220V 5.5KW 7.5KW Solar Pump Inverter VFD Single Phase Input Output

Brand Name:VEIKONG
Certification:CE
Model Number:VFD500M-PV
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:Western Union, T/T, L/C, D/A, D/P, PayPal
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Product Details Company Profile
Product Details

220V 5.5KW 7.5KW Solar Pump Inverter VFD Single Phase Input Output


220V 5.5KW 7.5KW Solar Pump Inverter Single Phase Input Single Phase Output


VFD Single Phase Input Feature:


  1. Support Hybrid solar power and ac power at same time
  2. Support optional LCD keypad, you will know all parameters meaning , no need user manual
  3. Support optional GPRS module to remote control and monitor solar pumping situation
  4. Support optional output reactor to protect the motor
  5. Support water full, dry running, wake and sleep protection functions.


Eletrical Specification


220V380V
Max input DC voltage450V810V
DC voltage range150~450VDC250~810VDC
Recommended input mppt voltage305V530V
MPPT efficiency>99%
Rated output voltage1/3-phase 220VAC3-phase 380-480VAC
Output frequency range50/60Hz
Max efficiency of the machine99%
Ambient temperature range-10 °C~50 °C, derating if the temperature is above 40 °C
Cooling methodAir cooling
Protection degreeIP20/IP21
AltitudeBelow 1000m; above 1% for every additional 100m.
StandardCE/ROHS

Product Model


Drive modelMax DC input current (A)Rated output current (A)Applicable water pump (kW)
VFD500M-40T00075-PV4.22.50.75
VFD500M-40T00150-PV6.13.71.5
VFD500M-40T00220-PV7.152.2
VFD500M-40T00400-PV16.59.44
VFD500M-40T00550-PV23.9135.5
VFD500M-40T00750-PV30.6177.5
220V single phase or three phase level
VFD500M-20T00075-PV6.74.50.75
VFD500M-20T00150-PV9.971.5
VFD500M-20T00220-PV14.1112.2
VFD500M-20T00400-PV22.6174

Product Details




FAQ:


1. How to use a float in the water tank to stop the pump if the tank is full?


Use float switch to short DI 1 and com.


2.1 How to set minimum frequency 25hz and maximum 50HZ?


Set P47.05=25HZ and 47.06 to some time and 47.07 to some time


3. 1 If pump is 60HZ frequency ,how to set max frequency?


Notice:If your motor rated frequency is 60HZ you should set P01.06=P01.08=P11.05=60HZ.


China 220V 5.5KW 7.5KW Solar Pump Inverter VFD Single Phase Input Output supplier

220V 5.5KW 7.5KW Solar Pump Inverter VFD Single Phase Input Output

Inquiry Cart 0