VEIKONG 2% Voltage Drop AC Output Reactor For Vfd 45kw 55kw Ac Drive Inverter

Brand Name:VEIKONG
Certification:CE
Model Number:VKS
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:Western Union, T/T, L/C, D/A, D/P, PayPal
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Product Details Company Profile
Product Details

2% Voltage drop AC output Reactor choke for 3phase ac drive inverter


Description of Load Reactor:

VKS-OCL series Load Reactors are placed in series with electrical equipment to introduce a specific controlled impedance to the AC circuit. This series are applied at AC drive output side to suppress inrush voltage, reducing inrush and peak current, improving real power factor, restraining grid harmonics and improving the output current waveform. Line Reactor also known as Output Reactor.


1. High efficiency:
The battery with the same capacitance, higher efficiency, longer use time. Reliable inverter use the most advanced technology to raise the efficiency to 90%, save more energy, more environmental protection.

2. Protection systems:
Thermal protection, Overload protection, Over Voltage protection, Under Voltage protection, Low Voltage protection alarm. Inverter comes with an LED light to indicate the problem.


Technical Data of AC reactor.


1, Rated Operating Power:φ3/380V/50Hz or 660V/50Hz;

2, Rated operating current:3Ato 2000A@40℃

3, Reactive Strength:Core-Winding 3000VAC/50Hz/10mA/10S Free

of arcing breakage (ftested in factory)

4, Insulation Resistance:1000VDC,insulation resistance≥100MΩ

5, Reactor’S noise is less than 65dB(to be measured at the point 1

meter away from the reactor horizontally)

6, Protection class:IP00

7, Insulation class:Above F

8, Standard: IEC289:1987 Reactor

GB10229-88 Reactor(equivalent to IEC289:


Benefits:

Obvious interference to other devices from power supply (such as interference, overvoltage) Interphase voltage is unbalanced >1.8% of rated voltage Low impedance line (Power transformer is about 10 times of rated data of inverter) Large quantity of inverter mounted on the same power line but have to minimize line current power factor calibrating capacitor or power factor correcting unit applied..


Product Parameters


Voltage Range

DC500V-1000V

Dielectric Strength

Core-Winding, AC 3000V/50Hz/5mA, free of damage in 60s

Insulation Resistance

Core-Winding, DC 1000V, Resistance > 100M ohm

Reactor's noise

less than 65dB(to be measured at the point 1 meter away from the reactor horizontally)

Standard

GB 19212.1-2008 GB/T 1094.6-2011


Product Size


China VEIKONG 2% Voltage Drop AC Output Reactor For Vfd 45kw 55kw Ac Drive Inverter supplier

VEIKONG 2% Voltage Drop AC Output Reactor For Vfd 45kw 55kw Ac Drive Inverter

Inquiry Cart 0