Home /Mixing Equipment /

High Precision Fluke Multifunction Calibrator TD1880 For Electrical Measuring

High Precision Fluke Multifunction Calibrator TD1880 For Electrical Measuring

Brand Name:TUNKIA
Minimum Order Quantity:negotiation
Payment Terms:negotiation
Place of Origin:China
Price:negotiation
Packaging Details:Standard
Contact Now

Add to Cart

Verified Supplier
Supplier`s last login times: within 26 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details
TD1880 High-Precision Multi-Product Calibrator

Introduction

  • TD1880, a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC/DC voltage, current, phase adjustment and power, and also has the functions of pulse output and simulating DC resistance, thermocouple (TC), thermal resistance (RTD) and capacitance. Applied to calibrate 6 and below digits multimeters or other electrical measuring instruments.

Reference

  • JJG 124-2005 Verification Regulation of Amperemeters, Voltmeters, Wattmeters and Ohmmeters.

  • JJF 1587-2016 Calibration Specification for Multimeters

  • JJF 1284-2011 Calibration Specification of Calibrators for Electrical Meters

  • JJF 1638-2017 Calibration specification of multifunctional standard source

Features

  • Electrical Parameters Output: Voltage is up to 1100 V, current is up to 30 A at a frequency 10 Hz ~ 500 kHz.

  • Resistance Simulation: Continuously variable range, 1 ~ 1100 M, pulse output range: 1 Hz ~ 2 MHz.

  • The output current has high stability (the typical value is better than 10 ppm/h) and high accuracy (the typical value is 50 ppm/a), and its measurement accuracy is higher than the international similar products.

  • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

  • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

  • TC and RTD simulation: Support for simulation of up to 8 types of TC and 6 types of RTD.

  • Strong load capacity of AC, can drive various types of analogue meters and digital meters, so the applicable range of measured instruments is very wide.

  • The protection of voltage and current sources ensures high reliability under complex conditions.

  • Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.

  • Transmitter Measurement (Option): Measure the secondary DC signal of the transmitters.

  • Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.

Specification

AC Voltage Output

Range Resolution Frequency (Hz) Accuracy (k = 2, ppm*RD +μV)

Max. Load

Current (mA)

90 Days

(23 ±5) °C

1 Year

(23 ±5) °C

30 mV 100 nV 10 ≤ F≤ 45 600 + 6 800 + 6 50
45 < F < 400 80 + 5 100 + 5
400 < F < 10 k 80 + 10 100 + 10
10 k < F < 20 k 160 + 10 200 + 10
20 k < F < 50 k 800 + 10 1000 + 10
50 k < F < 100 k 2800 + 12 3500 + 12
100 k < F < 500 k 6000 + 50 8000 + 50
100 mV 1 μV 10 ≤ F≤ 45 250 + 8 300 + 8 50
45 < F < 400 80 + 5 100 + 5
400 < F < 10 k 80 + 10 100 + 10
10 k < F < 20 k 80 + 10 200 + 10
20 k < F < 50 k 280 + 10 350 + 10
50 k < F < 100 k 640 + 10 800 + 10
100 k < F < 500 k 1600 + 70 2000 + 70
300 mV 1 μV 10 ≤ F≤ 45 250 + 8 300 + 8 100
45 < F < 10 k 80 + 10 100 + 10
10 k < F < 20 k 80 + 10 200 + 10
20 k < F < 50 k 280 + 10 350 + 10
50 k < F < 100 k 640 + 10 800 + 10
100 k < F < 500 k 1600 + 70 2000 + 70

