Metal Nut Screw 24VDC Thermal Circuit Breaker Manual Reset Single Pole

Brand Name:Tian Rui
Certification:CUL UL TUV CCC VDE
Model Number:91 Series
Minimum Order Quantity:1000PCS
Delivery Time:5-7 Days
Payment Terms:D/P, T/T,Paypal, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Building C, Xinmeijia Science and Technology Park, Chashan
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

91 Series Electronic Metal Nut Screw 24V DC Manual Reset Mini Thermal Single Pole Circuit Breaker


Technical Data


Current rating range0.5~10A
Input voltage rating125/250VAC;50VDC
Interrupting Capacity125/250CACx1,000A(UL 1077)
Typical Life1,000 operations at 200% overload
Insulation co-ordinationRated impulse withstand voltage 2.5kV
Dielectric Strength>1.500VAC/min
Insulation Resistance>100MOHM (DC 500V)
Degree of protectionTerminal area IP00,operating area IP40


How to Select the Current


Generally, it is recommended to choose about 1.5 times the rated current. For example, if the rated current is 1A, and the actual abnormal current fluctuation reaches 1.5A, 1.5A is appropriate; if the abnormal current reaches 2A, 2A is appropriate. The time of tripping (that is, disconnection) is determined by exceeding the selected A number. If the actual current exceeds the greater, the faster the trip will be. It is not immediately disconnected after exceeding the selected A number. The specific trip time is as follows:


Calibration(at25℃)

100%of Rated CurrentHold,No Trip
150%of Rated CurrentTrip Within 1Hour
175%of Rated Current2.0-10.0 sec Trip
200%of Rated Current1.1-5.0 sec Trip


Approval


Approval & File NORated currentRated voltage
CUL UL E1551590.5-10.0A125/250VAC;50VDC
TUV SUD B1501586110060.5-10.0A125/250VAC;50VDC
CCC 2011010307520581.0-10.0A125/250VAC
VDE 400361601.0-10.0A125/250VAC

Max.Internal Resistance
1.0- 2.0Amp0.175 Ohm
2.1-3.0Amp0.125 Ohm
3.1-3.7Amp |0.050 Ohm
3.8-5.0Amp0.040 Ohm
5.1-7.0Amp0.030 Ohm
7.1- 10.0Amp0.020 Ohm


Mechanical/Environmental Data


Operating Ambient Temperature: -10℃ to +60℃ Mounting: Various options. See Ordering Information and drawings
Termination: 250’’(6.35mm)quick connects or solder terminals


Product Life


The number of mechanical actions is more than 3000 times, and the current impact of 6 times is more than 50 times.


Wiring Mode


Regardless of the positive and negative poles, just like a switch, the end is in and the end is out, that is, in series, the pins can be welded or 2.8MM plug springs can be used.


Typical Applications


Tarnsforms, Motors, Battery chargers, Power supplies,
appliances, extra low voltage systems, machinery.






The Difference Between Automatic Reset and Manual Reset


After the over-current protector is tripped (disconnected), manual reset (on) requires the actual current to be reset within the selected current by pressing the button. For automatic reset, the actual current will automatically reset within 60 seconds of the selected current. There is no button for automatic reset, no head, 91 series are manual reset.