Home /

HCG Urine Fertility Test Kit Cassette High Accuracy For Obstetrics

HCG Urine Fertility Test Kit Cassette High Accuracy For Obstetrics

Brand Name:WWHS
Certification:ISO 13485, CE
Model Number:β-HCG
Minimum Order Quantity:500
Delivery Time:7 Days
Place of Origin:CN
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: Rm 505, 1st Building, Shenzhen Biomedicine Innovation Industrial Park, No. 14th, Jinhui Road, East Jinxiu Road, Kengzi Street, Pingshan District, Shenzhen
Supplier`s last login times: within 28 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

【Product name】

β- Human Chorionic Gonadotropin(β-HCG)Rapid Quantitative Test(Fluorescence immunoassay)

【Package specification】

25 Tests/kit


【Components】

NameQuantityComponent
Test cards25It is composed of fluorescent pad (coated with fluorescent labeled β-HCG monoclonal mouse antibody), nitrocellulose membrane (coated with β-HCG monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
Sample diluent25(300μL/tube)Phosphate buffer
ID card1With specific stand curve file

The components in different batches of kits cannot be used interchangeably.

【Storage conditions and validity】

The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

The production date, batch number and expiration date are shown in the outer package of the product.

【Procedure】

  1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
  2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
  3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
  4. Place the test card on a clean horizontal table and mark it horizontally.
  5. Mix 20 µL of patient sample with 300µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
  6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 10 minutes after addition of samples, then dispose of used test appropriately.

【Performance】

1. Limits of detection

No more than 2mIU/mL.

2. Accuracy

The relative deviation from the target value is within ±15%.

3. Precision

The within and between assay coefficient of variations are within 15%.

4. Linear range

Within the linear range (2 ~ 100000mIU/mL), the linear correlation coefficient R≥0.990.

【Note】

1. This kit is only used for in vitro diagnosis.

2. The test card and sample diluent are disposable and cannot be reused.

3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.