1 V

10 μV 10 ≤ F≤ 45 250 + 50 300 + 50 100
45 < F < 400 40 + 20 50 + 20
400 < F < 10 k 80 + 20 100 + 20
10 k < F < 20 k 160 + 20 200 + 20
20 k < F < 50 k 280 + 20 350 + 20
50 k < F < 100 k 640 + 20 800 + 20
100 k < F < 500 k 2000 + 600 2400 + 600
3 V 10 μV 10 ≤ F≤ 45 250 + 50 300 + 50 100
45 < F < 400 40 + 50 50 + 50
400 < F < 2 k 64 + 50 80 + 50
2 k < F < 10 k 80 + 50 100 + 50
10 k < F < 20 k 160 + 50 200 + 50
20 k < F < 50 k 280 + 50 350 + 50
50 k < F < 100 k 640 + 50 800 + 50
100 k < F < 500 k 2000 + 600 2400 + 600
10 V 100 μV 10 ≤ F≤ 15 250 + 30000 300 + 30000 100
15 < F < 45 250 + 650 300 + 650
45 < F < 400 40 + 150 50 + 150
400 < F < 2 k 64 + 150 80 + 150
2 k < F < 10 k 80 + 150 100 + 150
10 k < F < 20 k 160 + 150 200 + 150
20 k < F < 50 k 280 + 150 350 + 150
30 V 100 μV 10 ≤ F≤ 15 250 + 80000 300 + 30000 250
15 < F < 45 250 + 650 300 + 650
45 < F < 400 40 + 500 50 + 500
400 < F < 2 k 64 + 500 80 + 500
2 k < F < 10 k 80 + 500 100 + 500
10 k < F < 20 k 160 + 500 200 + 500
20 k < F < 50 k 280 + 500 350 + 500
100 V 1 mV 15 < F < 45 250 + 2000 300 +2000 250
45 < F < 400 40 + 1000 50 +1000
400 < F < 2 k 64 + 1000 80 + 1000
2 k < F < 10 k 80 + 1000 100 + 1000
10 k < F < 20 k 160 + 1000 200 + 1000
20 k < F < 50 k 280 + 1000 350 + 1000
300 V 1 mV 15 < F < 45 250 + 6000 300 + 6000 100
45 < F < 400 50 + 5000 50 + 5000
400 < F < 2 k 80 + 5000 80 + 5000
2 k < F < 10 k 80 + 5000 100 + 5000
10 k < F < 20 k 160 + 5000 200 + 5000
20 k < F < 50 k 280 + 5000 350 + 5000
1000 V

10 mV

45 ≤ F≤ 400 80 + 10000 100 + 10000 30
400 < F < 2 k 96 + 10000 120 + 10000
2 k < F < 10 k 120 + 10000 150 + 10000
  • Output Range: 3 mV ~ 1100 V; Display: 7 digits;

  • Distortion: <0.5 %;<1 % @ 10 mV…1 V ranges

  • Protection: Short-circuit protection, overload protection.

AC Current Output

Range Resolution Frequency (Hz) Accuracy (k = 2, ppm*RD +μV)

Max. Load

Current (mA)

