Environment-Friendly HFC227ea Fire Extinguishing System With UL Certification

Brand Name:Air Giant
Certification:UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
Model Number:AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Minimum Order Quantity:1 set
Delivery Time:10-15 working days
Payment Terms:L/C, D/P, T/T, Western Union, Paypal, Credit card
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
Supplier`s last login times: within 12 hours
Product Details Company Profile
Product Details

Environment-Friendly HFC227ea Fire Extinguishing System With UL Certification


Description of UL FM200 Fire Extinguishing System


The HFC-227EA automatic fire extinguishing system is an excellent fire extinguishing system because it responds quickly and does not produce any toxic consequences. Its design purpose is to extinguish Class A, B, and C fires. This type of system is very safe and can be discharged around humans without worrying about harmful chemicals in the discharge agent.


One of the most environmentally friendly systems is the HFC227EA Clean Agent Suppression System. By physically cooling the fire by eliminating the heat energy that interrupts the combustion cycle, it prevents the fire from being able to sustain itself. With the 227 system, UL certified HFC227ea disinfectant gas provides safe fire protection for people, property and life stock. The most challenging aspect of the use of environmentally friendly suppression agents is that they can affect the ozone layer, but the HFC227EA system is completely echo friendly and is not a depleting ozone suppression agent, although sometimes the fumes produced by fighting fires can affect the ozone layer.




Main Parameter of UL GB series cylinders


Model No.Nominal pressure (bar)Nominal volume(L)Filling volume (kg)

Caliber

(mm)

Weight

(kg)

Min.Max.
AG227SP-25-40M254019.244.84947
AG227SP-25-50M255024.056.04958
AG227SP-25-60M256028.867.24965
AG227SP-25-70M257033.678.44972
AG227SP-25-80M258038.489.64980
AG227SP-25-90M259043.2100.84994
AG227SP-25-100M2510048.0112.049100
AG227SP-25-120M2512057.6134.449113
AG227SP-25-150M2515072.0168.049134
AG227SP-25-40K254019.244.83341
AG227SP-25-50K255024.056.03352
AG227SP-25-60K256028.867.23359
AG227SP-42-40M424019.244.84947
AG227SP-42-50M425024.056.04958
AG227SP-42-60M426028.867.24965
AG227SP-42-70M427033.678.44972
AG227SP-42-80M428038.489.64980
AG227SP-42-90M429043.2100.84994
AG227SP-42-100M4210048.0112.049100
AG227SP-42-120M4212057.6134.449113
AG227SP-42-150M4215072.0168.049134
AG227SP-42-170M4217081.6190.449149
AG227SP-42-40K424019.244.83341
AG227SP-42-50K425024.056.03352
AG227SP-42-60K426028.867.23359



Features of UL FM200 Fire Extinguishing System


In tests, the acute toxicity of HFC-227EA Agent was shown to be equivalent to that of Halon 1301. HFC-227EA Agent has been evaluated for cardiac sensitization through test protocols approved by the US EPA. The EPA’s SNAP Program classifies HFC-227EA Agent as acceptable for use as a total flooding agent in occupied spaces.

HFC-227EA Agent is clean, leaves no residue, thereby eliminating costly after-fire clean-up, and keeping expensive “down-time” to a minimum. Most materials such as steel, stainless steel, aluminum, brass, and other metals as well as plastics ,rubber and electronic components are unaffected by exposure to HFC-227EA (FM200) Agent.




Application of UL FM200 Fire Extinguishing System


In usual commercial or industrial settings, HFC227ea may be applied for fire suppression systems. This system can be used to protect typical areas, such as: Bank strong room Libraries Bookstores Electronic data processing center Telephone switching studio Communication center Transformer and switchgear room Control room Test lab Inflammable liquid storage room




Packages of UL FM200 Fire Extinguishing System


We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


China Environment-Friendly HFC227ea Fire Extinguishing System With UL Certification supplier

Environment-Friendly HFC227ea Fire Extinguishing System With UL Certification

Inquiry Cart 0