10HP vfd ac 220v single phase input 3 phase output frequency inverter


VEIKONG VFD500 features and technicail data

1, With inside EMC C3 filter and building-block design for IO extension card and different kinds of PG card
2, Top performance in our industry which represent in torque in less than 1hz 0.5hz 0.25hz 0.1hz and 0hz
it can compare with any domestic chinese brand for output torque.
3, Smooth running and stability, support optional LCD keypad and dual display keypad. support PC tools.
4, Support modbus485, canopen, profinet communciation.
5, Low noise on motor and fast response for 0.1S acceleration and deceleration without dead zone
6, Reverse and forward free switching
7, Sleeping function and energy saving function as well as in built PLC programming
8, Tension control and torque mode control
9, Support two group motor parameters which can realize two motor switching control
ItemSpecifiation
InputInuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range-15%~10%
Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating modeSpeed control,Torque control(SVC and VC)
Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

Carrier frequency1kHz~12kHz(Varies depending on the type)
Startup method

Direct start (can be superimposed DC brake); speed tracking start

Stop methodDeceleration stop (can be superimposed DC braking); free to stop
Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN
FunctionKeypadLED Digital keyboard and LCD keypad(option)
Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
HumidityLess than 95%RH, without condensing
VibrationLess than 5.9 m/s2 (0.6 g)
Storage temperature-20°C ~ +60°C
OthersInstallationWall-mounted, floor-controlled cabinet, transmural
Protection levelIP20
cooling methodForced air cooling
EMCCE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment


VEIKONG big power VFD250KW VFD355KW project


PID function


40 Group PID function
r40.00PID final output valueRead only unit:0.1%-
r40.01PID final set valueRead only unit:0.1%-
r40.02PID final feedback valueRead only unit:0.1%-
r40.03PID deviation valueRead only unit:0.1%-
P40.04PID reference source

Unit’s digit:PID main reference source(ref1)

0:Digtital setting

1:AI1

2:AI2

3:AI3(IO expansion board)

4:AI4(IO expansion board)

5:HDI high frequency pulse

6:Communication

Ten’s digit:PID Auxilary reference source(ref2)Same as Unit’s digit

00
P40.05PID given feedback range0.01~655.35100.00
P40.06PID digital setting 00.0~P40.050.0%
P40.07PID digital setting 10.0~P40.050.0%
P40.08PID digital setting 20.0~P40.050.0%
P40.09PID digital setting 30.0~P40.050.0%

When PID reference source is digital setting, PID digital setting 0~3 depends on DI terminal function 43 (preset PID terminal I ) and 44 ( preset PID terminal 2):

preset PID terminal1preset PID terminal 2PID Digital setting value(0.1%)
ineffectiveineffectiveP40.06 * 100.0% / P40.05
ineffectiveeffectiveP40.07 * 100.0% / P40.05
effectiveineffectiveP40.08 * 100.0% / P40.05
effectiveeffectiveP40.09 * 100.0% / P40.05

For example: When AI1 is used as PID feedback, if the full range corresponds to 16.0kg pressure and require PID control to be 8.0kg; then set P40.05 PID feedback range to 16.00, PID digital reference terminal select to P40.06, Set P40.06 (PID preset setting 0) to be 8.00


When PID reference source is digital setting, PID digital setting 0~3 depends on DI terminal function 43 (preset PID terminal I ) and 44 ( preset PID terminal 2):

preset PID terminal1preset PID terminal 2PID Digital setting value(0.1%)
ineffectiveineffectiveP40.06 * 100.0% / P40.05
ineffectiveeffectiveP40.07 * 100.0% / P40.05
effectiveineffectiveP40.08 * 100.0% / P40.05
effectiveeffectiveP40.09 * 100.0% / P40.05

For example: When AI1 is used as PID feedback, if the full range corresponds to 16.0kg pressure and require PID control to be 8.0kg; then set P40.05 PID feedback range to 16.00, PID digital reference terminal select to P40.06, Set P40.06 (PID preset setting 0) to be 8.00


P40.10PID reference source selection0:ref1
1:ref1+ref2
2:ref1-ref2
3:ref1*ref2
4:ref1/ref2
5:Min(ref1,ref2)
6:Max(ref1,ref2)
7(ref1+ref2)/2
8: fdb1and fdb2 switchover
0
P40.11PID feedback source1

Unit’s digit 0:PID feedback source1(fdb1)

0:AI1

1:AI2

2:AI3(option card)

3:AI4(option card)

4: PLUSE(HDI)

