Corrosion Gas Test Chamber Overview

This test chamber allow to determine the corrosive effect of the woring and storage envirnoment on electrotechnical components, it can be used for single gas and mixed gas test. the methods apply with IEC60068-2-42 .



Main Technical Parameters (Product Model:EQF2330)
Temperature testTemperature range:20℃~+45℃Remark:

1. Test in accordance with GB/T2423 and IEC60068
under empty chamber condition (except indicated).

2. The test data of the water-cooled
test chamber are under the conditions that the water
temperature is less than 28, the water pressure is between 0.3Mpa and 0.6Mpa, and the
water pressure difference between inlet and outlet is more than 0.2Mpa.
Temperature uniformity:≤2.0℃
Temperature deviation:≤±2.0℃
Temperature fluctuation:≤±0.5℃
Temperature rate:≥1℃/min
Temperature and humidity climatic testHumidity temperature control range:20℃~+50℃
Humidity range:50%RH~85%RH
Humidity uniformity:±5.0%RH
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH)
Humidity fluctuation:±5.0%RH
Gas concentration5ppb~30ppm
The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,Concentration uniformity deviation of 10%
The empty chamber operation request meets the IEC60068-2-60 standard
Gas concentration measurementBy calculating the volume ratio and then through the mass flowmeter measurement
On load capacity500W,The temperature can be stable, the chamber body is not deformed
NoiseWorking noise ≤70dB (measured at 1 meter away from the test chamber)
Wind speed≤1.7m/s
Gas flowmeterH2S,SO2,NO2,CI2
Standard(IEC60068-2-1:2007) Test A: Low temperature test method
(IEC60068-2-2:2007) Test B: High temperature test method
(IEC60068-2-78:2007) Test Cab: Constant humidity and heat test
(IEC60068-2-30:2005) Test Db: alternating humidity and heat test
IEC60068-2-60 Test Method KE: Man-made low concentration pollution gas corrosion test
China IEC60068-2-42 Cl2 Noxious Gas Test Chamber For Quality Control supplier