Product Details
B Type RCCB Residual Current Circuit Breaker DC ELCB 2P 63 Amp 30mA
Type B 10KA RCD
- Residual current circuit breakers RCCBs are the safest devices for
detecting and preventing the tripping of leakage currents, thus
ensuring protection against electric shocks caused by indirect
contact.
- These devices must be used in series with MCBs or fuses to protect
them from the potentially damaging thermal and dynamic stress of
any overcurrent.
- They can also be used as the main disconnecting switch upstream of
any derived MCB.
- The main purpose of the RCCB is to provide protection against
direct and indirect contact with people or livestock, as well as
possible fire, from shocks caused by electrical leakage, which can
be fatal.
Technical Data
Mode | Electromagnetic |
Type(wave form of the earth leakage sensed) Rated current In | 63A |
Poles | 4P |
Rated voltage Ue | 4P 415V~ |
Insulation voltage Ui | 500V |
Rated frequency | 50/60Hz |
Rated residual operation current(I△n) | 30mA |
Rated residual operating current(I△dc) | 6mA |
Rated residual making and breaking capacity (I△m) | 500A(In≤40A), 10In(In>40A) |
Short-circuit current Inc= I△c | 10,000A 10000 |
Break time under I△n Rated impulse withstand voltage(1.5/50) Uimp | ≤0.1s 4000V |
Dielectric test voltage at ind.Freq. for 1min | 2.5kV |
Electrical life | 2,000 Cycles |
Mechanical life | 4,000 Cycles |
Installation
Contact position indicator | Yes |
Protection degree Ambient temperature(with daily average≤35℃) | IP20 -5℃~+40℃ |
Storage temperature | -25℃~+70℃ |
Terminal connection type | Cable/Pin-type busbar/U-type busbar |
Terminal size top/bottom for cable | 35mm2 18-3AWG |
Terminal size top/bottom for busbar | 35mm2 18-3AWG |
Tightening torque | 2.5Nm 22In-lbs |
Mounting | On DIN rail EN60715(35mm) by means of fast clip device |
Connection | Power supply in both directions |
Tripping Current Range
Lagging Angle 0° | I△n>0.01A 0.35I△n≤I△≤1.4I△n | I△n≤0.01A 0.35I△n≤I△≤2I△n |
90° | 0.25I△n≤I△≤1.4I△n | 0.25I△n≤I△≤2I△n |
135° | 0.11I△n≤I△≤1.4I△n | 0.11I△n≤I△≤2I△n |
RCD Protection
- This device is very important in electrical wiring installations as
a life protection device against electric shocks. Other circuit
breakers can only detect overcurrent and short-circuit faults, but
not leakage.
- This is why the RCCB is very important, only this device can detect
electrical leakage, which can cause injury or death to people and
can lead to the risk of fire. When designing your distribution
panel board, please ensure that this device is included in our
planning of the installation.
- Protection in case of indirect contact (indirect protection of
persons) and fault protection when disconnection is caused by an
impermissibly high touch voltage caused by a short circuit in an
exposed conductive part.
- Protection in case of direct contact (direct protection of persons)
- disconnection as additional protection in case of direct contact
with live conductors. If the device has a rated residual current of
In - 30 mA, dangerous inrush currents are disconnected within a
short time.
Certification:TUV