Ce Suction Machine Small Dc Vacuum Pump 3.7vdc

Brand Name:Zhaoli
Certification:CE, ROHS, REACH
Model Number:DC2430PD02A
Minimum Order Quantity:2000
Delivery Time:25-45 days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Zhongshan Guangdong China
Address: No. 10, Fuju Street, Fusha Town, Zhongshan, Guangdong, China 528434
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

DC Vacuum Pump Small DC Pump For Suction Machine 3.7VDC 2.0L/M


  • Operating condition
Test EnvironmentAmbient temperature of 20℃ and relative humidity of 65%RH.
PositionHorizontal
LoadAir pressure 300mmHg
Operating condition5℃~45℃, RH 30%~85%
Storage condition-20℃~60℃, RH 30%~85%
  • Performance
Rated voltage3.70VDC
Operating voltage3.0 - 4.5 VDC
Rated current

<650 mA;The highest current is less than 650mA while

pressurizing with DC3.7V from 0 to 300mmHg

Inflation timeAt DC3.7V to pressurize in a 100cc tank from 0 to 200 mmHg, Inflation time 6 seconds.
Air flowAt DC3.7V ,the air flow is more than 2.0L/min with no load..
Max pressureThe maximum pressure value shall be more than 400mmHg while pressurizing with DC 3.7 V tank from 0 till dead-head pressure value
Max vacuumThe maximum vacuum value shall be Less than-450mmHg while pressurizing with DC 3.7V tank from 0 till dead-head vocuum value.
NoisePutting a 5 cm sponge under the pump,and placing it about 30 cm away from the noise meter,The evaluated noise level shall be less then 60dB while pressurizing with DC 3.7V from 0 to 200mmHg.
  • Environmental Tests
Low-temperature characteristicPutting the pump in the temperature at negative 20℃ for 72 hours;then taking it out and putting it in a room temperature at 20± 5℃ for 2 hours,Under this circumstance,running through performance test and finding out that the pump still performs well.
High-temperature characteristicPutting the pump in the temperature at 60℃ for 72 hours; then taking it out and putting it in a room temperature at 20 ± 5 ℃ for 2 hours,Under this circumstance,running through perforamance and finding out that the pump still performs well.
High-temperature & High humidityPutting the pump in the temperature at 60℃ and the humidity at 95% for 72 hours;then taking it out and putting it in a room temperature at 20 ± 5 ℃ for 2 hours.Under this circumstance,running through performance test and finding out that the pump still performs well.
Temperature & humidity cycle testAfter doing the temperature and humidity cycle test,-20℃* 2Hr → +25℃* 1Hr→ +60℃ 85%RH* 2Hr →+25℃*1Hr,for twelve times,the pump shall still perform the same functions proved by running through performance test.
Life test

In a 500CC tank,pressurizing for 10 seconds , stopping for 2

seconds,exhaust for 5 seconds is as one cycle,Doing it for 30,000

times, then examine the pump by testing performance and figure out than the pump is still in a good function.


Drawing:


Application: Portable suction pump





China Ce Suction Machine Small Dc Vacuum Pump 3.7vdc supplier