Product Details
  • XLPE insulated overhead insulated cable 1k V
  • Application

This product is suitable for overhead power lines with AC rated voltage of 10kV and below.

  • Cable Performance

The long-term allowable operating temperature of the cable shall not exceed 90℃.

Cable bending radius: cable outer diameter (D) less than 25mm, shall not be less than 4D; cable outer diameter (D) greater than 25mm, shall not be less than 6D.

  • See Table 1 for the cable model and name

Table 1

modelname
JKYJCopper-core xLPE insulated overhead insulated cable
JKTRYJSoft copper core xLPE insulated overhead insulated cable
JKLYJAluminum coreXLPE insulated overhead insulated cable
  • The structure and technical parameters of 1kV overhead insulated cable are shown in Table 2 and Table 3

Table 2, JKYJ 1kV JKTRYJ 1kV

nominal cross

(mm2)

The minimum number of conductorsOuter diameter of the conductor (reference value)

Insulation nominal thickness

(mm)

Average cable D maximum (mm)

20℃ conductor DC resistance

Not over (Ω / km)

90℃ Minimum insulation resistance

(MΩ •km)

Cable pull-off force

N

Hard copper coreSoft copper coreHard copper core
1063.81.06.51.9061.830.673471
1664.81.28.01.1981.150.655486
2566.01.29.40.7490.7270.548465
3567.01.411.00.5400.5240.5411731
5068.41.412.30.3990.3870.4616502
701210.01.414.10.2760.2680.4023461
951511.61.616.50.1990.1930.3931759
1201813.01.618.10.1580.1530.3539911
1501814.61.820.20.1280.1240.3549505
1853016.22.022.50.10210.09910.3561846
2403418.42.225.60.07770.07540.3479823

Table 3, JKLYJ 1kV

nominal cross

(mm2)

The minimum number of conductorsOuter diameter of the conductor (reference value)

Insulation nominal thickness

(mm)

Average cable D maximum (mm)

20℃ conductor DC resistance

Not over

(Ω/km)

90℃ Minimum insulation resistance

(MΩ •km)

Cable pull-off force

N

1063.81.06.53.080.671650
1664.81.28.01.910.652517
2566.01.29.41.200.543762
3567.01.411.00.8680.545177
5068.41.412.30.6410.467011
701210.01.414.10.4430.4010354
951511.61.616.50.3200.3913727
1201513.01.618.10.2530.3517339
1501514.61.820.20.2060.3521033
1853016.22.022.50.1640.3526732
2403018.42.225.60.1250.3434679
3003020.62.227.20.1000.3343349
4005323.22.230.70.07780.3255707

China Power Line Overhead Insulated Cable AC Rated 25mm Outer Diameter  1kv supplier