High Frequency UPS Battery Backup Modular 500KVA 40 - 70Hz Input Frequency

Brand Name:LIRUISI
Model Number:N500KVA
Minimum Order Quantity:1 set
Delivery Time:8 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Liruisi Industrial Park, No. 56 Fengtang Avenue, Shajing, Bao'an District, Shenzhen, Guangdong Province, China
Supplier`s last login times: within 8 hours
Product Details Company Profile
Product Details

Product introduction:

LIRUISI's N series three-in, three-out UPS adopts modular design and N+X parallel redundancy technology, and the product capacity covers each power segment between 50kVA and 600kVA, which is convenient for users to flexibly configure and gradually invest. This series of UPS can almost completely solve all power supply problems, such as power failure, mains high voltage, mains low voltage, voltage instantaneous drop, amplitude reduction oscillation, high voltage pulse, voltage fluctuation, surge voltage, harmonic distortion, clutter interference, frequency fluctuation and other power supplies.


way of working:

Three-in, three-out/three-in, single-out, double-conversion online work modular model operation.


Modular ups uninterruptible power supply features:

Efficiency: The modular high-frequency UPS has high conversion efficiency, which can convert the input AC energy into high-quality DC energy and stabilize it for output to load. This helps reduce energy consumption and improve device operation efficiency.


N50KVA-N600KVA【Modular HF UPS System】
ModelN500KVA
rated capacitycabinet50k-500k /
(VA/W)50k-500k /
module50k / 50k
(VA/W)
Maximum module10
quantity
N50KVA-N600KVA [modular high-frequency UPS system] technical parameters
UPS inputRated input voltage (Vac)380/400/415
Input voltage range (Vac)138~485Vac; 305~485Vac does not derate, 138~305Vac linear derating
Wiring systemThree-phase five-wire
Input frequency range (Hz)40-70
Input power factor≥0.99
Input current harmonics (THDi)≤ 3% (100% linear load)
bypass inputRated input voltage (Vac)380/400/415
Input voltage range (Vac)220 Limit: 25% (optional +10%, +15%, +20%) 230 Upper limit: 20% (optional +10%, +15%)240 Upper Limit: 15% (optional +10%) Lower limit: -45% (optional -10%, -20%, -30%)
Wiring systemThree-phase five-wire
Bypass sync tracking range (Hz)±10%
UPS outputOutput voltage (Vac)380/400/415±1%
power factor1
overload capacity110% load, turn bypass after 60min; 125% load, turn bypass after 10min; 150% load, for 1 min and then turn to bypass
Switch time (ms)0
batterybattery voltage±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc (Section 30/32/34/36/38/40/42/44/46/48/50); (30 knots ~ 50 knots optional, default 36 knots, 36 knots and 50 knots output power is not derating; Output power derating to 0.9 at 32 and 34 cells, 0.8 output power at 30 cells)
sizeUPS cabinet1200×850×2000
module440×620×130
weightUPS cabinet380
module33
China High Frequency UPS Battery Backup Modular 500KVA 40 - 70Hz Input Frequency supplier