Industrial mechanical vapour recompression MVR
A heat pump uses energy to transfer heat from a lower temperature source to a higher temperature demand using additional energy. For industrial heat pumps, the heat source is process waste heat.
Mechanical vapour recompression (MVR) is an open heat pump system in which the pressure and temperature of the vapour, together with the corresponding saturation temperature, are increased by means of compression. Steam recompression is a specific variation of MVR. Low-pressure steam exhaust from industrial operations, such as evaporators or cookers, is usually vented to the atmosphere or condensed in a cooling tower, while other plant operations on the same site may require intermediate-pressure steam. Instead of expanding high pressure steam across a throttling valve to meet these needs, low-pressure waste steam can be mechanically compressed to a higher pressure so that it can be reused. Steam recompression relies upon a mechanical compressor to increase the temperature of the latent heat in steam to render it usable for process duties. The advantage lies in the fact that the required compression energy is very small compared to the amount of latent heat present in the recycled steam.
The energetic performance of steam recompression is expressed in the coefficient of performance (COP). The COP gives the ratio of the net recovered heat and the energy used by the compressor. In this case, the net heat is the steam production including the additional steam yield by water injection. Typical economical and energy-efficient applications have a minimum COP of 3.5. Some applications of MVR have a COP of 10 or even higher.
The key elements for a high COP are the following:
A low ratio of the absolute steam pressures. A guideline for the maximum ratio is 6, but in daily practice the ratio is about 3.
A minimum capacity. A guideline is a minimum of one tonne of steam per hour.Water injection after compression.
Name | Pillow plate type | Shell and tube heat exchanger | Detachable plate heat exchanger | Spiral plate heat exchanger |
Operating temperature range | <800℃ | <800℃ | <170℃ | <350℃ |
Maximum pressure | <60 bar | <200 bar | <32 bar | <25 bar |
Heat transfer coefficient to water[W/m2·℃] | 3500 | 2700 | 5600 | 2000 |
Application of air and water heat exchange | fit | fit | not fit | Partial fit |
Immersion in tank or water | fit | Partial fit | not fit | not fit |
Welding of tank and reactor | Applicable | not applicable | not applicable | not applicable |
Install into the existing reactor and other equipment | Flexible application | Partial applicable | not applicable | not applicable |
All welded construction | Applicable | Applicable | not applicable | not applicable |
Heavily contaminated liquids and other applications | Applicable | Applicable | Partial Applicable | Applicable |
Weight per unit area | low | high | low | high |
Falling film, condenser and evaporator | fit | fit | Partial fit | Partial fit |
Product Name | MVR Evaporator |
Application | Waste Water Treatment |
Condenser | Vertical |
Warranty | 12 months |
Features | Energy Saving/Low operation cost |
Customized Service | Yes |
Equipment Structure
Double-effect forced circulation evaporator is composed of heater,
separator, vapor-liquid separator, condenser, vacuum pump, forced
circulation pump, discharging pump, condensate pump, electrical
cabinet, operation platform and all the pipe fittings, valves,
instruments and etc.
Heater: Two sets of vertical type tubular heater connect in series.
The feed liquid is pumped into the first heater by forced
circulation pump, then enters into the second heater. The heated
liquid flow downwards in tubes, and flow into separator by
tangential direction, better performance of vapor-liquid
separation.
Separator: Vertical type, the secondary steam is discharged from
the top, pass through a vapor-liquid separator before entering into
condenser. The bottom of separator is connected with a forced
circulation pump.
Vapor-liquid separator: Is used to prevent tiny liquid drops
produced during evaporation from escaping with secondary steam,
reducing loss of feed liquid and prevent pollution to pipeline and
cooling water.
Condenser: Condensate the huge secondary steam produced during
evaporation into liquid by cooling water, making concentration
carrying on smoothly. Meanwhile, separate non-condensable vapor
from secondary steam and cooling water, make it easily pumped out
by vacuum pump to guarantee vacuum degree.
Application
Distillation
During distillation, liquid mixtures of substances with different
vapor pressures and boiling temperatures are separated. Examples
include distillation of alcohol, or the recovery and purification
of solvents.
Concentration
Evaporation produces a concentration of the substance being
processed. In applications such concentrated milk or fruit juice
production, evaporative systems are also used as a precursor to
dryers in the food industry.
Crystallization
During the crystallization process, substances are separated from
one another by using different solution equilibria. Applications
include salt extraction and fertilizer production.
Production Capability