NEO Photo-Ionization Detectors
OVERVIEW
The NEO is one of the most advanced handheld VOC (Volatile Organic Compound) monitors available for ppb(parts per billion) detection. VOCs include a variety of chemicals such as benzene, alcohols, fuels, paint thinners,industrial solvents and many others, which can have short and long-term adverse health effects. Measuring these compounds is essential for worker protection in industries like oil & gas, fire & hazmat, pharmaceuticals, paints & adhesives, and many others. In addition, VOC monitoring is useful chemical process control, detecting leaks and other releases to the environment, and in measuring indoor air quality. The NEO offers several models from the most sensitive 1 ppb to a high range up to 15,000 ppm for different applications, and a filter tube version (NEO BENZ) for benzene-specific or butadiene-specific measurements. In addition to the standard continuous read-out, a Leak Detection and Repair (LDAR) mode is included. Novel designs of the Photo-ionization Detector (PID) and Ultraviolet (UV) lamp provide outstanding sensitivity, stability and reproducibility. Includes real-time data monitoring using mPower Suite software via cable to a PC or via Bluetooth to an Android phone or tablet.
FEATURES
• Smaller and lighter weight than comparable PIDs
• Most stable ppb-level PID on the market
• Outstanding linearity over full measurement range
• Easy charging on laptop or other USB port
• USB Micro Charger; combination USB-m charging and communications cable
• Powerful battery (run time 24 hours)
• Bluetooth Low Energy (BLE) connectivity standard
• Search Mode for LDAR Sampling
• Filter tube version for benzene- or butadiene-selective measurements
• Large backlight graphic display
• Lamp glow indicator
• Rugged, stainless-steel housing with rubber outer boot
PRODUCT PARAMETER
Size9.06 x 3.15 x 2.36 in (230 x 80 x 60 mm)
Weight24.69 oz (700 g)
SensorPhoto-ionization sensor with standard 10.6 eV lamp (9.8 eV lamp in MP186 NEO BENZ)
Response Time t90
  • 3 seconds for VOCs
  • 45 seconds with Benzene filtering tubes
Accuracy±3% (at calibration point)
Battery / Run TimeRechargeable Lithium-Ion battery with 24 hours typical operation
Keypad4 operation keys
Sampling pumpBuilt-in pump @ 450 cc/min, settable to low flow of 250 cc/min
Sample from up to 150 ft (45 m) horizontally or vertically
Display128 x 128 graphical LCD, 1.77 x 1.73 in (45 x 44 mm), with LED backlight for enhanced display readability
Direct ReadoutReal-time reading of gas concentration (ppb, ppm, mg/m3, μg/m3)
PID measurement gas and correction factor, lamp on/off, Man-Down alarm on/ off, battery status, pump status, datalogging on/off, wireless on/off, temperature and time
AlarmAudible (90 dB @ 30 cm), visual (flashing bright red LEDs), and on-screen indication of alarm conditions plus wireless remote alarm notification
High, Low, STEL, TWA alarms
Over range alarm, battery low alarm
Man-Down alarm with pre-alarm and real-time remote wireless notification
EMI/RFIHighly resistant to EMI/RFI
Compliant with EMC Directive 89/336/EEC
IP RatingP-66/67
DataloggingStandard 12 months at one-minute intervals
Storage interval: 1 to 3,600 seconds (adjustable)
CalibrationTwo/three-point calibration
Charging and CommunicationCharging, data download, instrument setup and firmware upgrades on PC or laptop via Micro USB
Wireless data and alarm status transmission via built-in RF modem
Wireless Range1,000 ft (300 m) typical
Correction FactorsIntegrated Correction Factor list of more than 700 compounds
Safety CertificationsUL/cUL: Class I, Div 1, Group A, B, C, D
T4, -20°C ≤ Tamb ≤ +50°C (pending)
Temperature-4° to 113°F (-20°C to 50°C)
Humidity0% to 95% relative humidity (non-condensing)
AttachmentsDurable rubber boot, color coded for different models; Tube holder for MP186 NEO BENZ
Warranty2-year warranty including 10.6eV lamp and sensor; 1-year on 9.8eV lamp

Model NumbersVOC Range (ppm)Resolution (ppb)
MP181 (NEO PPM)500010
MP182 (NEO EXT)1500010
MP184 (NEO PPB)150001
MP185 (NEO SEMI) (w/o MicroUSB)150001
MP186 (NEO BENZ)
(w/9.8 eV Lamp & Tube Holder)
200 Benzene or Butadiene50
10,000 VOC5

APPLICATION SCENES

1.Industrial Hygiene

2.Oil & Gas

3.Benzene-Specific Measurements

4.Environmental Testing

5.Fire & Hazmat

6.Paints, Adhesives & Printing

7.Degreasers

8.Fumigants

9.Heat Transfer Fluids

10.Industrial Solvents

11.Ammonia

12.Pulp Mills

13.Indoor Air Quality (IAQ)

China Portable Zetron Neo Photo Ionization Detector Ip 67 supplier

Portable Zetron Neo Photo Ionization Detector Ip 67

Inquiry Cart 0