Easy To Install Power Distribution Unit Horizontal Installation

Brand Name:COOLNET
Certification:CE,ISO,ROHS
Model Number:Smart series PDU
Minimum Order Quantity:1unit
Delivery Time:15 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Easy-to-install power distribution unit unit


Product Introduction

Intelligent monitoring PDUs are complete and versatile, and can meet the needs of high-end server rooms and data centre software intelligent power distribution and environmental monitoring systems. Intelligent PDUs can monitor both current, voltage, electrical energy, power factor, carbon emissions, fuse status, surge effectiveness and other data. It can also monitor temperature, humidity, flooding, access control, human body sensing, etc. through sensors. Remote control via CP/IP, SNMP and other protocols Power on/off, sequential power on/off, threshold alarm management, authority management, a good helper for power management. Intelligent solutions allow users to Enable power distribution to be embedded into the server room dynamic loop management system. More precise and effective monitoring of energy consumption, equipment operation control and monitoring of the server room environment.


Advantages

Its advantages are mainly manifested in: more reasonable design arrangement, stricter quality and standards, long safe and trouble-free working time, better various leakage, over-current and overload protection, frequent plugging and unplugging actions and not easy to damage, small thermal rise, and more flexible installation It is convenient and suitable for industrial customers who have strict requirements on electricity consumption. It also fundamentally eliminates the safety hazards such as frequent power outages, burns, and fires caused by poor contact and small loads of common power strips.



Parameter


PDU


Parameters


input

Input typeAC single phase, AC three phase,-48VDC,240VDC,336VDC
Input mode

Transparent open type junction box,power cord, cable,

industrial connector, socket etc.

Input voltage range100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC
AC input frequency50/60Hz
total load currentMAX 63A

Output

Storage temperature-40 - +70
Relative humidity5-95% (No condensation)
Atmospheric pressure70kPa - 106kPa
Working altitudeNo more than 4000M

Environmental

Working temperature-10 - +75
Storage temperature-40 - +80
Relative humidity5-95% (No condensation)
Working altitudeNo more than 4000M
IP ratingIP20
Protectioninput protection moduleCircuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output protection moduleCircuit breaker, fuse box, fuse(optional)

Functional module

  • overload protection

  • slide circuit breaker

  • replaceable lightning protection

  • open junction box

  • current voltmeter

  • fuse

  • master switch

  • intelligent temperature control detection module


Certification


Case


Factory