Home /Power Cables /

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

Brand Name:DONGJIAXIN
Certification:QS
Model Number:YJV
Minimum Order Quantity:Negotiable
Delivery Time:7-15 working days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: No.8 Huamei Road,Songgang Sub-District,Baoan District, SHENZHEN, Guangdong 518000, China
Supplier`s last login times: within 13 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Copper Conductor XLPE Insulation and PVC Jacket Power Cable

Application:

1kV for Fixed installations such as distribution networks or industrial installations.

Construction:

Core Conductor annealed copper (stranded core)
Popular sizes 2~5core x1.5~630mm²
Cable conductor stranded annealed copper
Insulation XLPE
Jacket PVC
Temperature rating -25C up to +90℃
Voltage suitable 0.6/1kV
Fire performance IEC 60332-1
Approval QS in China

Advantage:

It has excellent thermal-mechanical properties, excellent electrical properties and chemical corrosion resistance, and also has the advantages of simple structure, light weight, and no drop limit for laying.

Standards&Certificates:

IEC 60502-1

▼ Technical parameters:

1. Single Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
1×1.5 1 0.7 1.4 5.2 12.1
1×2.5 1 0.7 1.4 5.6 7.41
1×4 1 0.7 1.4 6.0 4.61
1×6 1 0.7 1.4 6.5 3.08
1×10 7 0.7 1.4 7.6 1.83
1×16 7 0.7 1.4 8.6 1.15
1×25 7 0.9 1.4 10.2 0.727
1×35 7 0.9 1.4 11.2 0.524
1×50 10 1.0 1.4 12.5 0.387
1×70 14 1.1 1.4 14.3 0.268
1×95 19 1.1 1.5 16.5 0.193
1×120 24 1.2 1.5 18.2 0.153
1×150 30 1.4 1.6 20.1 0.124
1×185 37 1.6 1.6 22.2 0.0991
1×240 48 1.7 1.7 24.9 0.0754
1×300 61 1.8 1.8 27.5 0.0601
1×400 61 2.0 1.9 30.8 0.0470
1×500 61 2.2 2.0 34.3 0.0366
1×630 61 2.4 2.2 41.3 0.0283

2. 2 Core&3 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
2×1.5 1 0.7 1.8 8.9 12.1
2×2.5 1 0.7 1.8 9.7 7.41
2×4 1 0.7 1.8 10.6 4.61
2×6 1 0.7 1.8 11.6 3.08
2×10 7 0.7 1.8 13.8 1.83
2×16 7 0.7 1.8 15.7 1.15
2×25 7 0.9 1.8 18.9 0.727
2×35 7 0.9 1.8 20.9 0.524
2×50 10 1.0 1.8 24.6 0.387
2×70 14 1.1 1.8 28.2 0.268
2×95 19 1.1 1.9 32.4 0.193
2×120 24 1.2 2.0 35.8 0.153
2×150 30 1.4 2.2 39.6 0.124
2×185 37 1.6 2.3 44.0 0.0991
2×240 48 1.7 2.5 49.4 0.0754
2×300 61 1.8 2.6 54.3 0.0601
2×400 61 2.0 2.9 61.0 0.0470
2×500 61 2.2 3.1 68.4 0.0366
2×630 61 2.4 3.3 82.0 0.0283
3×1.5 1 0.7 1.8 9.4 12.1
3×2.5 1 0.7 1.8 10.2 7.41
3×4 1 0.7 1.8 11.2 4.61
3×6 1 0.7 1.8 12.2 3.08
3×10 7 0.7 1.8 14.6 1.83
3×16 7 0.7 1.8 16.7 1.15
3×25 7 0.9 1.8 20.1 0.727
3×35 7 0.9 1.8 22.3 0.524
3×50 10 1.0 1.8 26.2 0.387
3×70 14 1.1 1.9 30.3 0.268
3×95 19 1.1 2.0 34.6 0.193
3×120 24 1.2 2.1 38.5 0.153
3×150 30 1.4 2.3 42.6 0.124
3×185 37 1.6 2.4 47.3 0.0991
3×240 48 1.7 2.6 53.1 0.0754
3×300 61 1.8 2.7 58.2 0.0601
3×400 61 2.0 3.0 65.6 0.0470
3×500 61 2.2 3.2 73.5 0.0366
3×630 61 2.4 3.5 88.2 0.0283

3. 4 Core&5 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×1.5 1 0.7 1.8 10.1 12.1
4×2.5 1 0.7 1.8 11.0 7.41
4×4 1 0.7 1.8 12.1 4.61
4×6 1 0.7 1.8 13.3 3.08
4×10 7 0.7 1.8 16.0 1.83
4×16 7 0.7 1.8 18.3 1.15
4×25 7 0.9 1.8 22.1 0.727
4×35 7 0.9 1.8 24.6 0.524
4×50 10 1.0 1.8 28.8 0.387
4×70 14 1.1 2.0 33.4 0.268
4×95 19 1.1 2.1 38.4 0.193
4×120 24 1.2 2.3 43.0 0.153
4×150 30 1.4 2.4 47.3 0.124
4×185 37 1.6 2.6 52.7 0.0991
4×240 48 1.7 2.8 59.0 0.0754
4×300 61 1.8 3.0 65.1 0.0601
4×400 61 2.0 3.3 73.3 0.0470
4×500 61 2.2 3.5 82.0 0.0366
4×630 61 2.4 3.8 98.6 0.0283
5×1.5 1 0.7 1.8 10.9 12.1
5×2.5 1 0.7 1.8 11.9 7.41
5×4 1 0.7 1.8 13.1 4.61
5×6 1 0.7 1.8 14.5 3.08
5×10 7 0.7 1.8 17.4 1.83
5×16 7 0.7 1.8 20.0 1.15
5×25 7 0.9 1.8 24.3 0.727
5×35 7 0.9 1.8 27.0 0.524
5×50 10 1.0 1.9 31.9 0.387
5×70 14 1.1 2.1 36.9 0.268
5×95 19 1.1 2.2 42.5 0.193
5×120 24 1.2 2.4 47.5 0.153
5×150 30 1.4 2.6 52.5 0.124
5×185 37 1.6 2.8 58.4 0.0991
5×240 48 1.7 3.0 65.5 0.0754
5×300 61 1.8 3.2 72.3 0.0601
5×400 61 2.0 3.5 81.2 0.0470
5×500 61 2.2 3.8 91.2 0.0366
5×630 61 2.4 4.1 109.5 0.0283

