Energy Efficient Operation Modular Data Center Space Saving

Brand Name:COOLNET
Certification:CE,ISO
Model Number:CYA,M08,CR012
Minimum Order Quantity:1set
Delivery Time:20-40 days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Green And Energy Efficient Operation With Modular Data Center Space Saving


Product Introduction

Coolnet modular standardized data centers are designed with a standardized, modular architecture, meaning that infrastructure investments do not need to be made in one step when building the physical infrastructure of the data center, saving initial investment costs. Avoiding one-time investment in infrastructure such as cooling, power supply and racks takes up a lot of money and can result in idle resources. Instead, the data center of the required scale can be deployed only according to the current business needs, and then expanded as the business needs develop, and cooling, power supply, racks and other equipment can be invested in phases, greatly reducing the initial construction costs.


Benefits


Features


1. Customized hardware facilities to improve cost performance.

Modularized network architecture, customized servers, micro-modules and their infrastructure according to specific business deployment.


2,Factory prefabrication, on-site assembly, and rapid deployment.

Standardization and productization of components, high quality control and clear engineering interface.


3,Change the cooling method.

In row cooling to meet the requirements of medium and high power density server rooms (5-12kW/rack).

Proximity cooling, channel closure. Energy transfer in close proximity, cold and heat isolation, total energy consumption of the server room is reduced by 10%.

Can be based on IT cabinet requirements, server room area and power density and other factors, the flexibility of a variety of unit components organically assembled together to achieve a standard, balanced micro-module composition design, and can be customized according to the specific project situation, very flexible.


4,Cold pool and inter-row cooling

Composed of two columns of equipment units facing each other, plus the channel closure components, skylights, side doors, etc. itself to achieve cold and hot channel isolation.

The inter-column air supply distance is short, the refrigeration system control strategy is highly accurate, and it can also achieve flexible cooling on demand, while this approach supports high-density loads.


5,Comes with uninterruptible power supply system

Internal integrated UPS or 240V DC and battery uninterruptible power supply system. Different micro-modules can be powered by different power supply systems to achieve a variety of power supply forms mixed in the same room.


6,Easy disassembly and assembly

Prefabricated by the factory, with industrial and standardized features, can be easily disassembled and assembled. The construction time is short and the construction site is easy to manage.


Air Supply Method

Technical Specification


Equipment SystemItemParameter
SystemDimension1200mm enclosed cold/hot aisle dual-row cabinets
1200mm enclosed cold/hot aisle Single-row cabinets
Rack QuantityDual Row Racks:≤48,Single Row Racks:≤24
RackDimensions600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
Protection ClassIP20
Enclosed AisleSkylight300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and DistributionDimension600mm(W)*1200mm(D)*2000mm(H)
UPS Power Supply380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
Battery40AH~240AH/12V Valve Regulated Lead Acid Battery
CoolingIndoor Unit Size300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
Cooling CapacityCooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
Power Supply3Phase 380VAC,50Hz
Air SupplyFront Supply
TypeEnclosed Hot/Cold Aisle
ProtectionIP20
Monitoring SystemMonitoringTemperature and humidity, smoke detection, smart access control, camera, water leakage alarm
Equipment monitoringPower supply, battery, power distribution, air conditioning