5: Communication

6: Motor rated output current

7: Motor rated output frequency

8: Motor rated output torque

9: Motor rated output frequency

Ten’s digit : PID feedback source2 (fdb2)

Same as Unit’s digit

00
P40.13PID feedback function selection0:fdb1
1:fdb1+fdb2
2:fdb1-fdb2
3:fdb1*fdb2
4:fdb1/fdb2
5:Min(fdb1,fdb2)Take fdb1.fdb2 smaller value
6:Max(fdb1,fdb2) Take fdb1.fdb2 bigger value
7: (ref1+ref2)/2
8: fdb1and fdb2 switchover
0
P40.14PID output feature

0: PID output is positive: when the feedback signal exceeds the PID reference value, the output frequency of the inverter will decrease to balance the PID. For example, the strain PID control during wrapup

1: PID output is negative: When the feedback signal is stronger than the PID reference value, the output frequency of the inverter will increase to balance the PID. For example, the strain PID control during wrapdown

0

The PID output characteristic is determined by P40.14 and Di terminal 42 function PID positive/negative switching:

P40.14 = 0 and "42: PID positive/negative switching" terminal is invalid: : PID output characteristic is positive

P40.14 = 0 and "42: PID positive/negative switching" terminal is valid: : PID output characteristic is negative

P40.14 = 1 and "42: PID positive/negative switching" terminal is invalid: : PID output characteristic is negative

P40.14 = 1 and "42: PID positive/negative switching" terminal is valid: : PID output characteristic is positive

P40.15Upper limit of PID output-100.0%~100.0%100.0%
P40.16lower limit of PID output-100.0%~100.0%0.0%
P40.17Proportaional gain KP1

0.00~10.00

The function is applied to the proportional gain P of PID input.

P determines the strength of the whole PID adjuster. The parameter of 100 means that when the offset of PID feedback and given value is 100%, the adjusting range of PID adjust is the Max. frequency (ignoring integral function and differential function).


5.0%
P40.18Integral time TI1

0.01s~10.00s

This parameter determines the speed of PID adjustor to carry out integral adjustment on the deviation of PID feedback and reference.

When the deviation of PID feedback and reference is 100%, the integral adjustor works continuously after the time (ignoring the proportional effect and differential effect) to achieve the Max. Frequency (P01.06) or the Max. Voltage (P12.21). Shorter the integral time, stronger is the

adjustment


1.00s
P40.19Differential time TD1

0.000s~10.000s

This parameter determines the strength of the change ratio when PID adjustor carries out integral adjustment on the deviation of PID feedback and reference.

If the PID feedback changes 100% during the time, the adjustment of integral adjustor (ignoring the proportional effect and differential effect) is the Max. Frequency (P01.06) or the Max. Voltage (P12.21). Longer the integral time, stronger is the adjusting.


0.000s
P40.20Proportaional gain KP20.00~200.0%.5.0%
P40.21Integral time TI2

0.00s (no any integral effect )~20.00s


1.00s
P40.22Differential time TD20.000s~0.100s0.000s
P40.23PID parameter switchover condition

0:no switchover

Do not switch, use KP1, TI1, TD1
1:switchover via DI

Switch by DI terminal

KP1, TI1, TD1 are used when DI terminal No. 41 function is invalid; KP2, TI2, TD2 are used when valid
2:automatic switchover based on deviation

The absolute value of PID command and feedback deviation is less than P40.24, using KP1, TI1, TD1; the absolute value of deviation is greater than P40.25, using KP2, TI2, TD2 parameters; the absolute value of deviation is between P40.24~P40.25, The two sets of parameters are linearly transitioned.

0
P40.24PID parameter switchover devation 10.0%~P40-2520.0%
P40.25PID parameter switchover devation 2P40-24~100.0%80.0%

In some applications, one group PID parameter is not enough, different PID parameters would be adopted

according to the situation.

The function codes are used to switch two groups PID parameter. The setting mode of the regulator

parameters P40.20~P40.22 is similar as P40.17~P40.19’s.

Two groups PID parameter can be switched via DI terminal, or switched according to PID deviation

automatically.

When selection is automatic switching: when the deviation absolute value between given and feedback is

smaller than P40.24 (PID parameter switching deviation 1), PID parameter selection is group 1. When the

deviation absolute value between given and feedback is bigger than P40.25 (PID parameter switching

deviation 2), PID parameter selection is group 2. When the deviation absolute value between given and

feedback is between P40.24 and P40.25, PID parameter is the linear interpolation of two groups PID

parameter, showed as below

parameter switching diagram