Intuitive Programming 22kw 30kw 37kw 45kw Motor Soft Starter Bulit In Bypass

Brand Name:VEIKONG
Certification:CE
Model Number:VKS6000
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:Western Union, T/T, L/C, D/A, D/P, PayPal
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Product Details Company Profile
Product Details

22kw 30kw 37kw 45kw 55kw 75kw 90kw soft starter bulit in Bypass


Product feature

VKS-8000 is a highly intelligent, very reliable and easy to use soft starter. The newly designed functions of VKS-8000 are used for quick setting or more personalized control.

It's a perfect solution. Its performance includes:

Large LCD screen that can display feedback information in Chinese and English languages, other languages can be customized.

Remotely installable operation panel.

Intuitive programming.

Advanced start and stop control functions.

A series of motor protection functions.

Extensive performance monitoring and event logging.

Run the simulation

In the absence of three-phase power or load motor, the soft start control loop can be tested, which is convenient for users to test.


Product Application


Protocol

The factory is Modbus protocol, and PROFIBUS communication protocol can be customized, which can facilitate communication with German Siemens PLC and touch screen.


More control

VKS-8000 soft starter adopts a new generation of soft start technology, and adaptive control realizes the control of the motor acceleration curve and deceleration curve to an unprecedented level.

The soft starter reads the data of the motor in the process of starting and stopping, and then adjusts to achieve the best effect. Just select the curve most suitable for your load type, and the soft starter will automatically ensure that the load is accelerated in the most stable way possible.





Technical Specification

ItemDescription
Input Power SupplyInput VoltageThree-phase 380V/480V/660 AC
Frequency50/60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.



Control Mode

(1) Operation panel control.

(2) Operation panel + external control.

(3) External control.

(4) External control + COM control.

(5) Operation panel + external + COM control.

(6) Operation panel + COM control.

(7) COM control.

(8) No start or stop operation.


Start Mode

(1) Current-limiting to start.

(2) Voltage ramp to start.

(3) Torque control + current-limiting to start.

(4) Torque control + voltage ramp to start.

(5) Current ramp to start.

(6) Voltage current-limiting double closed-loop start.

Stop Mode

(1) Soft stop.

(2) Free stop.






Protective Function

(1) Open loop protection for external instantaneous stop terminals.

(2) Over-heat protection for soft starter.

(3) Protection for too long starting time.

(4) Input open phase protection.

(5) Output open phase protection.

(6) Unbalanced three-phase protection.

(7) starting over current protection.

(8) Running overload protection.

(9) Under voltage protection for power voltage.

(10) Overvoltage protection for power voltage.

(11) Protection for fault parameter setting.

(12) Load short circuit protection.

(13) Auto restart or incorrect wiring protection.

(14) Incorrect wiring protection of external control stop terminals.


Ambient

Place to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
Altitude

Below 1000M. It have to rise the rate power when the altitude is more than 1000M.

Temperature-20 +45 C
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureProtection ClassIP20
Cooling PatternFans cooling.


Product Application



Protection response


When the protection condition is detected, the soft starter writes the protection condition into the program, and it may trip or issue a warning. Soft starter response depends on Parameter setting C. Protection IcvcL

The user cannot adjust some of these protection responses. These trips arc usually caused by external events (such as phase loss), and may also be caused by internal faults in the soft starter.

Into. These trips have no relevant parameters and cannot be set as warning or ignored.

If the soft starter trips, you need to identify and clear the conditions that triggered the trip, reset the soft starter, and then restart. To reset the starter, you need

Press the RESET button on the operation panel, or activate "Reset Remote Input11.

China Intuitive Programming 22kw 30kw 37kw 45kw Motor Soft Starter Bulit In Bypass supplier

Intuitive Programming 22kw 30kw 37kw 45kw Motor Soft Starter Bulit In Bypass