Neware 5V12A 8 Channel Battery Cycler Pouch Polymer Cells Tester

Neware Battery Charge and Discharge Test System , ranging from μA single cell applications up to 1MW packs , is a high precision system designed specifically for testing lithium ion battery cells , modules , packs and capacitors . It is suitable for product development, quality control , and helpful to characteristic research , cycle life testing , product screening, and quality assessment .

Software Feature
1 , Windows - based software interface for easy operation .
2 , Uses standard SQL data - base management .
3 , Real - time monitoring windows and integrated graph / data windows can set various working modes for measuring capacity and cycle life of all types of rechargeable batteries , such as constant current discharge , constant current charge , constant voltage charge , rest , as well as voltage , current , time , capability , negative voltage slope , and other limit conditions .
4 , The user can define the curve by different types such as voltage - time curve , current - time curve , capacity - voltage curve ,
loop times - charge / discharge capacity curve , loop times - charge / discharge efficiency curve , etc . to make curves be compared both by visually and statistically .
5 , Provide timely instructions , warnings , and intelligent support .
6 , Compliance CE Certified .

HPPC , Capacity , Cycle Life , Formation and Grading , Over - charge , Over - discharge

Market - proven Testing System
Less than 20ms Response Time to Meet Rapidly Changing Power Requirements
0.1 percent Full - scale Accuracy for Current and Voltage
10Hz Data Acquisition Frequency , 100Hz Optional
500ms Minimum Pulse Width More Than 1 Million Records Can Be Processed


PowerPer Channel Output Power30W
Stop currentRange 1 , 2mA Range 2 , 12mA Range 3 , 24mA
Stability0.1percent of FS
TimeCurrent Response Time1ms
Data RecordingRecord ConditionMin Time - 100mS
Min Voltage - 10mV
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA
Record Frequency10Hz
ChargeCharge ModeCCCharge , CVCharge , CCCVCharge , CPCharge
End ConditonVoltage , Current , Relative Time , Capacity , -deltaV
DischargeDischarge ModeCCD , CPD , CRD
End ConditionVoltage , Current , Relative Time , Capacity
PulsechargeCCC , CPC
DischargeCCD , CPD
Min Pulse Width500ms
Automated SwitchAutomated swith from charge to discharge for each pulse
End ConditionVoltage, Test Time
CycleLoop Measure Range65535 times
Max Steps Per Loop254
Nested LoopNested loop Function , Max Support 3 Layers