Assay list     
Cardiac     
cat#.Product itemSpecimenReaction TimeMeasure RangeClinical RangeItended Use
1cTnIWB/Serum/Plasma12min.0.1-40ng/ml<0.3ng/mlseveral heart diseases including myocardial infarction and heart failure.
2MyoWB/Serum/Plasma12min.5-400ng/ml<58ng/mlacute myocardial infarction (AMI) in early stage.
3CK-MBWB/Serum/Plasma12min.1-200ng/ml<5ng/mlacute myocardial infarction (AMI) in early stage.
4NT-proBNPWB/Serum/Plasma10min.20-35000pg/mlUnder 75:0~347pg/mL,
Over 75:0~449pg/mL
heart failure .
5D-DimerWB/Plasma10min.40-10000ng/ml<500ng/mldisseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
6cTnI+Myo+CKMBWB/Serum/Plasma12min.same with single itemsame with single itemTriple marker of myocardial infarction.
7ST2WB/Serum/Plasma10min.10-400ng/ml<35ng/mlheart failure .
8Lp-PLA2WB/Serum/Plasma10min.10-900ng/ml<175ng/mlRisk evaluation of ACS and atherosclerotic ischemic stroke patients.
9S100-βWB/Serum/Plasma10min.0.05-10ng/ml<0.2ng/mlCerebral infarction, cerebral injury.
Inflammation     
10CRP / hs-CRPWB/Serum/Plasma3min.0.5-200mg/LCRP<10mg/L,hs-CRP<1mg/Lnonspecficity inflammatory marker.
11SAASerum5min.1-200mg/L<10mg/Linflammation&infection.
12PCTWB/Serum/Plasma10min.0.2-100ng/ml<0.5ng/mlSepsis
13CRP+SAAWB/Serum/Plasma5min.same with single itemsame with single iteminflammation&infection.
14IL-6WB/Serum/Plasma10min.5-4000pg/ml10pg/mldiabetes,rheumatoid arthritis,etc
Thyroid Hormone     
15TSHSerum/Plasma15min.0.3-100mU/L0.35-5mU/Lhyperthyroidism and hypothyroidism
16TT3Serum/Plasma15min.0.5-10nmol/L1.3-3.1nmol/Lthyroid dysfunction
17TT4Serum/Plasma15min.5-300nmol/L66-181nmol/Lthyroid dysfunction
18FT3Serum/Plasma15min.1-100pmol/L4-10pmol/Lthyroid dysfunction
19FT4Serum/Plasma15min.5-300pmol/L19-39pmol/Lthyroid dysfunction
Tumor Marker     
20AFPSerum/Plasma15min.2.5-200ng/ml<20ng/mlpregnancy cancer
21CEASerum/Plasma15min.1-200ng/ml<5ng/mlcolon cancer, colorectal cancer,etc.
22NSESerum/Plasma15min.1-400ng/ml<16ng/mlnon-small cell lung cancer
23FOBfecal specimens10min.50-1000ng/ml<100ng/mlAbnormal recessive gastrointestinal bleeding
24PG IISerum/Plasma15min.1-100ug/LPGI/PGII>3.0gastric abnormalities
25PG ISerum/Plasma15min.2.5-200ug/L>70ng/mlgastric abnormalities
26TPSASerum/Plasma15min.0.5-40ng/ml<4ng/mlprostate cancer
27FPSASerum/Plasma15min.0.1-10ng/ml<1ng/mlprostate cancer
28CA12-5Serum/Plasma15min.20-500U/ml<35U/mlovarian cancer
29CA15-3Serum/Plasma15min.10-400U/ml< 25 U/mLbreast cancer
30HE4Serum/Plasma15min.50-2000pmol/L<140 pmol/Lovarian cancer
31CA19-9Serum/Plasma15min.10-400U/ml< 27 U/mLpancreatic cancer
32β-HCGSerum/Plasma15min.5-400mIU/ml<10 mIU/mLEarly pregrancy, ectopic HCG cancer,incomplete abortion
33CK19(Cyfra21-1)Serum/Plasma15min.0.5-50ng/ml<2.5ng/mlnon-small cell lung cancer
Fertility     
34HCG / β-HCGSerum/Plasma10min.5-20000mIU/ml<5 mIU/mLearly pregrancy.
35AMHSerum/Plasma10min.0.1-16ng/mlMale: 20-60 years old, 0.92-13.89 ng/mL
Female: 20-29 years old, 0.88-10.35 ng/mL
30-39 years old, 0.31-7.86 ng/mL 40 -50 years old, <5. 07 ng/mL
ovarian reserve level
Gastrointestinal      
36FOBfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
37TRFfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
38FOB+TRFfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
Infection      
39C.PneumoniaWB/Serum/Plasma15min.qualitativequalitativeCP infection
40M.PneumoniaWB/Serum/Plasma15min.qualitativequalitativeMP infection
41Covid-19 Antigennasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
42Covid-19 Ab IgG/IgMWB/Serum/Plasma15min.qualitativequalitativerespiratory tract
43FluAnasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
44FluBnasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
Renal Injury      
45CysCWB/Serum/Plasma5min.0.4-9mg/L0.5-1.1mg/Lrenal function
46NGALUrine10min.10-1500ng/mL<132ng/mLacute kidney injury.
Other      
47FERRSerum5min.10-500ng/mlMale:24ng/mL~335ng/mL,
Female:11ng/mL~307ng/mL
iron metabolism related diseases, such as hemochromatosis and iron deficiency anemia
48HbA1cWB10min.4%-14%4%-6%diabetes
49VDSerum/Plasma15min.8-70ng/mL19-57ng/mLfetation

Advantage:


1. Advanced Quality: We have strict quality control system and enjoy good reputation in the market.

2. Sincerly Service: We treat clients as friend and aims at building long term business relatiionship.


FAQ:


1. What is the MOQ?


Generally if you choose the different products, our minimum order qty. also will be different. One sample available.


2. What about the delivery time?


The goods need 7-21 work days to be made upon deposit.


3. Does your product have any warranty?


Yes, we offer 6 months limited warranty for our products.


Damage due to misuse, ill treatment and unauthorized modifications and repairs are not covered by our warranty.


4. What's your payment method?


We usually accept the payment methods include PayPal, TT, and Western Union.


50% deposit in advance and balance before shipping. Buyer can choose which payment ways that you accept.


PayPal is most useful and safe, please don’t refuse PayPal fee when you choose PayPal.


5. What's your shipping method?


We provide comprehensive shipping methods.


For small quantity orders we ship by DHL Air-Express, or EMS/TNT/UPS/FEDEX Express service, it is safe and fast.


For large quantity orders we ship by Air transportation or sea transportation, we can also ship order to buyer’s cargo agent in China.


China HCG Urine Fertility Test Kit Cassette High Accuracy For Obstetrics supplier

HCG Urine Fertility Test Kit Cassette High Accuracy For Obstetrics

Inquiry Cart 0