, dielectric constant, moisture and temperature sensor modules to achieve multi-parameter testing
  13. Windows operation interface, built-in database, unlimited data storage, can be used for retrieval and query by test standard, sample name, sample batch number, tester, test time, etc.
  14. Multi-level account authority management, account authority can be set separately, and digital signature is supported
  15. One control system supports multiple sensor settings, and the system control software can be installed on a tablet, laptop or desktop computer.
  16. The test results can be printed using a micro or desktop printer, exported to PDF, Excel and other formats, and can be transmitted via USB, WiFi, etc.
APPLICATION SCENES


OPC-L3 oil particle counter can be widely used in aviation, aerospace, electric power, petroleum, chemical industry, transportation, port, metallurgy, machinery, automobile manufacturing and other fields.

PRODUCT PARAMETERS

ModelOPC-L3
Light sourceSemiconductor laser
Particle size range0.8μm~600μm (calibrated according to 1~100um or 4~70um(c))
Detection channels64 channels (Editable channels), the particle size can be set by the user
Sensitivity0.8μm (ISO4402) or 3μm(c) (GB/T18854, ISO11171)
Resolution<10% (GB/T18854, ISO11171)
RepeatabilityRSD<2%
Sample detection viscosity≤650cSt (viscosity is too large can be combined with heating or dilution method detection)
Sampling volume0.2~6000mL, interval 0.1mL
Sampling accuracybetter than ± 0.5%
Sampling speed5 ~80mL/min
Pneumatic chamberPositive and negative air pressure chamber device, to realize sample degassing and high viscosity sample detection
Maximum vacuum of air
pressure chamber
-0.08Mpa
Maximum positive pressure of
air pressure chamber
0.8 Mpa
Maximum particle concentration12000~40000 particles/mL
Power supply110~245V AC, 50Hz, 70W
Overall Dimension340mm*310mm*730mm
Net weight22kg





China Zetron OPC-L3 Chemtrac Oil Particle Counter Stable Performance supplier

Zetron OPC-L3 Chemtrac Oil Particle Counter Stable Performance

Inquiry Cart 0