5.5KW vector control VFD for crusher application ac drive inverters

Brand Name:VEIKONG
Certification:CE
Model Number:VFD500-PV
Minimum Order Quantity:1
Delivery Time:3 days, depend on the order quantity
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Supplier`s last login times: within 20 hours
Product Details Company Profile
Product Details

5.5KW vector control VFD for crusher application ac drive inverters



High performance

1. More Accurate Motor Autotuning
2. Advanced open and close loop vector control
3. Perfect voltage and current control, reducing the fault protection times
4 Multiple braking modes and instant stopping
5. 0.75kW~7100kW(Three Phase 400V)


Features

  1. High-performance vector universal platform, brand new motor control algorithm.
  2. Synchronous and asynchronous drives are integrated, open loop and closed loop are comprehensive.
  3. Software and hardware modular design requirements, strong expansion capabilities.
  4. Rich interface accessories, covering various applications.
  5. Book design, save installation space.
  6. Optimize the convenient keyboard design, support the new external keyboard.
  7. The upper and lower straight ventilation ducts are designed to dissipate heat by DC fans.
  8. PCB spraying three-proof paint to ensure product stability and reliability.

VFD500 parameter distribution list


ClassificationParameter groupPage
Common parameters00:Basic functionPage 30
01:Frequency source selectionPage 32
02:Start and stopPage 37
03:Ramp and S curvePage 39
04: Analog and pulse inputPage 41
05:Analog and pulse outputPage 45
06: Multi-function Digital input (DI)Page 46
07: Multi-function Digital output(DO)Page 49
08:Digital Output settingPage 51
Motor control10:Encoder typePage 53
11:Motor1 parmeterPage 54
12:Motor1 VFcontrol parameterPage 56
13:Motor1 Vector controlparameterPage 58
14:Torque controlPage 59
16:Energy saving controlPage 61
Display and protection20:User-defined parametersPage 62
21:Keypad and displayPage 63
22:AC Drive configurationPage 65
23:Drive protection function settingPage 67
24:Motor protection parameterPage 70
25:Fault tracking parameterPage 72
26:Fault recording parameterPage 72
27:Monitoring parameterPage 74
Communication30:Modbus communicationPage 75
Application40:Process PID FunctionPage 77
41:Sleep functionPage 81
42:Simple PLCPage 82
43:Programmable delay unitPage 84
44:Comparator and logic unit/controllerPage 86
45:Multifunction counterPage 90
Motor 260:Motor2 basic parameterPage 91
61:Motor2 parameterPage 91
62:Motor2 VF control parameterPage 92
63:Motor2 vector control parameterPage 92

Techincal Parameters:


ItemSpecifiation
InputInuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range-15%~10%
Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating modeSpeed control,Torque control(SVC and VC)
Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;


Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure


VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

Carrier frequency1kHz~12kHz(Varies depending on the type)
Startup methodDirect start (can be superimposed DC brake); speed tracking start
Stop methodDeceleration stop (can be superimposed DC braking); free to stop
Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parameters free switching, software swap output wiring, terminals UP / DOWN

VEIKONG VFD replace famous brand VFD



China 5.5KW vector control VFD for crusher application ac drive inverters supplier

5.5KW vector control VFD for crusher application ac drive inverters

Inquiry Cart 0