Red Fire Extinguishing System For Anechoic Chamber Non Corrosive HFC227ea

Brand Name:Air Giant
Certification:UL(Urldorwri1er Laboratories Irlc);TPED;GB;DOT
Model Number:AG227SP-16.6;AG227SP-28.3;AG227SP-40;AG227SP-49;AG227SP-52;AG227SP-50;AG227SP-60;AG227SP-70;AG227SP-80;AG227SP-90;AG227SP-100;AG227SP-120;AG227SP-150;AG227SP-103;AG227SP-147;AG227SP-153;AG227SP-160;AG227SP-170
Minimum Order Quantity:1 set
Delivery Time:10-15 working days
Payment Terms:L/C, D/P, T/T, Western Union, Paypal, Credit card
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
Supplier`s last login times: within 12 hours
Product Details Company Profile
Product Details

UL Fire Extinguishing System Without A Residue For Anechoic Chamber Non Corrosive HFC227ea

Description of UL FM200 Fire Suppression System

HFC-227ea gas fire extinguishing device usually includes components such as fire extinguishing agent cylinder group (fire extinguishing agent steel cylinder, cylinder head valve), starter (gas starter, electromagnetic starter, manual starter), release hose, one-way valve, low discharge high seal valve, manifold, manifold safety valve, selection valve, drive cylinder group, release pressure switch, nozzle, fire extinguishing agent delivery pipeline, etc. HFC-227ea gas fire extinguishing devices can be divided into single zone systems and multi zone systems based on the number of protected areas, namely unit independent systems and combined distribution systems.


For a single zone system, after receiving a command from the gas fire extinguishing control panel, the electromagnetic starter opens the bottle head valve (i.e. the active bottle), and the active bottle starts to spray. The gas from the active bottle passes through the starting hose, and opens the bottle head valves (i.e. the driven bottle) of other connected fire extinguishing agent bottle groups, and all gas cylinders start to spray. The extinguishing agent is transported along the pipeline to the protected area and sprayed through nozzles.



Attributes of UL TPED series cylinders

Model No.Nominal pressure (bar)Nominal volume(L)Filling volume (kg)

Caliber

(mm)

Weight

(kg)

Min.Max.
AG227SP-25-40D254019.244.84942
AG227SP-25-50D255024.056.04948
AG227SP-25-60D256028.867.24953
AG227SP-25-70D257033.678.44959
AG227SP-25-80D258038.489.64964
AG227SP-25-90D259043.2100.84973
AG227SP-25-100D2510048.0112.04978
AG227SP-25-120D2512057.6134.44989
AG227SP-25-150D2515072.0168.049105
AG227SP-25-160D2516076.8179.249104
AG227SP-25-16.6C2516.68.018.63321
AG227SP-25-28.3C2528.313.631.73329
AG227SP-25-40C254019.244.83337
AG227SP-25-50C255024.056.03342
AG227SP-25-60C256028.867.23347
AG227SP-42-40D424019.244.84942
AG227SP-42-50D425024.056.04948
AG227SP-42-60D426028.867.24953
AG227SP-42-70D427033.678.44959
AG227SP-42-80D428038.489.64964
AG227SP-42-90D429043.2100.84973
AG227SP-42-100D4210048.0112.04978
AG227SP-42-120D4212057.6134.44989
AG227SP-42-150D4215072.0168.049105
AG227SP-42-160D4216076.8179.249104
AG227SP-42-170D4217081.6190.449108
AG227SP-42-16.6C4216.68.018.63321
AG227SP-42-28.3C4228.313.631.73329
AG227SP-42-40C424019.244.83337
AG227SP-42-50C425024.056.03342
AG227SP-42-60C426028.867.23347



Features of UL FM200 Fire Suppression System

1. The required concentration is low, which has little visual impact on on-site personnel and reduces personnel risk.

The 2 system has a relatively low usage, which can minimize overvoltage in the protection zone and maintain the structural safety of the protection zone.

3. Low toxicity and relatively safe for personnel.

Short spraying time and fast extinguishing speed are beneficial for reducing fire losses.

As long as the concentration level is maintained, it can effectively prevent reignition.


Application of UL FM200 Fire Suppression System

  • In usual commercial or industrial settings, HFC227ea may be applied for fire suppression systems. This system can be used to protect typical areas, such as: Bank strong room Libraries Bookstores Electronic data processing center Telephone switching studio Communication center Transformer and switchgear room Control room Test lab Inflammable liquid storage room


Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

China Red Fire Extinguishing System For Anechoic Chamber Non Corrosive HFC227ea supplier

Red Fire Extinguishing System For Anechoic Chamber Non Corrosive HFC227ea