High Capacity 256k TI DSP for Faster Response and Higher Accuracy in VFD530 for PMSM Inverter

Brand Name:VEIKONG
Certification:CE
Model Number:VFD530
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Product Details Company Profile
Product Details
380V 7.5kw 10hp VFD Converter for PMSM Motor Synchronous Motor
VEIKONG hot selling VFD
VFD500M is high performance vector control mini vfd
VFD500 is high performacne general vfd
VFD550 is high perfromance special vfd with positional control.
VFD530 is high performance special vfd with lifting function, support 2 PID, support Synchronous and asynchronous motors
VFD500-PV is solar pump inverter.
VFD510 is IP65 inverter
VFD530 features:
Our VFD530 is updated from VFD500(high performance general inverter)
Support Asynchornous & Synchronous motor.
Out frequency up to 3000HZ.
Up to 200% starting torque at 0HZ.
High capacity 256k TI DSP with faster response and higher accuracy.
Special brake logic mechanism for crane and hoist
Magnetic flux brake gain
Support 2 PID loop for HVAC
VFD530 control mode:
ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating modeSpeed control,Torque control(SVC and VC)
Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

frequency range

0.00~2000.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

Carrier frequency1kHz~12kHz(Varies depending on the type)
Startup methodDirect start (can be superimposed DC brake); speed tracking start
Stop methodDeceleration stop (can be superimposed DC braking); free to stop
Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN

Product series instruction:


Model

Power capacity

(KVA)

Input current

(A)

Output current(A)

Adaptable Motor

(KW)

SIZEBrake Unit
Heavy loadLight load
Three phase: 380-480V,50/60Hz
VFD530-R75GT4B1.53.42.54.20.75SIZE AInternal
VFD530-1R5GT4B354.25.61.5
VFD530-2R2GT4B45.85.69.42.2
VFD530-4R0G/5R5PT4B5.910.59.413.03.7
VFD530-5R5G/7R5PT4B8.914.613.017.05.5SIZE B
VFD530-7R5G/011PT4B1120.517.023.07.5
VFD530-011G/015PT4B1726.025.031.011SIZE CInternal
VFD530-015G/018PT4B2135.032.037.015
VFD530-018G/022PT4B2438.537.045.018.5SIZE D
VFD530-022G/030PT4B3046.545.057.022
VFD530-030G/037PT44062.060.075.030SIZE Eoption
VFD530-037G/045PT45076.075.087.037
VFD530-045G/055PT46092.090.0110.045SIZE F
VFD530-055G/075PT475113.0110.0135.055
VFD530-075G/090PT4104157.0152.0165.075SIZE G
VFD530-090G/110PT4112170.0176.0210.090External
VFD530-110G/132PT4145220.0210.0253.0110SIZE H
VFD530-132G/160PT4170258.0253.0304.0132SIZE I
VFD530-160G/185PT4210320.0304.0360.0160
VFD530-185G/200PT4245372.0360.0380.0185SIZE J
VFD530-200G/220PT4250380.0380.0426.0200
VFD530-220G/250PT4280425.0426.0465.0220SIZE K
VFD530-250G/280PT4315479.0465.0520.0250
VFD530-280G/315PT4350532.0520.0585.0280SIZE L
VFD530-315G/355PT4385585.0585.0650.0315
VFD530-355G/400PT4420638.0650.0725.0355SIZE M
VFD530-400G/450PT4470714.0725.0820.0400
VFD530-450G/500PT4530800.0820.0/450SIZE N
VFD530-500G/560PT4580880.0900.0/500
VFD530-560G/630PT4630950.0980.0/560SIZE O
VFD530-630GT471010801120./630SIZE O
VFD530-710GT479012001260/710SIZE O
Single phase :220V ,50/60HZ
VFD530-R40GS21.36.03.25.60.4SIZE AInbuilt
VFD530-R75GS22.411.05.68.00.75SIZE A
VFD530-1R5GS23.515.08.010.61.5SIZE A
VFD530-2R2GS25.525.010.614.02.2SIZE A
VFD530-4R0GS27.735.017.023.04.0SIZE B
VFD530-5R5GS28.953.025.031.05.5SIZE C
VFD530-7R5GS21167.032.037.07.5SIZE C

VEIKONG VFD application:


VEIKONG VFD replace famous brands


Synchronous motor control:
17 group synchronous motor control
P17.00Initial position identification mode

0:Pulse testing

1: High frequency injection

1
P17.01Initial position identification current50%~180%100%
P17.03Low speed zone definition0.1% ~ 60.0%10.0%
P17.07High frequency injection amplitude

5% ~ 50.0%

For the amplitude of high-frequency signal injection, the larger the set value, the higher the accuracy of position identification, but the greater the noise of the motor. The set value should be as small as possible when the accuracy meets the requirements.

20.0%
P17.11Operation mode in low speed in SVC

0: normal way

1: High frequency injection operation

0
P17.12No load current in low speed in SVC0.0% ~ 100.0%20%
P17.13No load current in high speed in SVC0.0% ~ 50.0%2.0%
P17.18MTPA control

0:disable

1:enable

MTPA is the maximum torque current ratio control. Enabling MTPA can reduce the motor current when SVC and VC are running under load.

0
P17.19MTPA control adjust timeThe smaller the set value, the faster the MTPA will act, it will cause current oscillation if set value too small0.500

VFD530 parameter distribution list


ClassificationParameter groupPage
Common parameters00:Basic functionPage 39
01:Frequency source selectionPage 41
02:Start and stopPage 47
03:Ramp and S curvePage 51
04: Analog and pulse inputPage 53
05:Analog and pulse outputPage 57
06:Multi-function Digital input (DI)Page 58
07: Multi-function Digital output(DO)Page 61
08:Digital Output settingPage 64
Motor control10:Encoder typePage 67
11:Motor1 parmeterPage 69
12:Motor1 VFcontrol parameterPage 71
13:Motor1 Vector controlparameterPage 75
14:Torque controlPage 77
16:Energy saving controlPage 78
17:Synchronous motor controlPage 79
Display and protection20:User-defined parametersPage 80
21:Keypad and displayPage 82
22:AC Drive configurationPage 84
23:Drive protection function settingPage 87
24:Motor protection parameterPage 90
25:Fault tracking parameterPage 92
26:Fault recording parameterPage 92
27:Monitoring parameterPage 94
Communication30:Modbus communicationPage 95
31:Canopen communicationPage 97
Application40:Process PID FunctionPage 97
41:Sleep functionPage 104
42:Simple PLCPage 105
43:Programmable delay unitPage 107
44:Comparator and logic unit/controllerPage 109
45:Multifunction counterPage 113
Motor 260:Motor2 basic parameterPage 115
61:Motor2 parameterPage 115
62:Motor2 VF control parameterPage 115
63:Motor2 vector control parameterPage 115
China High Capacity 256k TI DSP for Faster Response and Higher Accuracy in VFD530 for PMSM Inverter supplier

High Capacity 256k TI DSP for Faster Response and Higher Accuracy in VFD530 for PMSM Inverter

Inquiry Cart 0