90 Days

(23 ±5) °C

1 Year

(23 ±5) °C

300 μA 1 nA 10 ≤ F≤ 20 400 + 0.2 500 + 0.2 30
20 < F < 45 300 + 0.1 350 + 0.1
45 < F < 400 240 + 0.1 300 + 0.1
400 < F < 2 k 320 + 0.2 400 + 0.2
2 k < F < 10 k 400 + 0.5 500 + 0.5
10 k < F < 20 k 4000 + 0.6 5000 + 0.6
20 k < F < 50 k 6400 + 0.7 8000 + 0.7
1 mA 10 nA 10 ≤ F≤ 20 400 + 0.5 500 + 0.5 30
20 < F < 45 200 + 0.1 250 + 0.1
45 < F < 400 160 + 0.1 200 + 0.1
400 < F < 2 k 160 + 0.2 200 + 0.2
2 k < F < 10 k 240 + 0.5 300 + 0.5
10 k < F < 20 k 2400 + 0.6 3000 + 0.6
20 k < F < 50 k 5600 + 0.7 7000 + 0.7
3 mA 10 nA 10 ≤ F≤ 20 400 + 1.5 500 + 1.5 30
20 < F < 45 200 + 0.1 250 + 0.1
45 < F < 400 160 + 0.1 200 + 0.1
400 < F < 2 k 160 + 0.2 200 + 0.2
2 k < F < 10 k 240 + 0.5 300 + 0.5
10 k < F < 20 k 1600 + 0.6 2000 + 0.6
20 k < F < 50 k 4800 + 0.7 6000 + 0.7
10 mA 100 nA 10 ≤ F≤ 20 400 + 5 500 + 5 30
20 < F < 45 200 + 0.5 250 + 0.5
45 < F < 400 80 + 0.5 100 + 0.5
400 < F < 2 k 160 + 1 200 + 1
2 k < F < 10 k 400 + 2 500 + 2
10 k < F < 20 k 1600 + 3 2000 + 3
20 k < F < 50 k 4800 + 4 6000 + 4
30 mA 100 nA 10 ≤ F≤ 20 400 + 15 500 + 15 30
20 < F < 45 200 + 2 250 + 2
45 < F < 400 80 + 2 100 + 2
400 < F < 2 k 160 + 3 200 + 3
2 k < F < 10 k 400 + 5 500 + 5
10 k < F < 20 k 1600 + 6 2000 + 6
20 k < F < 50 k 4800 + 7 6000 + 7
100 mA 1 μA 10 ≤ F≤ 20 400 + 50 500 + 50 30
20 < F < 45 200 + 5 250 + 5
45 < F < 400 40 + 5 50 + 5
400 < F < 2 k 80 + 10 100 + 10
2 k < F < 10 k 160 + 20 200 + 20
10 k < F < 20 k 800 + 30 1000 + 30
20 k < F < 30 k 2400 + 40 3000 + 40
30 k < F < 50 k 5000 + 40 6000 + 40
1 A 10 μA 10 ≤ F≤ 20 400 + 500 500 + 500 15
20 < F < 45 200 + 20 250 + 20
45 < F < 400 40 + 50 50 + 50
400 < F < 2 k 50 + 100 50 + 100
2 k < F < 10 k 160 + 500 200 + 500
10 k < F < 20 k 800 + 600 1000 + 600
20 k < F < 30 k 2400 + 700 3000 + 700
3 A 10 μA 10 ≤ F≤ 20 400 + 1500 500 + 1500 10
20 < F < 45 200 + 100 250 + 100
45 < F < 400 40 + 100 50 + 100
400 < F < 2 k 80 + 100 100 + 100
2 k < F < 10 k 160 + 500 200 + 500
10 A 100 μA 45 < F < 400 40 + 200 50 + 200 2.5
400 < F < 2 k 80 + 200 100 + 200
2 k < F < 10 k 160 + 500 200 + 500
30 A 100 μA 45 ≤ F≤ 400 80 + 600 100 + 600 2
400 < F < 2 k 80 + 600 100 + 600
2 k < F < 5 k 160 + 1500 200 + 1500
  • Output Range: 30 μA ~ 30 A; Display: 7 digits;

  • Distortion: <0.5 %;<1 % @ 300 μA…10 mA ranges

  • Protection: Short-circuit protection, overload protection.

DC Voltage Output

Range Accuracy (K = 2) (ppm*RD + μV)

Max. Load Current

(mA)

Ripple Coefficient

(%)

24 Hours 90 Days 1 Year
30 mV 15 + 2 24 + 2 30 + 2 50 < 0.5
100 mV 12 + 2 20 + 2 25 + 2 50 < 0.5
300 mV 10 + 2 16 + 2 20 + 2 100 < 0.5
1 V 10 + 2 16 + 2 20 + 2 100 < 0.5
3 V 8 + 5 12 + 5 15 + 5 100 < 0.5
10 V 8 + 10 12 + 10 15 + 10 100 < 0.5
30 V 8 + 20 12 + 20 15 + 20 250 < 0.5
100 V 10 + 100 16 + 100 20 + 100 250 < 0.5
300 V 10 + 300 16 + 300 20 + 300 100 < 0.5
1000 V 10 + 1500 16 + 1500 20 + 1500 30 < 0.5
  • Output Range: ±(3 mV ~ 1100 V); Resolution: 0.0005 %*RG; Display: 7 digits

  • Range Switching: Automatic or Manual.

