White Blue Orange Silica Gel Dehydrating Breather of Transformer

Product Description

Whenever an electrical power transformer is loaded, the temperature of the transformer insulating oil increases, consequently the volume of the oil is increased. As the volume of the oil is increased, the air above the oil level in conservator will come out. Again at low oil temperature; the volume of the oil is decreased, which causes the volume of the oil to be decreased which again causes air to enter into conservator tank.
The natural air always consists of more or less moisture in it and this moisture can be mixed up with oil if it is allowed to enter into the transformer. The air moisture should be resisted during entering of the air into the transformer, because moisture is very harmful for transformer insulation. A silica gel breather is the most commonly used way of filtering air from moisture.
Silica gel breather for transformer is connected with conservator tank by means of flange.

Construction of Silica Gel Breather


The silica gel breather of transformer is very simple in the aspect of design. It is nothing but a pot of silica gel through which, air passes during breathing of transformer. The silica gel is a very good absorber of moisture. Freshly regenerated gel is very efficient, it may dry down air to a dew point of below -40oC. A well maintained silica gel breather will generally operate with a dew point of -35oC as long as a large enough quantity of gel has been used. The picture shows a silica gel breather of transformer.


ModelD (mm)H (mm)Silica Gel Wight (kg)Transformer Capacity of Oil (kg)Applicable Transformer Capacity (reference value)
XS2-0.2801700.2700Below 80KVA
XS2-0.5902000.51500Below 200KVA
XS2-112026013500Below 630KVA
XS2-1.51203001.55000Below 2000KVA
XS2-212033027000Below 3150KVA
XS2-3165355310000Below 10000KVA
XS2-5165450522000Below 50000KVA
XS2-101656801035000Below 500000KVA

Features

  • Very good absorber of moisture
  • Freshly regenerated gel is very efficient
  • Dry down air to a dew point

FAQ

Q1: What is your MOQ?

A: Our MOQ is 1 piece.

Q2: Do you offer sample?

A: Yes, we can provide you a sample.

Q3: What is your payment term?

A: 100% TT in advance.

Q4: What is your lead time?

A: 3-10 work days after order confirmed. Urgent need please discuss with us to find a way out!

Q5: Are you a manufacturer or a trader?

A: We are a manufacturer and all the items mentioned are made by ourselves. We have our own sales team to provide you the best export service too.

Q6: Can you make the packing and logo as customer request?

A: Yes we can.

Product picture



China Transformer Dehydrating Breather Desiccant wtih Blue Silica Gel 3kg supplier

Transformer Dehydrating Breather Desiccant wtih Blue Silica Gel 3kg

Inquiry Cart 0