MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad

Brand Name:ZK/ZUN
Certification:ISO CE
Model Number:SU10M-D2-2R2G-B
Minimum Order Quantity:1 Unit
Delivery Time:3-7 working days
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Guanlida Building, NO. 269 of Qianjin Road, Xin'an street,Bao'an,Shenzhen,Guangdong,China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

ZK/ZUN Solar VFD 0.75kw 2.2kw 450VDC 220VAC LED Keypad MPPT Vfd Solar Pump Inverter


SU10M-D2-2R2G-B mini size 2.2kw solar pump inverter


Quick Details:


1.Adopt advanced MPPT technology to give full play to the power generation efficiency of the solar cell array;
2.Automatically adjust the motor speed and the water output of the water pump according to the change of sunlight intensity;
3.The inverter automatically sleeps when the water level of the reservoir is high, and restarts automatically when the water level is low, realizing automatic water level control;
4.It can prevent the water pump from dry pumping without water when the water source is dry;
5.When the light is weak (such as the sun sets), it will automatically sleep, and when the light becomes strong (such as sunrise), it will exit the sleep;


Features:

1.Energy saving and environmental protection
2.Plastic shell and sheet metal shell design



ItemSpecification
Power inputVoltage, frequencyDI: 70V DC to 400V DC or 110V±15% AC, 50/60Hz S
D2: 150V DC to 450V DC or 220V±15% AC, 50/60Hz;
D3: 350V DC to 750V DC or 380V±15% AC, 50/60Hz
Allowable fluctuationsvoltage unbalance rate:<3%; Frequency:±5%; aberration rate: as IEC61800-2 required
Power factor≥0.94(with DC reactor)
Mppt Efficiency≥99.6%
OutputOutput voltageOutput under rated condition: 3 phase, 0~input voltage, inaccuracy<5%
Output frequency rangeG type:0~600Hz
Output frequency accuracyMax frequency ±0.5%
Overload capacityG type: 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s
Motor control modeV/F without PG , VC without PG , VC with PG
Product basic functionsAcceleration/Deceleration curve2 modes: linear Acceleration/Deceleration and S curve Acceleration/Deceleration.
4 sets of ACC/DEC, time unit 0.01s selectable, longest time: 650.00s.
Rated output voltageRely on power supply voltage compensate function, while motor rated voltage is 100%, set it at the range of 50-100%(output can not over input voltage).
Voltage auto-adjustmentWhile power supply voltage fluctuates, it can auto-keep constant output voltage.
Auto energy-saving runningWhile under V/F control mode, according to load situation, auto-optimize output voltage to save energy.
Standard functionsPID control, speed track, power off restart, jump frequency, upper/lower frequency limit control, program operation, multi- speed, RS485, analog output, frequency impulse output.
Frequency setting channelsKeyboard digital setting, keyboard potentiometer ,Analog voltage/current terminal AI1,AI2, Communication given and multi-channel terminal selection, Main and auxiliary channel combination, expansion card, supporting different modes switch.
Feedback input channelVoltage/Current Terminal AI1, Voltage/Current Terminal AI12, Communication
given, pulse input X5.
Running command channelOperation panel given,external terminal given, communication given, expansion card given.
Input command signalStart, stop, FWD/REV, JOG, multi-step speed, reset, ACC/DEC time selection, frequency given channel selection, exterior fault alarm.
Protective functionOvervoltage, under-voltage, current limit, over-current, overload, electric thermal relay, overheat, overvoltage stall, data protection, rapid speed protection, input/output phase failure protection.
EnvironmentInstall placealtitude ≤ 1000m,above 1000m down the rated amount, each increase of 100m down the rated mount of 1%;no condensation, ice ,rain, snow, hail; solar radiation below 700W/㎡, air pressure 70-106 kPa.
Temperature, humidity-10 ~ + 50 ℃, derating above 40 ℃, maximum temperature 60 ℃ (no-load operation)5% to 95% RH (non-condensing)
VibrationWhen 9~200Hz, 5.9m/s2(0.6g)
Storage temperature-30 ~+60℃
Protection gradeIP20
Cooling methodForced air cooling

