Home /Connectors & Terminals /

MPPT 99% Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW

MPPT 99% Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW

Brand Name:VEIKONG
Certification:CE
Model Number:VFD500-PV
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

MPPT 99% Solar water pump inverter single phase three phase 0.75KW-710KW


VEIKONG is professional manufacturer of solar pump inverter, variable frequency dirve, soft starter.


Electrical Specifications and Power degree


220V380V
Max input DC voltage450V810V
DC voltage range150~450VDC300~810VDC
Normal working DC voltage260V-400V400V-650V
Recommended input mppt voltage330V550V
MPPT efficiency>99%
Rated output voltage1/3-phase 220VAC3-phase 380-480VAC
Output frequency range50/60Hz
Max efficiency of the machine99%
Power range220v 0.75kw to 75kw, 380v 1.5kw-160kw
Cooling methodAir cooling
Protection degreeIP20/IP65
AltitudeBelow 1000m; above 1% for every additional 100m.
StandardCE/ROHS

Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,

And solar pump inverter power should be higher level than solar pump.

When solar pump distance to inverter higher than 100m,

It should be equipped with Output reactor or higher level power inverter.

For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend

530V for 380V pump and 305V for 220V pump.


VEIKONG VFD500-PV solar pump inverter Features:


● Worldwide applicable voltage levels and power ranges

Supports 220V single/three-phase, 380V three-phase water pumps, power ranges from 0.75kW to 710kW.


● Fully intelligent

  • Simply connect the photovoltaic panels to the inverter, no need to set any parameters and the water pump will start automatically when powered on.

  • Automatic adjustment of the water output in response to changes in sunlight.

  • Automatic dormancy in weak light (e.g. after sunset), withdrawal from dormancy in strong light (e.g. at sunrise).

  • Automatic dormancy when the water level is high and automatic restart when the water level is low, enabling automatic water level control.

  • Specially designed for water pump users, easy to operate and adaptable to various applications.


● Multiple protection

Protection features such as PV over-voltage protection, PV reverse polarity alarm, automatic over-temperature derating, etc. can effectively extend the product life


● Advanced MPPT technology

Ensures solar tracking efficiency up to 99%


● AC/DC switching solution

The whole series of products can automatically switch between PV DC input and grid AC input, which can meet 24-hour water consumption and no manual operation is required.


Mode Range


Drive modelMax DC input current (A)Rated output current (A)Applicable water pump (kW)
VFD500M-40T00150-PV6.13.71.5
VFD500M-40T00220-PV7.152.2
VFD500M-40T00400-PV16.59.44
VFD500M-40T00550-PV23.9135.5
VFD500M-40T00750-PV30.6177.5
VFD500-40T00150-PV6.13.71.5
VFD500-40T00220-PV7.152.2
VFD500-40T00400-PV16.59.44
VFD500-40T00550-PV23.9135.5
VFD500-40T00750-PV30.6177.5
VFD50040T01100-PV39.22511
VFD500-40T01500-PV49.03215
VFD500-40T01850-PV573718.5
VFD500-40T02200-PV694522
VFD500-40T03000-PV916030
VFD500-40T03700-PV1147537
VFD500-40T04500-PV1469045
VFD500-40T05500-PV19011255
VFD500-40T07500-PV23715275
VFD500-40T09000-PV27317690
VFD500-40T11000-PV319210110
VFD500-40T13200-PV389253132
220V single phase or three phase level
VFD500-20T00075-PV6.74.50.75
VFD500-20T00150-PV9.971.5
VFD500-20T00220-PV14.110.62.2
VFD500-20T00400-PV22.6174
VFD500M-20T00150-PV9.971.5
VFD500M-20T00220-PV14.110.62.2

Product Application


Techincal Parameters:


1. Wake up and sleep function parameters:


P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
P47.06Light detection timeSee P47.05 for explanation.60s
P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s

2. Dry runing protection function parameters:


P24.12Dry run/Unload protection option

0: No offload detection is performed;

1: Enable dry run detection

1
P24.13Dry run/Unload detection level

0.0 to 200.0%

The percentage of motor rated current.

0.0%
P24.14Dry run Unload detection time0.000s~60.000s30.000s
P24.15Unload detection offset frequency

0.00Hz~Fmax

Detection frequency=Fmax-P24.15


5.00Hz
P24.16Reset time of dry run protection0.0~6000.0240.0s
P23.21Dry run detection mode

0000:Coast stop

1000:Fast stop

3000:Continue to run

0000

3. Water full protection function parameters:


P47.18Full water level detection channel

0:ineffective

1:AI1

2:AI2

3:AI3

4:AI4

Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

0
P47.19Full water level detection value

0.0~100.0%


0.0%
P47.20Full water level detection time

0.0~3000.0s

When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.


10.0s
P47.21Full water recovery time

0.0~3000.0s

When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

10.0s

China MPPT 99% Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW supplier

MPPT 99% Solar Water Pump Inverter Single Phase Three Phase 0.75KW - 710KW

Inquiry Cart 0