Row-Based Cooling Unit for Data Center Server Complete Cooling Solution

Product Introduction


COOLNET Row Cooling Precision Air Conditioning is an ideal product for inter-column cooling in green data centers. It has the industry's best cooling efficiency. The variable frequency scroll compressor uses environmentally friendly refrigerant R410A. It has excellent intelligent control and performance. Flexible cooling capacity design: can be used in 20%~100% adjustment of cooling capacity, which greatly improves the energy efficiency of ordinary air-cooled units by 33.3%~50%. The 7-inch touch screen can comprehensively display various data in the computer room and related working conditions of the unit


Advantages


Efficient EC fan system

  • Saving 20%-30% energy compared to traditional AC motor
  • Soft-startup function, Low startup current
  • Adjust rotary speed automatically according to cooling requirments and airflow pressure,and provide airflow required
  • N+1redundancy configuration of fans, ensure the airflow in case of any fan fault
  • Easy-maintenance designed

Options

  • Transfer switch for Dual Power Input
  • GPRS SMS alarm
  • Low-temperature startup kits
  • Wired Temperature/humidity sensors
  • Tree-way water valv

Electronic Expansion Valve

  • Adjust the throttle of valve smoothly to save the energy
  • Wide range og operations, which can help reduce the superheat degree and improvde EER
  • Realize cooling capacity and heat load precise matching
  • Qucik response, realize the precise cooling


Air Supply Method



Technical Parameter


ModelCRA013CRA025CRA040CRA050CRA060
Air SupplyFront/SideFront/SideFront/SideFront/SideFront/Side
Power Supply380Vac/3Ph/50Hz380Vac/3Ph/50Hz380Vac/3Ph/50Hz380Vac/3Ph/50Hz380Vac/3Ph/50Hz
Technical Data
Cooling Capacity (kW)13.226.742.653.363. 9
Sensible Cooling (kW)13.226.742.653.363. 9
Compressor
RefrigerantR410AR410AR410AR410AR410A
Quantity11111
Fan
Fan TypeEC centrifugal fanEC centrifugal fanEC centrifugal fanEC centrifugal fanEC centrifugal fan
Quantity45233
Air Volume (m3/h)3200500088001100012500
Heater
Heat TypePTCPTCPTCPTCPTC
Capacity (kW)23666
Class11111
Humidification
TypeElectrode type
Capacity (kg/h)11.5333
Air FilterG4G4G4G4G4
Connection Pipe
Humidifier inlet pipe (in)G1/2G1/2G1/2G1/2G1/2
Drain Pipe Φ (mm)2519191919
Gas Pip Φ(mm)15.8819.0519.052222
Liquid Pipe Φ (mm)9.5212.715.8819.0519.05
Indoor Dimension-L*D*H (mm)
Dimension300*1200*2000
300*1400*2000
300*1200*2000
300*1400*2000
600*1200*2000600*1200*2000600*1200*2000
Weight (kg)190230285310330
Note:
Standard working conditions: indoor return air dry bulb temperature 37°C, relative humidity 24%, outdoor dry bulb temperature 35°C ;