Add to Cart
High End Standard Variable Frequency Inverters VFD580 Series
Veikong High End Standard VFD580 Series New Model With Brand New
Outlook
1. Veikong high end VFD580 series product features
1) Compatible for both IM and PMSM, support speed, torque and position serve.
2) Excellent SVC algorithm, high precision low frequency torque.
3) Support European standard STO function.
4) Plug-in terminals, more user friendly.
5) Standard motor temperature sensor interface, support PT100, PT1000, KTY84.
2. VFD580 technical specification
Item | Specification |
Operation mode | Speed control, torque control (SVC and VC), position servo |
Frequency control range | 0.00~600.00Hz(standard) 0.0~1000.0Hz(High frequency) |
Input frequency resolution | Digital input: 0.01Hz or 0.01% Analog input: 0.025% of maximum frequency |
Torque control accuracy | SVC:5Hz within 8%,5Hz above 5% VC:3.0% |
Position control | The position command supports internal position, pulse position input, CANopen position command, EtherCAT position command (MT586). Support position fully closed loop mod |
Special function | Built-in delay unit, comparison unit and logic unit, etc., two groups of motor parameter switching, software switching output phase sequence, spindle orientation, online identification of motor parameters |
3. VFD580 series product pic and inner board
3. New product introduction
The VFD580 is a high-end variable frequency drive. The product adopts the leading design concept, mainly for occasions with high requirements for the comprehensive performance of the product. Compared to traditional frequency converters, VFD580 has the following features:
1. Drive three-phase AC asynchronous motor and three-phase AC permanent magnet synchronous motor, and supports speed, torque and position servo control.
2. Excellent SVC algorithms for asynchronous and synchronous motors, enable high-precision motor speed and torque control even without encoder feedback.
3. 15kW and above are equipped with a built-in DC reactor as standard.
4. The built-in brake unit (45kW~90kW optional) is equipped as standard within 37kW, and the brake circuit short circuit detection function is equipped.
5. All weak current circuit terminals adopt plug-in terminals, humanized identification, convenient wiring and maintenance.
6. An incremental encoder interface with Z input is standard, eliminating the need to purchase a separate PG card in common closed-loop speed applications.
7. Standard motor temperature sensor interface, support PT100, PT1000, KTY84, no need for optional temperature detection card.
8. The whole series is equipped with buffer relay (contactor) abnormal protection circuit, which can effectively prevent accidents such as fire caused by component damage.