DC Current Output

Range

Accuracy (K = 2)

(ppm*RD + ppm*RG)

Max. Load Voltage

(V)

Ripple Coefficient

(%)

24 Hours

90 Days

1 Year
30 μA 50 + 0.01 80 + 0.01 100 + 0.01 11 < 0.5
100 μA 50 + 0.02 80 + 0.02 100 + 0.02 11 < 0.5
300 μA 50 + 0.02 80 + 0.02 100 + 0.02 11 < 0.5
1 mA 25 + 0.05 40 + 0.05 50 + 0.05 11 < 0.5
3 mA 25 + 0.05 40 + 0.05 50 + 0.05 11 < 0.5
10 mA 25 + 0.2 40 + 0.2 50 + 0.2 11 < 0.5
30 mA 25 + 0.5 40 + 0.5 50 + 0.5 11 < 0.5
100 mA 25 + 1 40 + 1 50 + 1 11 < 0.5
1 A 25 + 20 40 + 20 50 + 20 4 < 0.5
3 A 25 + 50 40 + 50 50 + 50 4 < 0.5
10 A 25 + 200 40 + 200 50 + 200 4 < 0.5
30 A 30 + 600 48 + 600 60 + 600 3.5 < 0.5
  • Output Range: ±(3 μA ~ 30 A); Resolution: 0.0005 %*RG; Display: 7 digits

  • Range Switching: Automatic or Manual.

AC/DC Power Output

DC Power Range Combination of DC voltage range and DC current range.
Accuracy DC voltage accuracy + DC current accuracy.

AC Power

(45 Hz ~ 65 Hz)

Range Combination of 30 V...300 V range and 10 mA…30 A range.
Accuracy Range of 10 mA…30 mA: 0.05 %*FS
Range of 100 mA…30 A: 0.02 %*FS
Power Factor -1.0000…0.0000…+1.0000
  • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

Capacitance

Range Accuracy (k = 2) (%*RD+ nF or μF) Resolution Allowable Frequency
1.1 nF ~ 3.2999 nF 0.5 + 0.04 nF 0.1 pF 10 Hz ~ 3 kHz
3.3 nF ~ 10.9999 nF 0.25 + 0.04 nF 0.1 pF 10 Hz ~ 1 kHz
11 nF ~ 32.9999 nF 0.25 + 0.4 nF 0.1 pF 10 Hz ~ 1 kHz
33 nF ~ 109.999 nF 0.25 + 0.4 nF 1 pF 10 Hz ~ 1 kHz
110 nF ~ 329.999 nF 0.25 + 0.3 nF 1 pF 10 Hz ~ 1 kHz
330 nF ~ 1.09999 μF 0.25 + 1 nF 10 pF 10 ~ 600 Hz
1.1 μF ~ 3.29999 μF 0.25 + 3 nF 10 pF 10 ~ 300 Hz
3.3 μF ~ 10.9999 μF 0.25 + 10 nF 100 pF 10 ~ 150 Hz
11 μF ~ 32.9999 μF 0.40 + 30 nF 100 pF 10 ~ 120 Hz
33 μF ~ 109.999 μF 0.45 + 100 nF 1 nF 10 ~ 80 Hz
110 μF ~ 329.999 μF 0.45 + 300 nF 1 nF 0 ~ 50 Hz
330 μF ~ 1.09999 mF 0.45 + 1 μF 10 nF 0 ~ 20 Hz
1.1 mF ~ 3.29999 mF 0.45 + 3 μF 10 nF 0 ~ 6 Hz
3.3 mF ~ 10.9999 mF 0.45 + 10 μF 100 nF 0 ~ 2 Hz
11 mF ~ 30 mF 0.75 + 30 μF 100 nF 0 ~ 0.6 Hz

