DC24V 1.6A Carbon Dioxide Fire Suppression Co2 Fire Extinguisher For Server Room

DC24V 1.6A Carbon Dioxide Fire Suppression Co2 Fire Extinguisher For Server Room

Brand Name:Air Giant
Certification:CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number:QME70
Minimum Order Quantity:1 set
Delivery Time:10-15 working days
Payment Terms:L/C , D/P, T/T, Western Union, Paypal, Credit card
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
Supplier`s last login times: within 12 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Environment-Friendly CO2 Fire Extinguishing System For Server Room


Description


Pressurized CO2 fire suppression system is a kind of intelligent automatic fire extinguishing equipment, which uses pressurized CO2 as extinguishing agent. Pressurized CO2 extinguishing agent won’t cause damage for most things, because of its no residue and non-toxic after extinguishing. This agent still have many advantages: insulating, no water damage and good extinguishing effect.

Depend on different requirements of protection zone, pressurized CO2 fire suppression system can be designed as two kinds of the systems: unit system for single zone; combined distribution system for multiple zones. Adopts enclosed flooding extinguishing to realize the fire protection for single protected zone or multiple protected zones. Our system has three mode of starting: automatic, manual and machine emergency control. The system is advanced technology, high extinguishing efficiency and convenient maintenance.


Parameters


No.SpecificationTechnical Parameter
1Device ModelQME70
2Capacity70Ltr
3Filling Volume of Gas42kg
4Working Pressure5.7MPa
5Max Working Pressure12.4MPa
6Spraying Time≤60s
7Max Filling Rate0.6kg/L
8PowerDC24V/1.6A
9Working Pressure of Releasing Device

Container Valve: 19±0.95MPa;

Manifold: 15±0.75MPa

10Nitrogen Pressure of Driving6.0±1.0Mpa(20℃)
11Condition of Reserving Room for ContainerTemperature: 0~50℃

Application


It is suitable for putting out all kinds of the fires of flammable liquid and solid matter; gas fire in which power can be cut off before extinguishing the fire.

-paint-spraying room

-electronic computer room

-telecommunication room

-archives room

-boiler room

-control center

-hangar

-garage

-library