Home /Health Care Products /

Peripheral Vision Test Equipment For Scientific Research / Clinical Use

Peripheral Vision Test Equipment For Scientific Research / Clinical Use

Brand Name:SYSEYE
Certification:TUV
Model Number:BIO-1100
Minimum Order Quantity:1
Delivery Time:5 working days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Chongqing Chongqing China
Address: 2nd floor of building #5, 27 Fengsheng Road, Jinfeng Town,High-Tech Industrial Development Zone, 401329 Chongqing, People's Republic of China
Supplier`s last login times: within 28 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

peripheral vision test equipment For scientific research, teaching, and clinical use

The Visual Field Analyzer (BIO-1000/BIO-1000-Plus) instrument belongs to the category of medical examination equipment. It is an important means to determine the development of glaucoma, optic chiasm damage, neurological disease, toxic amblyopia, retinal disease, choroidal disease and other diseases by alignment the change of visual field. This product For scientific research, teaching, and clinical use. Perimeter is suitable for auxiliary diagnosis of glaucoma.

Specification
Testing scope90°
Testing distance30CM
Background lightwhite31.5asb,yellow315asb
Visual target0.08asb---10000asb(0-51DB)
Target sizeGoldmannⅠ, II ,III,IV,V
Visual target stimulation time200ms
Visual target interval timeStandard and custom
Threshold policyMacula,10-2,24-2,30-2,60-4,nasal side
Upper threshold policyC-40,C-64,C-76,FF-81,FF-120,FF-135……
Special detection strategyEsterman monocular,Esterman binocular,upper36°screening,blind point testing
Yellow-blue testingStandard 440nm blue visual target + 315asb OG530yellow background brightness
Visual targetRed ,blue
Dynamic policyStandard dynamic,blind dynamic,dark spot dynamic ,straight line dynamic
Custom policyStatic custom dynamic custom
Pupil size measurementAuto
Fixation monitoringPhysiological blind spot monitoring,eye position monitoring,eye position moving alarm,eye tracking curve
Environment light testingAuto
Analysis softwarereliability analysis , single report, triple report, GHT glaucoma semi vision report, GPA glaucoma developing analysis, VFI analysis, Blue-yellow analysis
SystemWin7 above
Others
Size412mm(length)* 497mm(width)* 513mm(height)
Wight17kg
Power

100-240V HZ:50-60Hz


Feature of Perimetry Test Machine
* Strictly implement international high standards in technology.
* The database is very rich and complete, identifying more subtle early visual field defects.
* It is easier to diagnose glaucoma by analyzing the half vision of glaucoma.
* GPA analysis of glaucoma progression was upgraded, and mild glaucoma developed significantly.
Perimetry Test Machine features the followingEasy operation
 Touch screen design speeds data input.
 Menu and icon commands simplify operation.
 On-screen video eye monitor is standard on all models.
 Confirmation screens reduce unintentional data loss.
A keyboard and trackball or mouse can be connected to the Visual Field Analyzer as optional
datainput devices.

Perimetry Test Machine other feature
* Scientific intelligent interactive detection strategy, 30 ° It only takes 3 minutes to detect the range visual field.
* Simple one-stop modular software design, equipment operation learning only takes 2 minutes
* the same function of Zeiss Humphrey 860
* Halogen projection system: the stimulating light source comes from the broadband visible spectrum, which fully meets the stimulation of color cone cells.


The instrument should also be placed away from direct sunlight.

  • To ensure smooth operation, install the instrument on a level floor free of vibrations.

Also, do not place anything on the instrument.

  • Connect all cables properly before using.
  • Use the power at rated voltage.
  • When not in use, switch off the power source and apply the rubber cap and dust cover.



Company Introduction

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

























China Peripheral Vision Test Equipment For Scientific Research / Clinical Use supplier

Peripheral Vision Test Equipment For Scientific Research / Clinical Use

Inquiry Cart 0