Home /Electrical Wires /

1kV Wind Turbine Cables Insulated Chloroprene Tough Rubber Sheathed Cable VDE

1kV Wind Turbine Cables Insulated Chloroprene Tough Rubber Sheathed Cable VDE

Brand Name:AHJR
Certification:GB/T9330-2008, GB/T12706-2008, GB/T19666-2005
Model Number:Wind Turbine Cables
Minimum Order Quantity:100meters
Delivery Time:5-8 working days
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Hefei China
Address: 1506-1507,BLOCK B,TIMES CITY ,669 BAOHE AVENUE , BAOHE DISTRICT ,HEFEI 
Supplier`s last login times: within 12 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Wind Power Rubber Insulated Chloroprene Rubber Sheath Cold Resistant Flexible Cable


Description:

This product is suitable for wind turbine generator system middle turbine and the installation of fixed tower or similar systems with twist resistant environment, can adapt to different weather conditions and special occasions, and has the characteristics of use in the cold, high temperature and high humidity in special environment.

Special cable for wind power generator in addition to meet the performance of ordinary cable, also must meet the basic requirements of small bending radius, frequent torsion, the wind power generator cable used in climate condition is bad, commonly used in China's northern region, the climate was cold, and the larger temperature difference between day and night, so the cable must also meet the environment the temperature of -45ºC to 50ºC, running temperature conditions for -40ºC and 50ºC.


Technical performance:

1. The conductor shall comply with the requirements of fifth kinds of soft round stranded conductors specified in GB/T 3956-2008
2. The highest operating temperature of Conductor: ethylene propylene rubber insulation 70ºC, 90ºC; silicone rubber insulation 90ºC.
3. The finished cable shall be to withstand the normal temperature torsion test and the low temperature torsion test specified in Appendix B of GB/T 29631-2013.
4. The finished cable shall be able to withstand weight test as specified in Appendix C of GB/T 29631-2013.
5. The finished cable shall be able to withstand the low temperature bending test specified in Appendix D of GB/T 29631-2013.


Specification:


product description

cable for wind turbine

Conductor Material

copper

Type

wind turbine cable

Certificate

CE,VDE

Rated Voltage

0.6/1KV

Color

customized color

Package

wooden drun

Conductor

copper

Jacket

PVC

Insulation material

PVC

FAQ:


1. Q: What we specialize in?

A.Disposable sterile syringe /needle, BCG AD syringe, disposable infusion set, disposable transfusion device, disposable venous transfusion needle etc.


2. Q:Can I have a sample first ?

A:Sure!Samples are available and free with certain QTY,if not,we'll charge accordingly.But the express fee need to paid by your esteemed company.


3. Q: What is delivery time?

A: It depends on your quantity.


4. Q:What is terms of payment?

A: T/T is the acceptable business way.


5. Q: Can I visit your factory?

A: Sure, warmly welcome.Please try to contact our sales representative first by email or phone. We will make the appointment and the most reasonable planning for you.


6. Q: What's the shipping way?

A: Regarding the small quantity order, we can send them by Fedex,DHL, express and the large quantity goods are shipped by ocean shipping according to client's demands.


7. Q: Do you provide OEM/ODM Service ?

A:Yes,please Send your requirements in details,we provide custom-make service to meet different needs of global clients with different budgets.


China 1kV Wind Turbine Cables Insulated Chloroprene Tough Rubber Sheathed Cable VDE supplier

1kV Wind Turbine Cables Insulated Chloroprene Tough Rubber Sheathed Cable VDE

Inquiry Cart 0