Home /Motors /

90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor

90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor

Brand Name:VEIKONG
Certification:CE, ROHS
Model Number:VFD500-045G/055GT4B
Minimum Order Quantity:1
Delivery Time:depends on quantities
Payment Terms:T/T, Western Union, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

45kw 60hp ac drive inverter vfd for pump fan air compressor vfd


1, With inside EMC C3 filter and building-block design for IO extension card and different kinds of PG card
2, Top performance in our industry which represent in torque in less than 1hz 0.5hz 0.25hz 0.1hz and 0hz
it can compare with any domestic chinese brand for output torque.
3, Smooth running and stability, support optional LCD keypad and dual display keypad. support PC tools.
4, Support modbus485, canopen, profinet communciation.
5, Low noise on motor and fast response for 0.1S acceleration and deceleration without dead zone
6, Reverse and forward free switching
7, Sleeping function and energy saving function as well as in built PLC programming
8, Tension control and torque mode control
9, Support two group motor parameters which can realize two motor switching control
ItemSpecifiation
InputInuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range-15%~10%
Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating modeSpeed control,Torque control(SVC and VC)
Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

Carrier frequency1kHz~12kHz(Varies depending on the type)
Startup method

Direct start (can be superimposed DC brake); speed tracking start


VEIKONG inverter work together with famous brands


Modbus and Canopen communication parameter


30 Group Modbus communication parameter
P30.00Communication type

0:Modbus;

1:Canopen

0
P30.01Drive Address

1~247

Different slaves on the same network should set different local addresses;

0 is the broadcast address, all slave inverters can be identified

1
P30.02Modbus baud rate

0:1200 bps; 1:2400 bps

2:4800 bps; 3:9600 bps

4:19200 bps; 5:38400 bps

6:57600 bps; 7:115200 bps

3
P30.03Modbus data format

0: 1-8-N-1

(1 start bit +8 data bits +1 stop bits )

1: 1-8-E-1

(1start bit +8 data bits +1 even parity +1 stop bit)

2: 1-8-0-1

(1 star bit+8 data bits +1odd parity+1 stop bits)

3: 1-8-N-2

(1 star bit+8 data bits+2 stop bits)

4: 1-8-E-2

(1 star bits+8 data bit+1 even parity+2 stop bits)

5: 1-8-0-2

(1 start bit +8 data bits+1 odd parity+2 stop bits)

0
P30.04Modbus response delay1~20msThe delay time of the local to answer the master2ms
P30.05Modbus overtime0.0s(disabled)~60.0s(works for master-slave system) When this function code effective,if slave do not receive data from master overtime,it will trip as Er.4850.0s
r30.06Number of frames received by ModbusEach time a frame is received, this value is incremented by 1,0 to 65535 cycles.-
r30.07Number of frames that Modbus has sentEach time a frame is sent, this value is incremented by 1,0 to 65,536 cycles.-
r30.08Number of error frames received by ModbusEach time an CRC error frame is received, this value is incremented by 1,0 to 65535 cycles; it can be used to judge the degree of communication interference.-
P30.09Modbus master-slave option0: Slave
1: Master(sent by broadcast )
0
P30.10Slave memory when inverter as master1~9 corresponds to 0x7001~0x70091
P30.11Data sent by Master

0:output frequency

1:set frequency

2:output torque

3:set torque

4:PID setting

5:PID feedback

6:output current

0
P30.12Sending interval of Master0.010~10.000sAs a master, after sending one frame of data, the next frame of data is sent after this delay.0.1s
P30.13Receiving proportaionality factor of slave-10.000~10.000The values of slave registers 0x7001 and 0x7002 take effect after passing through this scaling factor1.00
P30.14Communication special register speed unit

0: 0.01%

1: 0.01Hz

2: 1Rpm

Some units of specific communication registers can be set by this parameter. See Appendix A for details.

0
P30.15Modbus response characteristics

When the format of the received frame is a write register, this parameter can be set to reply to the host.

0: Reply to the host (standard Modbus protocol)

1: Do not reply to the host (non-standard Modbus protocol)

0
31 Group Canopen communication parameter
P31.00CANopen communication address1 ~ 1271
P31.01CANopen Baud rate

0:100k

1:125k

2:250k

3:500k

4:1M

3
P31.02CANopen overtime1ms ~ 20ms4ms
r31.07CANopen version numberDisplay the version number of the CANopen card-
r31.08CANopen Working status

0: Initialisation status

1: Disconnected

2: Connecting/Preparing-

3: Stopped

4: Operational status

5: Pre_operational

-
r31.10CANopen receive error countThe number of error frames received by CANopen is not saved after power off-
r31.11CANopen send error countThe number of frames sent by CANopen is not saved after power off-
r31.12CANopen receive frame numberThe number of frames received by CANopen is not saved after power off-
r31.14CANopen send frame numberThe number of frames sent by CANopen is not saved after power off-
China 90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor supplier

90A 45kw 60hp Vfd Fan Controller / Air Compressor VFD For Single Phase Motor

Inquiry Cart 0