Add to Cart
3 Phase Copper Core AC Output Reactor For VFD
What is the AC input / output reactor:
The input and Output AC reactor is a current-limiting device mainly
used for the input / output side of the drive so as to protect the
exchange drive from the influence of the transient overpressure. It
can also reduce the surge and peak current .increase the real power
factor ,restrain the harmonic wave in power grid and improve the
function of the input current waveform, and extend the transmission
distance from VFD / Solar pump inverter to motor.
High performance foil winding structure .low direct current
resistance ,strong resistance to short circuit and good overload
ability in short time characterizes this input AC reactor .For
above class composite insulating materials are used to maintain
reliable performance of the product under harsh working conditions,
the design of the facility is characterized by low magnetic flux
density ,excellent linearity and strong overload capacity
,Moreover, the cooperation of the design and vacuum pressure
impregnation process reduces the noise of the reactor which also
possesses the advantages of low consumption ,high efficiency of low
temperature rise .the iron core employs the cold rolled oriented
silicon steel sheet.
Technical data:
1.Rated operating Voltage: 1/3phase 220V 3phase 380/440V 50/60HZ.
2.Rated operating current: 5A to 1600A
3.Operating environment temperature:40ºC
4.Dielectric strength: Core-wingding 3000VAC/50Hz/5mA/10S
No flashover breakdown(factory test)
5.Insulation Resistance>1000VDC, Insulation resistance value
>100MΩ.
6.Noise of the reactor is less than 65dB ( Tested at the point with
a horizontal distance of 1 meter away from the reactor).
7.Level of protection:IP00
8.Insulation class: Above F
9.Executive standard of
product:GB19212.1-2008,GB19212.21-2007.GB1094.6-2011.
Copper core 3phase 380V/440V output reactor Model No.:
3Phase 380V/440V output reactor Model No. | ||||
used for VFD/solar VFD(KW) | Output reactor Model No. | Reactor Dimension (L*W*H)mm | Installation size (A*B) | Weight (kg) |
0.75KW | SD-5A | 110*110*130 | 90*65 | 4 |
1.5KW | SD-5A | 110*110*130 | 90*65 | 4 |
2.2KW | SD-10A | 110*110*130 | 90*65 | 4 |
3.7KW | SD-15A | 110*110*130 | 90*65 | 4 |
5.5KW | SD-15A | 155*130*130 | 95*60 | 4 |
7.5KW | SD-20A | 155*130*130 | 95*80 | 4.5 |
11KW | SD-30A | 155*135*130 | 95*80 | 5 |
15KW | SD-40A | 155*135*130 | 95*80 | 6 |
18.5KW | SD-50A | 155*135*130 | 95*80 | 7 |
22KW | SD-60A | 195*130*165 | 120*70 | 7.5 |
30KW | SD-80A | 195*130*165 | 120*70 | 9 |
37KW | SD-110A | 195*130*165 | 120*70 | 9 |
45KW | SD-125A | 195*135*165 | 120*90 | 10 |
55KW | SD-150A | 250*170*230 | 180*85 | 16 |
75KW | SD-200A | 250*170*230 | 180*85 | 17 |
93KW | SD-250A | 250*170*230 | 180*85 | 23 |
110KW | SD-275A | 250*170*230 | 180*85 | 25 |