Model List:


MODELSRate current (A)Applicable for pumps

Input Voltage

Range DC (V)

Output voltage
VAC
General type D1:90V DC to 400V DC or 110V±15% AC Input, 50/60Hz, 3 Phase 0-110Vac ouptut
SU10M-D1-R75G-B7A0.75kw70-400V0-110V
SU10M-D1-1R5G-B10A1.5kw70-400V0-110V
General type: D2:150V DC to 450V DC or 220V±15% AC Input, 50/60Hz, 3 Phase 0-220Vac ouptut
SU10M-D2-R75G-B4A0.75kw150-450V0-220V
SU10M-D2-1R5G-B7A1.5kw150-450V0-220V
SU10M-D2-2R2G-B10A2.2kw150-450V0-220V
SU10M-D2-004G-B16A4.0kw150-450V0-220V
General type: D3:250V DC to 800V DC or 380V±15% AC input, 50/60Hz, 3 Phase 0-380V/440Vac ouptut
SU100-D3-R75G-B3A0.75kw250-800V0-380V/440V
SU100-D3-1R5G-B4A1.5kw250-800V0-380V/440V
SU100-D3-2R2G-B6A2.2kw250-800V0-380V/440V
SU100-D3-004G-B9.2A4.0kw250-800V0-380V/440V
SU100-D3-5R5G-B13A5.5kw250-800V0-380V/440V
SU100-D3-7R5G-B17A7.5kw250-800V0-380V/440V
SU100-D3-011G-B25A11kw250-800V0-380V/440V
SU100-D3-015G-B32A15kw250-800V0-380V/440V
SU100-D3-018G-B37A18.5kw250-800V0-380V/440V
SU100-D3-022G-B45A22kw250-800V0-380V/440V
SU100-D3-030G60A30kw250-800V0-380V/440V
SU100-D3-037G75A37kw350-800V0-380V/440V
SU100-D3-045G90A45kw350-800V0-380V/440V
SU100-D3-055G112A55kw350-800V0-380V/440V
SU100-D3-075G150A75kw350-800V0-380V/440V

Inverter modelDimensions(mm)Installation(mm)Mounting aperture
WHDD1W1H1
SU100-D1-R75G-B8919013514479180M4×2
SU100-D2-R75G-B
SU100-D2-1R5G-B
SU100-D3-R75G-B
SU100-D3-1R5G-B
SU100-D3-2R2G-B
SU100-D1-1R5G-B10623014815796219M4×3
SU100-D2-2R2G-B
SU100-D2-004G-B
SU100-D3-004G-B
SU100-D3-5R5G-B
SU100-D3-7R5G-B
SU100-D3-011G-B130275160169115260M5×3
SU100-D3-015G-B
SU100-D3-018G-B155335191200141.5320M5×4
SU100-D3-022G-B

---FAQ---

Q1 : What's the different between inverter and solar inverter?
Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accpet DC input, it more save power.


Q2: What should be noticed when installing inverter?
Put the product in a place where is well ventilate,cool, dry and water-proof. Do not stress or put foreign objects into the inverter. Remember to turn on the inverter before turn on the appliance.



Q3:What is the payment terms?
100% T/T in advance for sample order. 30% T/T in advance, banlance 70% T/T before delivery for bulk order.


Q4:What is your main market?
Our brands are well known in Europe, Africa, Middle East, Southeast Asia and South America.


Q5 : How about the delivery time?
3-5 days for sample order;15-25 days for bulk order.


Q6:What is the supply capacity of your factory?
The monthly output of inverters is over 6,000 units.
For regular orders, we can deliver to you in 5-24 days.


China MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad supplier

MPPT 0.75kw 2.2kw Solar VFD Pump Drive 450VDC 220VAC With LED Keypad

Inquiry Cart 0