4. 3+1 Core & 3+2 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 1.8 10.8 7.41
3×4+1×2.5 1 0.7 1.8 11.8 4.61
3×6+1×4 1 0.7 1.8 13.0 3.08
3×10+1×6 7 0.7 1.8 15.3 1.83
3×16+1×10 7 0.7 1.8 17.7 1.15
3×25+1×16 7 0.9 1.8 21.2 0.727
3×35+1×16 7 0.9 1.8 23.0 0.524
3×50+1×25 10 1.0 1.8 27.4 0.387
3×70+1×35 14 1.1 1.9 31.5 0.268
3×95+1×50 19 1.1 2.1 36.1 0.193
3×120+1×70 24 1.2 2.2 40.5 0.153
3×150+1×70 30 1.4 2.3 43.8 0.124
3×185+1×95 37 1.6 2.5 49.2 0.0991
3×240+1×120 48 1.7 2.6 55.0 0.0754
3×300+1×150 61 1.8 2.8 60.5 0.0601
3×400+1×185 61 2.0 3.1 68.1 0.0470
3×500+1×240 61 2.2 3.3 76.3 0.0366
3×630+1×300 61 2.4 3.6 90.1 0.0283
3×2.5+2×1.5 1 0.7 1.8 11.5 7.41
3×4+2×2.5 1 0.7 1.8 12.6 4.61
3×6+2×4 1 0.7 1.8 13.9 3.08
3×10+2×6 7 0.7 1.8 16.2 1.83
3×16+2×10 7 0.7 1.8 19.0 1.15
3×25+2×16 7 0.9 1.8 22.6 0.727
3×35+2×16 7 0.9 1.8 24.2 0.524
3×50+2×25 10 1.0 1.8 29.1 0.387
3×70+2×35 14 1.1 2.0 33.3 0.268
3×95+2×50 19 1.1 2.1 38.2 0.193
3×120+2×70 24 1.2 2.3 43.3 0.153
3×150+2×70 30 1.4 2.4 46.3 0.124
3×185+2×95 37 1.6 2.5 52.0 0.0991
3×240+2×120 48 1.7 2.7 58.1 0.0754
3×300+2×150 61 1.8 2.9 64.2 0.0601
3×400+2×185 61 2.0 3.2 72.1 0.0470
3×500+2×240 61 2.2 3.5 80.9 0.0366
3×630+2×300 61 2.4 3.8 94.7 0.0283

5. 4+1 Core

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
4×2.5+1×1.5 1 0.7 1.8 11.7 7.41
4×4+1×2.5 1 0.7 1.8 12.9 4.61
4×6+1×4 1 0.7 1.8 14.2 3.08
4×10+1×6 7 0.7 1.8 16.8 1.83
4×16+1×10 7 0.7 1.8 19.5 1.15
4×25+1×16 7 0.9 1.8 23.4 0.727
4×35+1×16 7 0.9 1.8 25.6 0.524
4×50+1×25 10 1.0 1.9 30.6 0.387
4×70+1×35 14 1.1 2.0 35.0 0.268
4×95+1×50 19 1.1 2.2 40.5 0.193
4×120+1×70 24 1.2 2.3 45.3 0.153
4×150+1×70 30 1.4 2.5 49.4 0.124
4×185+1×95 37 1.6 2.6 55.2 0.0991
4×240+1×120 48 1.7 2.9 61.9 0.0754
4×300+1×150 61 1.8 3.1 68.3 0.0601
4×400+1×185 61 2.0 3.4 76.7 0.0470
4×500+1×240 61 2.2 3.6 86.0 0.0366
4×630+1×300 61 2.4 3.9 102.1 0.0283

Company information:

30 years of experience in R & D, production and sales of wire and cable.

Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.

Annual revenue is about 500 million US dollars.

CNAS laboratory, more than 100 testing reports.

Products are widely used in real estate, municipal, industrial support, mobile communications etc

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

FAQ

* How to assure the quality of products?

1. Most of our products have certification.

2. Our Lab staff will test the material and check the process card before production.

3. The O.D tester is testing all the time during production, and the production line is always under control.

4. The product will be tested by Lab staff after production.

* Do you offer free samples or not?

1. If we have inventory about the sample you need and the total amount is not large, it's free.

2. If we don't have inventory, according to our company's rule, sample and freight costs need to be paid by your esteemed company. And we will return the sample cost to you when you place the first order with us. Thanks for your support.

* When I want customized products, how to do it?

We have professional equipment, technicians & skilled employees, OEM & customized service is welcome. Drawings or samples are required. Of course, the purchased quantity should meet our MOQ.

China Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable supplier

Stranded PVC Insulated Power Cable , YJV N2XY 3 Core 240 185 mm2 Power Cable

Inquiry Cart 0