Integrated Rack Data Center With Rack Mounted UPS And Precision Air Conditioners


Product Introduction

COOLNET Rack Data Centers refer to an integrated data center solution for small business or server rooms, including uninterrupted power supply, smart power distribution unit, cooling system, monitor system and so on. It can be used as a micro data center which has the advantages of low cost and high efficiency.


Feature

Cooling System

1. The rack mounted precision air conditioners have the range of 3.5-10.5kw coolong capacity with inverter compressor and EC fan, which can reduce PUE value.
2. General N+X redundant for PAC can be group controlled in order to reduce operation and maintenance work.


Uninterrupted Poweer System

1. Including 3-30KVA capcity of UPS with the backup power from 15 minutes to 2 hours.
2. Industrial-grade devices, built-in C-level lightning protection
3. Comprehensive monitoring, real-time power display


Application

  • Edge Computing
  • As a computing node in remote and branch offices(Banks, Telecommunication companies, etc.)
  • As a floor distributor
  • In small business and enterprises

Technical Parameter


ModelEC08EC12EC20ERx
Power3KVA3-6KVA6-30KVA
Number of cabinets0.8m high cabinet, available space 8U1.2m high cabinet, available space 16UStandard 42U cabinet, free space 30U2-10 standard 42U glass door cabinets
Enclosed cabinetGlass door, IP5X, full cold and hot channel sealing
Power supply220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
RefrigerationUnique air duct design, without air conditioner and outdoor unitRefrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring