Fast Acting Square Fuse NFS F5A 300V 8*4*7mm Black For Battery
Charges
Features Of The Square Fuse
* As we all know, fuses have the characteristics of small size.
Compared with other fuse devices, the size of square fuses is also
small among many fuses. In comparison, a lot of space has been
reduced.
* Secondly, except for the two leads, the surface of the square
fuse is made of plastic materials, so the surface is insulated,
which has the effect of flame retardant and insulation.
* Finally, another advantage of the square fuse is the ability to
segment. The breaking capacity of the open square fuse is
35A/250VC, which is slightly different from Littel's 392 miniature
fuse, but because it is a domestic fuse, the cost performance is
still very high. If it is not very demanding, choose our company
square fuse is also very advantageous.
Dimension Of The Square Fuse
Electronic Parameters Of The Square Fuse
P/N | Ampere | Voltage | Max Voltage | I2TMelting | Agency Approvals | ||||
cUR us | TUV | c UL us | CCC | KC | |||||
NFS0100A | 100mA | 300V | 1500 | 0.02 | ● | ○ | ● | ○ | ○ |
NFS0125A | 125mA | 300V | 760 | 0.10 | ● | ○ | ● | ○ | ○ |
NFS0160A | 160mA | 300V | 500 | 0.15 | ● | ○ | ● | ○ | ○ |
NFS0200A | 200mA | 300V | 260 | 0.21 | ● | ○ | ● | ○ | ○ |
NFS0250A | 250mA | 300V | 240 | 0.48 | ● | ○ | ● | ○ | ○ |
NFS0315A | 315mA | 300V | 220 | 0.78 | ● | ○ | ● | ○ | ○ |
NFS0400A | 400mA | 300V | 200 | 1.22 | ● | ○ | ● | ○ | ○ |
NFS0500A | 500mA | 300V | 190 | 2.11 | ● | ○ | ● | ○ | ○ |
NFS0630A | 630mA | 300V | 180 | 2.88 | ● | ○ | ● | ○ | ○ |
NFS0800A | 800mA | 300V | 160 | 3.92 | ● | ○ | ● | ○ | ○ |
NFS1100A | 1A | 300V | 140 | 5.77 | ● | ○ | ● | ○ | ○ |
NFS1125A | 1.25A | 300V | 130 | 8.34 | ● | ○ | ● | ○ | ○ |
NFS1160A | 1.6A | 300V | 120 | 13.60 | ● | ○ | ● | ○ | ○ |
NFS1200A | 2A | 300V | 100 | 26 | ● | ○ | ● | ○ | ○ |
NFS1250A | 2.5A | 300V | 100 | 42 | ● | ○ | ● | ○ | ○ |
NFS1300A | 3A | 300V | 100 | 45 | ● | ○ | ● | ○ | ○ |
NFS1315A | 3.15A | 300V | 100 | 90 | ● | ○ | ● | ○ | ○ |
NFS1350A | 3.5A | 300V | 100 | 100 | ● | ○ | ● | ○ | ○ |
NFS1400A | 4A | 300V | 100 | 120 | ● | ○ | ● | ○ | ○ |
NFS1500A | 5A | 300V | 100 | 170 | ● | ○ | ● | ○ | ○ |
NFS1630A | 6.3A | 300V | 100 | 290 | ● | ○ | ● | ○ | ○ |
NFS1800A | 8A | 300V | 100 | 320 | ○ | ○ | ● | ○ | ○ |
NFS2100A | 10A | 300V | 95 | 450 | ○ | ○ | ● | ○ | ○ |
NFS2120A | 12A | 300V | 95 | 460 | ○ | ○ | ● | ○ | ○ |
NFS2150A | 15A | 300V | 85 | 480 | ○ | ○ | ● | ○ | ○ |
NFS2160A | 16A | 300V | 85 | 515 | ○ | ○ | ● | ○ | ○ |
NFS2200A | 20A | 300V | 85 | 960 | ○ | ○ | ● | ○ | ○ |
Family Of The Square Fuse
Series | Size | Blow Type | Current Range | Voltage | Color | Approvals |
MTS | 8*4*8mm | Time-Lag | 50mA~20A | 250V | Black/Brown | UL/CUL/PSE/VDE/ |
MFS | 8*4*8mm | Quick Acting | 50mA~20A | 250V | Black/Brown | UL/CUL/TUV |
NTS | 8*4*8mm | Time Delay | 50mA~20A | 300V | Black/Brown | UL/CUL/TUV/CQC |
NFS | 8*4*8mm | Fast Blow | 50mA~20A | 300V | Black/Brown | UL/CUL/TUV |
TMS | 8*4*8mm | Slow Blow | 50mA~20A | 350V/400V/450V | Black/Brown | UL/CUL/TUV |
FMS | 8*4*8mm | Fast Acting | 50mA~20A | 350V/400V/450V | Black/Brown | UL/CUL/TUV |
96T | 12*6*9mm | Time Delay | 50mA~30A | 125V/250V/300V/350V/400V/500V | Black/Brown | |
96F | 12*6*9mm | Fast Acting | 50mA~30A | 125V/250V/300V/350V/400V/500V | Black/Brown | UL/CUL/TUV/ |
MTC | 8*4*5mm | Slow Blow | 50mA~10A | 250V/300V | Black/Brown | UL/CUL/CCC |
MFC | 8*4*5mm | Fast Acting | 50mA~10A | 250V/300V | Black/Brown | UL/CUL |
Advantages and disadvantages of fuses
1. Disadvantages of fuse:
In the past, electronic equipment and instruments used traditional
fuses for overcurrent protection, but they could only protect once.
If they were blown, they had to be replaced. In addition, abnormal
fuses would also be blown, such as the moment of power-on,
unplugging and inserting devices, poor contact, etc. Using the fuse
for too long will cause the fuse to blow. When the fuse is
replaced, it should be replaced with a fuse of the same
specification. However, in the industrial field, it often happens
that the fuse is replaced with whatever fuse exists, resulting in
wrong replacement. Accidents in which components burn out and cause
failures to expand frequently occur.
2. Advantages of self-recovery fuses:
The zero-power resistance of the resettable fuse at room
temperature can be made very small, and the high-current products
are only a few milliohms, the power consumption on the road is
small, can be ignored, and the volume is relatively small.
Self-recovery fuses can be connected in series in vulnerable
circuits for overcurrent protection and thermal fuses, with fast
resistance mutation speed, in the order of several ms, small heat
capacity, short recovery time, impact resistance, and cyclic
protection up to 8,000 times . The resettable fuse can be used as
an over-temperature fuse, so it reflects the performance of the
thermal fuse and the function of the thermal fuse to a certain
extent in the circuit. To achieve the dual protection function of
over-current protection and over-temperature protection in the
circuit.