1. Veikong solar pump inverter trial run description
Trial run(How to start solar pump inverter)
Make sure all cables connections of solar panel and pump motor
correct and noneed to set any parameter, if you want to set
parameter, you can do as follows.
Step 1: (Keypad control):Set motor parameter P11.02- P11.06 as per
motor pump nameplate lf dry run protection is required, measure the
unload protection current(see details inuser manual chapter for dry
run function) lf dry run protection not required then miss this
stepand go to step 2.
Step 2: Set other related special solar pump parameters for
optimization if needed.
Step 3: After trial run finishing, if motor pump still not output
water when inverter is runningmore than 40 Hz. Please disconnect
the power supply and replace any two-phase wiring ofthe motor
2. VFD500-PV technical specification data
220V | 380V | |
Max input DC voltage(VOC) | 450V | 800V |
DC voltage range | 160 to 450VDC | 300 to 800VDC |
Recommended DC input voltage range(Vmpp) | 250 to 400V | 450 to 600V |
Recommended input operation voltage | 305V(Vmpp) | 530V(Vmpp) |
MPPT efficiency | >99% | |
Rated output voltage | 1 or 3 phase 220VAC | 3 phase 380 to 480VAC |
Output frequency range | 50 or 60HZ(maximum 600hz) | |
Max efficiency of the machine | 99% | |
Ambient temperature range | -10 to 50 Celsius, derating if the temperature is above 40 celsius | |
Cooling method | Air cooling | |
Protection defree | IP20 or IP21 | |
Altitude | Below 1000m, above 1% for every additional 100m | |
Standard | CE or ROHS |
3. VEIKONG Manufacturing Enviroment
4. VFD500-PV series product brochure and user manual download
VEIKONG VFD500-PV Hybrid Solar pumping inverter us...
VEIKONG solar pump inverter brochure.pdf
5. Technical Questions and solutions
1) How to achieve Automatic start after stop? If it is controlled
by keyboard,so there is no need to set any parameter(P47.03 waiting
time)If you want to control by external switch,First set P00.06=1
and use a wire or switch to connect com and DI1,When the switch is
closed, the drive run, when the switch is open, the drive stop
2) How to use a float in the water tank to stop the pump if the
tank is full? If your float signal is digital signal Use float
switch to short DI 3 and com ,see diagram 1.3 15
3) Use level probe in the well for protection against dry running
1 st solution: See self learning of dry run(For LED display)
2 nd solution: do it manually Set P24.13=30%-60%(as per real empty
load current percentage based on rated current) and P24.14 P24.16
and P23.21
3 rd solution: If your sensor is digital switch ,just short D4 and
com
4 th solution:If your float signal is Analog signal, Connect Ai2
and 10V and GND and set P41.00=23 and P41.03-P41.06
6. Veikong product warranty
Veikong provide you 18 months warranty, if there is anything broken
down during this period, we will be responsible for that.
Besides, any parts broken down, we will send out free parts via
express or with next order which is up to our clients.
Veikong is and will be trying our best to provide you better
service and better quality products~