Rack Type Precision Air Conditioner for rack servers and blade servers (3.5KW -9KW )


Product Introduction

COOL RACK Series rack-mounted air conditioner is a cabinet-level temperature control product specially designed for integrated cabinets data center, modular data center or high heat density data centers. It can be placed in the cabinet close to the heat source and can accurately handle the output of the equipment in the cabinet. The high sensible heat can effectively prevent the generation of local hot spots, reduce the return air distance, increase the return air temperature, and improve the energy efficiency ratio.


Benefits


Features

1. Supply the air closely, cooling the heat equipment directly, and more efficient for the cooling effect; close cold & hot channel, reduce energy loss, save energy consumption, and to create economic value for the user.

2. Can choose environment friendly refrigerants with variable frequency compressor and control system, control the cabinet temperature with accurate and intelligent, thus can achieve environment protection and social benefits.

3. With large range of cooling capacity, our planning products include fixed frequency compressor system: 3.5kw, 5kw and 9kw cooling capacity, inverter compressor and control system corresponding to 1-9kw adjustment capacity to meet the existing cabinet cooling needs and a single cabinet integration is getting higher and higher, the heat of growing trend war.

4. Variety installation methods, flexible choosing:

Split cabinet installation (CI**):Suitable a cabinet which have free space inside the cabinet, the indoor air conditioner installed inside the cabinet directly, do not take up external space, to ensure that the cabinet looks cleaning and beautiful.

Integral cabinet top installation (CT**): suitable for the cabinet that has relatively compact layout, the air conditioner installed in the top of the cabinet, and supply air cooling directly to the cabinet, do not take up internal space, can be installed other equipment as well, but must consider the cabinet’s height and the ventilating heat dissipation around the cabinet.

Integral cabinet side installation (CS**): Installed on the side of the cabinet, open a pore side of the air conditioner, and supply air to the cabinet. And the air conditioner is an integral type structure, no need to connect the pip for the installation site, but it must need good ventilation conditions since the condensation heat releasing around the cabinet.

5. The air conditioner configured after bending centrifugal fan, large air volume, small air enthalpy difference, high SHR air supply, suitable for server cooling characteristics;
6. High reliability, high lifespan;

Well-equipped, adopt well-known brand for fan, compressor, refrigeration accessories; multi-fan configuration, easy for replacement and maintenance.
7. All-weather operation, supply cooling annual, operating ambient temperature: -45℃~45 ℃;

8. With RS485 communication and monitoring functions;


Scope of Application

  • Micro Data C enter
  • Single row cabinet
  • Modular Computer Rooms
  • Medium and high heat density computer room
  • Modular Data Center
  • IT Rack for Blade Servers

Air Supply Method


Indoor Unit Parameters

Model-CJA0003000500070012
Phase/Function1.5P,Single Phase2P,Single Phase3P,Single Phase5P,Single Phase
Parameters
Cooling capacity kW3.557.512.5
Sensible cooling capacity kW 3.557.512.5
Air volume m³/h800115016002300
Sensible heat ratio %100100100100
Heating kW (Option)1123
Maximum operating current A15152534
Power Cord Cable Specificationsmm 3×2.53×2.53×43×6
Indoor/outdoor unit shut-off valve
Refrigerant gas pipe φ mm12.712.712.715.88
Refrigerant liquid pipe φ mm9.529.529.529.52
Indoor unit structural parameters
Dimension:W×D×H mm442×714×175 (4U)
442×714×218 (5U)
442×714×218 (5U)442×714×351 (8U)442×714×440 (10U)
Outdoor Unit
Type-CJT3005300530083013
Quantity1111
Note 1: Under standard conditions, the indoor dry bulb temperature is 37°C, the wet bulb temperature is 21°C, and the outdoor dry bulb temperature is 35°C;
Note 2: The above table is only part of the parameters, the specific configuration is subject to the actual purchase of the nameplate.

Outdoor Unit Parameters

Type- CJT3005300530083013
Power supply220Vac/1Ph/50Hz
InstallationVertical
Speed modeStepless speed regulation
Noise dBA54555658
Rated current A661015
Power Cord Cable Specificationsmm 4×1.54×1.54×2.54×4
Communication cable specificati mm (with shielding function)on 3×13×13×13×1
Structural parameters of outdoor unit
Dimension:W×D×H mm840×285×610840×285×610880×360×800930×390×1270

① The power cord of the outdoor unit must be connected from the indoor unit;
②The ex-factory unit is not equipped with a 4.3-inch touch screen, and needs to be purchased separately.