Neware Battery Capacity Discharge Tester Echelon Utilization Battery Recovery


a . BTS4000 is very possibly the correct choice for you to get to know Neware and her battery test products better .

Till year 2017 , 90percent new customers of Neware would choose BTS4000 as a starting point , its really the time - proven and reliable choice .


b . Due to the rapid data acquisition frequency , BTS4000 could be applied to super capacitor or EDLC - Electronic Double Layer Capacitor test . Through our advanced software , the capacitance , DCIR - Direct Current Internal Resistance could be easily calculated .


c . Higher Accuracy . More Cost - effective . We believe it can improve your battery test .


d . Neware Battery Charge and Discharge Test System , ranging from uA single cell applications up to 1MW packs , is a high precision system designed specifically for testing lithium ion battery cells , modules , packs and capacitors . It is suitable for product development , quality control , and helpful to characteristic research , cycle life testing , product screening , and quality assessment .


Recycle Battery Function


a . If you have recovery battery pack , like Toyota Prius battery pack - generally , each piece has 6 single NiMH cell , then several pieces batteries assembed in one pack , and you need to check each single cell for capacity , cyclie life , resistance , etc . Then assemble the battery cell after sorting by capacity , resistance . You will get the new battery pack . And last you will test the battery pack to check the real capacity and other function parameter .


Voltage and Current - the Very Essential


b . The accuracies of Voltage and / or current may fundamentally affect the results come from a test . Thats why accuracies of voltage and current are so important to a battery tester .


c . Neware battery testers provide good accuracies both for voltage and current . This ensures you get the most reliable data from your tests .


d . A measurement system can be accurate but not precise , precise but not accurate , neither , or both . Neware battery testers provide good prrecision meanwhile . To get an overall performance of a measurement system , Measurement system analysis MSA is usually introduced for the study .


Input Power425W
Channel FeaturesConstant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure
Channel Control ModeIndependent Control
VoltagePer Channel Voltage Range1.5V - 5V
Accuracy0.05 percent of FS
CurrentPer Channel Current RangeRange1 , 5mA - 1A Range2 , 1A - 6A Range3 , 6A - 12A
Accuracy0.05 percent of FS
Stability0.05 percent of FS
Data RecordingRecord ConditionMin Time - 100mS
Min Voltage - 10mV
Min Current - Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA
Record Frequency10Hz
PulsechargeCCC , CPC
DischargeCCD , CPD
Min Pulse Width500ms
Automated SwitchAutomated swith from charge to discharge for each pulse
CycleLoop Measure Range65535 times
Max Steps Per Loop254
Nested LoopNested loop Function , Max Support 3 Layers
ProtectionSoftware ProtectionPower - down Data Protection
Off - line Testing Function
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time
Per Unit Main Channels No.8
Dimensions3U , 480 – 330 - 180mm