SEV SEVI Polarity Nonpolarity High Voltage DC Contactor 10A 20A 30A 50A 100A 150A 200A 250A 300A For Electric Vehicle

Brand Name:AMPFORT
Certification:CCC number 2019010304167727
Model Number:SEV10/SEVI10
Minimum Order Quantity:50pcs
Delivery Time:10 workdays
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.1, Yixiang ,Liwu Industrial Park,Liwuyuan Village,Xihu District, Shilong Town,Dongguan 523325,Guangdong ,China
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

SEV SEVI Polarity Nonpolarity High Voltage DC Contactor 10A 20A 30A 50A 100A 150A 200A 250A 300A For Electric Vehicle


Product Features


1.Full seal construction and high safety

2.Coil voltage:12VDC and 24VDC

3.Small size and high switching power

4. Full sealed inside by epoxy encapsulation technology to insure coil and contactor against being oxidized for long time

5.Use permanent magnet to eliminate electrica arc,high reliability

6. Implementation criteria:GB/T 14048.4-2010

7. Certification: CCC number 2019010304167727


Application


Mainly used in high voltage main circuit,pre-charge circuit,slow charging circuit,fast charging circuit,high voltage auxiliary system of electromobile,as well as high voltage main circuit system in charging pile,power control system of wind power,photovoltaic


Outline And Dimensions


Coil Operating Voltage


ItemNorminal Voltage12VDC24VDC
1Max. Voltage16VDC28VDC
2Max Pickup(close) Voltage9VDC18VDC
3Min Dropout(open) Voltage1.0VDC2.0VDC
4Coil Current267mA133mA
5Coil Power(20℃)3.5W3.5W
6Coil Resistance(20℃) ±5% Ohm45180

Peformance Parameter


TypeParametersUnitValues

Main

contactor

Contact Arrangement,Main Contacts/1 Form X(SPST NO DM)
Rated Operating VoltageVDC12-1000
OvercurrentA20A 180S/30A 120S
Break Current at 320VDCA100,1 Cycle
Contact Resistance, Typ.(@10A)mOhm≤5
Dielectric Withstanding VoltageVAC2500,(5mA,60s)
Insulation Resistor @1000VDCMOhm≥100
LifeLoad life 10A/450VCycle7*104
Load life 10A/750V2*103
Load life 10A/1000V103
Mechanical LifeCycle2*106
Pick up/ReleaseClose(includes bounce),Typ.ms20
Release(includes arcing),Maxms5
EnvironmentShock,11ms,1/2 Sine,Peak,operatingG50
Vibration,Sine,80-2000Hz,PeakG20
Operating Ambient Temperature-40 ~ +85
Weight,Norminalg≤105

Product life estimated(Make/Break):


Product life estimated(Make/Break) curve under resistive load

Continuous current range

Use Precautions Of High Voltage DC Contactors


1. Contacts with the polarity of contactor,please operate according to the product identification promp.

2. Do not use fallen products.

3.Avoid installing products in strong magnetic fields(near transformers or magnets) or near objects with thermal radiation.

4. The product with energy saver has a reverse surge absorber circuit,so there is no need to use surge protector.
5.About 0.1 seconds after the product with energy saving board is connected to the power supply,the circuit starts to switch automatically.Do not turn off repeatedly at the same position,otherwise the contactor energy saving board may be damaged.
6. About the load life: This contactor is a high voltage DC switch,please do not exceed its switching ability and life parameters in the state of use,otherwise may lose the ability to cut off.Please replace if necessary.
7. If the coil and contacts of the contactor are continuously connected to the rated voltage(or current),the power supply is cut off and then switched on immediately,then the resistance of the coil will increase as the temperature of the coil increases,thus increasing the pick-up voltage of the product and possibly leading to excess of the rated suction voltage.In this case,the follwing measures should be taken: such as reducing the load current,limiting the duration of power on or using coil voltage higher than the rated pick-up voltage.
7. If the coil and contacts of the contactor are continuously connected to the rated voltage(or current),the power supply is cut off and then switched on immediately,then the resistance of the coil will increase as the temperature of the coil increases,thus increasing the pick-up voltage of the product and possibly leading to excess of the rated suction voltage.In this case,the follwing measures should be taken: such as reducing the load current,limiting the duration of power on or using coil voltage higher than the rated pick-up voltage.

China SEV SEVI Polarity Nonpolarity High Voltage DC Contactor 10A 20A 30A 50A 100A 150A 200A 250A 300A For Electric Vehicle supplier

SEV SEVI Polarity Nonpolarity High Voltage DC Contactor 10A 20A 30A 50A 100A 150A 200A 250A 300A For Electric Vehicle