Smart Power Distribution Units 12 Way With Master Switch

Brand Name:COOLNET
Certification:CE,ISO,ROHS
Model Number:PDU3s60XD1-2E12G
Minimum Order Quantity:1 unit
Delivery Time:15 days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Smart Power Distribution Unit 12 Way With Master Switch


Product Introduction

PDUs are often referred to as the power distribution outlets of the cabinet. A PDU is a product designed to provide power distribution to electrical equipment installed in a cabinet. When high-power devices are ubiquitous, their operation is limited due to sockets. Messy wiring will bring a lot of potential safety hazards to the computer room, and the intelligent PDU has overload and power-off protection, which can prevent the current overload and cause the wire to catch fire and other disasters, and can solve these safety hazards to a great extent.

Technical Features

  • Manage large numbers of distributor power usage simultaneously
  • Provide SNMP MIB, network management system directly integrated monitoring
  • With overload and power-off protection, it can prevent disasters such as wire fire caused by current overload
  • Ultra-thin volume, can be used with various cabinets
  • Remote control of each group of socket switches and restarts
  • Provides LED indicators to show whether the distributor socket is powered
  • Support boot sequence to start the power supply


Parameter


PDU


Parameters


input

Input typeAC single phase, AC three phase,-48VDC,240VDC,336VDC
Input mode

Transparent open type junction box,power cord, cable,

industrial connector, socket etc.

Input voltage range100-277VAC/312VAC-418VAC/11VDC-240VDC/-43VDC- -56VDC
AC input frequency50/60Hz
total load currentMAX 63A

Output

Storage temperature-40 - +70
Relative humidity5-95% (No condensation)
Atmospheric pressure70kPa - 106kPa
Working altitudeNo more than 4000M

Environmental

Working temperature-10 - +75
Storage temperature-40 - +80
Relative humidity5-95% (No condensation)
Working altitudeNo more than 4000M
IP ratingIP20
Protectioninput protection moduleCircuit breaker, lightning protection, leakage protector, temperature insepction module (optional)
Output protection moduleCircuit breaker, fuse box, fuse(optional)