ISO Containerized Data Center , Mining Shipping Container

Brand Name:COOLNET
Certification:CE ISO
Model Number:ICDC20
Minimum Order Quantity:1 unit
Delivery Time:25days
Payment Terms:L/C, , T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

ISO Containerized Data Center,Mining Shipping Container

Product Introduction

In contrast to the traditional data center construction mode based on the building body, the container-level data center takes the commercial standard container as the carrier of the data center and integrates all systems such as cabinets, power distribution, refrigeration, integrated wiring, monitoring and management, fire protection and security, etc. It adopts the production mode of factory prefabrication and pre-commissioning, transports the container as a whole to the deployment site by land or sea, and then builds it on site in the way of "building blocks".

Advantange


  • Can be customized according to customer's requirements
  • Provide similar data center friendly operation environment
  • Any hardware manufacturers products can be integrated
  • Global maintenance standard integration
  • Extensible modular solution that allows to expand in the future
  • Focus on security (anti invasion, waterproof, fire prevention, and electromagnetic, etc.)Energy efficiency (PUE according to design will be as low as 1.2)
  • Lower TCO
  • Can be used in indoor and outdoor (including oil and gas fields, desert, etc.)
  • Cabinet maximum power for 10 kw/rack
  • The PUE of HP container data center can be lower than 1.25, and due to the adoption of FreeCooling technology, the PUE value can be reduced to 1.07.


Features

Modularization

A large number of modular components in the factory to complete, reduce the workload of the site construction, shorten the construction cycle of data centers;

Intellectualization

Intelligent monitoring system, greatly improve the reliability of the equipment, reduce the number of maintenance personnel, reduce the workload, and improve maintenance efficiency;


The high initial cost and using cost of traditional data centers cannot meet the massive growth of data processing in information technology society. Standardized ICDC products greatly reduce the cost of data center construction and operation and maintenance.

Technical Parameter

PRODUCT PARAMETERSICDC-20ICDC-20
Container Size20’HQ40’HQ
Rack Specification600*1000(1100)*2000mm600*1000(1100)*2000mm
Single Rack Capacity42U42U
Rack Quantity4PCS8-10PCS
Single Rack Capacity3-10KW3-10KW
IT Equipment Total Capacity12-30kw24-75KW
UPS25kva*2 N+1 modular UPS25kva*4 N+1 modular UPS
Battery back up time5-15mins5-20mins
CoolingIn-row air conditionerIn-row air conditioner
Monitoring systemYESYES
Door Security SystemYESYES
Fire alarm and gas fire extinguishing systemYESYES
Video Monitoring SystemYESYES
EPOYESYES
TransportabilitySupportSupport
StackableSupportSupport
ApplicationOutdoor TypeOutdoor Type
Diesel Generator ModuleExtrapositionExtraposition