Resistance

Range Allowable Current Accuracy (k = 2), ppm*RD +Ω
24 Hours

90 Days

1 Year
10 Ω 1 mA ~ 150 mA 20 + 0.01 32 + 0.01 40 + 0.01
20 Ω 1 mA ~ 150 mA 15 + 0.015 24 + 0.015 30 + 0.015
100 Ω 1 mA ~ 80 mA 12 + 0.015 20 + 0.015 25 + 0.015
300 Ω 1 mA ~ 40 mA 12 + 0.02 20 + 0.02 25 + 0.02
1 kΩ 1 mA ~ 20 mA 12 + 0.02 20 + 0.02 25 + 0.02
3 kΩ 0.1 mA ~ 6 mA 12 + 0.2 20 + 0.2 25 + 0.2
10 kΩ 0.1 mA ~ 2 mA 12 + 0.2 20 + 0.2 25 + 0.2
30 kΩ 10 μA ~ 600 μA 15 + 1 24 + 1 30 + 1
100 kΩ 10 μA ~200 μA 15 + 1 24 + 1 30 + 1
300 kΩ 1 μA ~ 60 μA 17 + 10 28 + 10 35 + 10
1 MΩ 1 μA ~ 20 μA 17 + 10 28 + 10 35 + 10
3 MΩ 250 nA ~ 6 μA 30 + 150 48 + 150 60 + 150
10 MΩ 250 nA ~ 2 μA 65 + 250 104 + 250 130 + 250
30 MΩ 25 nA ~ 600 nA 125 + 2.5 k 200 + 2.5 k 250 + 2.5 k
100 MΩ 25 nA ~ 200 nA 250 + 3 k 400 + 3 k 500 + 3 k
300 MΩ 2.5 nA ~ 60 nA 1,5 k + 0.1 M 2.4 k + 0.1 M 3 k + 0.1 M
1000 MΩ 1 nA ~ 20 nA 7.5 k + 0.5 M 12 k + 0.5 M 15 k + 0.5 M
  • Output Range of Resistance: 0 Ω ~ 1100 MΩ; Resolution: 0.0004 %*RG; Display: 7 digits

Thermal Resistance (RTD)

Type Temperature Range (°C) Accuracy (k = 2) (°C)
90 Days 1 Year
Pt385, 100 Ω -200 ~ 0 0.05 0.05
0 ~ 300 0.08 0.08
300 ~ 850 0.12 0.12
Pt385,200 Ω -200 ~ 250 0.04 0.04
250 ~ 630 0.10 0.15
Pt385,500 Ω -200 ~ -30 0.36 0.40
-30 ~ 630 0.10 0.11
Pt385,1000 Ω -200 ~ 0 0.027 0.03
0 ~ 300 0.054 0.060
300 ~ 600 0.063 0.070
CU50 -50 ~ 150 0.09 0.09
CU100 -50 ~ 150 0.045 0.045

Thermocouple (TC)

Type Temperature Range (°C) Accuracy (k = 2) (°C)
90 Days 1 Year
B 410 ~ 600 0.30 0.35
600 ~ 900 0.30 0.31
900 ~ 1800 0.26 0.30
E -200 ~ 0 0.10 0.11
0 ~ 600 0.07 0.08
600 ~ 1000 0.09 0.10
J -200 ~ -100 0.12 0.13
-100 ~ 750 0.09 0.09
750 ~ 1200 0.10 0.10
K -200 ~ -100 0.15 0.20
-100 ~ 1000 0.10 0.10
1000 ~ 1370 0.12 0.12
N -200 ~ -100 0.20 0.25
-100 ~ 400 0.12 0.12
400 ~ 1300 0.10 0.12
R -50 ~ 50 0.30 0.40
50 ~ 300 0.28 0.32
300 ~ 1000 0.22 0.23
1000 ~ 1750 0.25 0.25
S -50 ~ 50 0.30 0.40
50 ~ 300 0.31 0.34
300 ~ 1000 0.24 0.24
1000 ~ 1750 0.22 0.23
T -200 ~ -100 0.17 0.25
-100 ~ 0 0.08 0.11
0 ~ 400 0.08 0.08

Pulse

  • Frequency Range: 1 Hz ~ 2 MHz, TTL Level

  • Resolution: 0.001 %*RG

  • Accuracy: ±(0.002 %*RD + 20 μHz)

  • Jitter: <20 ns

DC Small Signal Measurement (Option)

  • Range: 1 V, 10 V, 2 mA, 20 mA

  • Measuring Range: ± (0 ~12 V);± (0 ~ 24 mA)

  • Accuracy: ±(0.006 %*RD + 0.004 %*RG)

  • Notes: Applied to measure the secondary DC signal of the transmitters.

China High Precision Fluke Multifunction Calibrator TD1880 For Electrical Measuring supplier

High Precision Fluke Multifunction Calibrator TD1880 For Electrical Measuring

Inquiry Cart 0