Four In One Portable Multi Gas Detector Catalytic Combustion Sensor Similar Honeywell Alert

Brand Name:Zetron
Certification:CE
Model Number:MS104K
Minimum Order Quantity:1 set
Delivery Time:1-10 work days
Payment Terms:T/T, Western Union, MoneyGram, D/P, D/A, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Room 20E, Block 1-A, Oriental Ginza, No. 48 Dongzhimenwai Avenue, Dongcheng,100007, Beijing, China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Portable Multi Diffusion Type
Gas Detector

OVERVIEW

· It can be used in: rapid detection of a variety of gas concentration and measurement of environmental
temperature and humidity, if the measurement exceeded the limit value, the alarm will emit sound & light vibration as alarm.

· Suitable for detecting the concentrations of gases in the atmosphere environment in the pipeline or confined space.

The types of gases for detection are more than 500 types.



FEATURES & BENEFITS

1. Multi-gas made simple, easy to wear, slim and compact
It is possible to simultaneously detect 1 ~ 4 types of gases, and the units can be switched freely .
Units that can be selected: PPM, mg/m3, Vol%, LEL%, PPHM, ppb, mg/l.


2. Compact design, easy to use
Handy and durable, the MS104 is intuitive to operate single-handedly using three function keys.
The easy-to-read color display clearly lays out all the information for you.


3. Large Data Storage Management, release and documentation in no time
Standard configuration is the data storage capacity for 100, 000 entries.
Real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored.
It is supported to use the local host to view, and delete data, and upload the data via USB interface to the computer for data analysis or printing.RS485 communication is an optional configuration.


4. Clear signaling design
The signal system of the MS104K is based on a clear color code: sound & light alarm, vibration alarm, display screen visual alarm.These are also documented in the data logger.

5. Economical Calibration Management
The deviation of the concentration which was detected out by the instrument from the standard gas concentration can be corrected by calibrating the concentration or changing the display coefficients.

6. Inductive charging protects against wear and tear
This makes it easier to operate and increases the lifespan of the device.
Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at the same time.



SPECIFICATION

Gases to be detected

Arbitrary combination of 1 ~ 4 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on.

Optional configuration: temperature and humidity measurements.

Application scenariosAll the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.
Detection range0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/l, 100%LEL, 20%, 50%, 100%Vol can be selected; and other ranges can be customized.
Resolution

0.01ppm or 0.001ppm (0 ~ 10 ppm);

0.01ppm (0 ~ 100 ppm),

0.1ppm (0 ~ 1000 ppm),

1ppm (0 ~ 1000 ppm or more),

0.01 mg/l (0 ~ 200% mg/l),

0.1% LEL,

0.01%Vol,

0.001% Vol

Detection principleElectrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, and so on, depending on the type of gas, range, field environment and user demand.
Sensor service lifeElectrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; infrared principle: 5 ~ 10 years; catalytic combustion: 3 years; thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years.
Maximum allowable error≤±3% F.S (higher precision levels can be customized)
Linearity≤±2%Linearity≤±2%Linearity≤±2%
Response timeT90≤30 secondsRecovery time≤30 seconds
Sample gas temperature-40 ℃ ~ + 70 ℃, and the optional configuration of high-temperature sampling and cooling filter handle will be possible to detect the smoke gas at the temperature of 400 ℃ or higher.
Temperature and humidity measurementOptional configuration: temperature at -40 ℃ ~ + 70 ℃, accuracy level at 0.5 ℃; humidity at 0 ~ 100% RH, precision level at 3 % RH
Power supply3.7VDC, 3000mA high capacity rechargeable polymer battery
Display mode2.31-inch high-definition color screen
Detection modeDiffusion type measurement. The calibrated flow rate is 500 ml/minute.
Alarm modeIt is possible to set as sound & light alarm, vibration alarm, sound & light + vibration alarm, turning off the alarm.
Communication interfaceUSB (charging and communication), optional: RS485 communication interface
Data storageStandard configuration is the data storage capacity for 100, 000 entries
Protection levelIP65
Explosion-proof typeIntrinsically safe type
Explosion-proof markExia II CT4 Ga
Exterior dimensions130×68×34mm (L×W×H)
Weight200g
Standard accessoriesManual, qualification certificate, warranty card, USB charger (including the data cable), belt clip, colorful packaging box (optional high-grade aluminum instrument case)

APPLICATION

The detector is widely used in petroleum, chemical industry,environmental protection, metallurgy, refining, gas, biochemical medicine, agriculture, fire protection, Archaeology and other industries and places that need safety monitoring for toxicity and harmfulness, explosion prevention.


China Four In One Portable Multi Gas Detector Catalytic Combustion Sensor Similar Honeywell Alert supplier

Four In One Portable Multi Gas Detector Catalytic Combustion Sensor Similar Honeywell Alert

Inquiry Cart 0